In-Situ AFM and EIS Study of Waterborne Acrylic Latex Coatings for Corrosion Protection of Carbon Steel

被引:25
|
作者
Li, Jing [1 ]
Ecco, Luiz [2 ]
Delmas, Gregory [3 ]
Whitehouse, Nigel [4 ]
Collins, Peter [4 ]
Deflorian, Flavio [2 ]
Pan, Jinshan [1 ]
机构
[1] KTH Royal Inst Technol, Sch Chem Sci & Engn, Div Surface & Corros Sci, Stockholm, Sweden
[2] Univ Trento, Dept Ind Engn, I-38123 Trento, Italy
[3] Arkema Coating Resins, Verneuil En Halatte, France
[4] PRA, Hampton, Middx, England
关键词
FILM FORMATION; CROSS-LINKING; NETWORK STRUCTURE; POLYANILINE; PERFORMANCE; RESISTANCE; STABILITY; PAINT; POLYPYRROLE; POLYSTYRENE;
D O I
10.1149/2.0851501jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Corrosion protection for carbon steel by three waterborne styrene-acrylic latex coatings with different glass transition temperature (Tg) and levels of hydrophobicity has been studied by in-situ atomic force microscope (AFM) and electrochemical impedance spectroscopy (EIS) measurements in 3.0 wt% NaCl solution. The AFM images reveal the micro-and nano-structure of and pinholes in the coatings as well as their changes during exposure in the solution, whereas the EIS spectra vs. time of exposure show the barrier property, stability and degradation of the coatings. The coating with crosslinking and high level of hydrophobicity exhibited a high barrier property and long-term corrosion protection in the solution despite of some shallow pinholes. The coating without crosslinking but having high Tg and high level of hydrophobicity also displayed a high barrier property and certain stability although initial changes occur in the solution. However, for the coating without crosslinking and with low Tg and relative low level of hydrophobicity, some dissolution and open-up of defects occurred on the surface shortly after exposure and the coating lost its barrier property rapidly in the solution. The reasons for the different behaviors between the coatings are discussed with respect to the crosslinking, Tg and the hydrophobicity level of the coating. (C) The Author(s) 2014. Published by ECS. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 License (CC BY, http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse of the work in any medium, provided the original work is properly cited. All rights reserved.
引用
收藏
页码:C55 / C63
页数:9
相关论文
共 50 条
  • [31] Enhanced Corrosion Protection of Polypyrrole Coatings on Carbon Steel via Electrodeposition
    Liu, Bailong
    Zhang, Zhaohui
    Wan, Jiangkai
    Liu, Shifeng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (02): : 994 - 1003
  • [32] Corrosion protection of carbon steel by polyurethane coatings containing graphene oxide
    Nguyen Thuy Duong
    Tran Boi An
    Phan Thanh Thao
    Vu Ke Oanh
    Trinh Anh Truc
    Pham Gia Vu
    To Thi Xuan Hang
    VIETNAM JOURNAL OF CHEMISTRY, 2020, 58 (01) : 108 - 112
  • [33] Polyaniline/polyvinyl chloride blended coatings for the corrosion protection of carbon steel
    Bandeira, Rafael Marinho
    van Drunen, Julia
    Tremiliosi-Filho, Germano
    dos Santos Junior, Jose Ribeiro
    Elias de Matos, Jose Milton
    PROGRESS IN ORGANIC COATINGS, 2017, 106 : 50 - 59
  • [34] In-situ grafted graphene oxide-based waterborne epoxy curing agent for reinforcement corrosion protection of waterborne epoxy coating
    Zhou, Tao
    Zhang, Jin
    Zhao, Jianguo
    Qu, Wenshan
    Li, Xinyu
    Li, Shijie
    Xing, Baoyan
    Fu, Yongchun
    SURFACE & COATINGS TECHNOLOGY, 2021, 412
  • [35] A study on corrosion protection of different polyaniline coatings for mild steel
    Zhang, Yingjun
    Shao, Yawei
    Liu, Xiaoling
    Shi, Chao
    Wang, Yanqiu
    Meng, Guozhe
    Zeng, Xianguang
    Yang, Yan
    PROGRESS IN ORGANIC COATINGS, 2017, 111 : 240 - 247
  • [36] On the localised corrosion of carbon steel induced by the in-situ local damage of porous corrosion products
    Pang, Lin
    Wang, Zhengbin
    Zheng, Yugui
    Lai, Xueming
    Han, Xu
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2020, 54 : 95 - 104
  • [37] On the localised corrosion of carbon steel induced by the in-situ local damage of porous corrosion products
    Lin Pang
    Zhengbin Wang
    Yugui Zheng
    Xueming Lai
    Xu Han
    Journal of Materials Science & Technology, 2020, 54 (19) : 95 - 104
  • [38] Enhanced Protective Performance of Carbon Nanotube-Reinforced Waterborne Epoxy Zinc-Rich Coatings for Corrosion Protection of Steel Structures
    Huang, Xueling
    Yang, Chun
    Chen, Junyu
    Qiao, Xinglong
    Zhang, Shuguang
    Song, Dan
    COATINGS, 2024, 14 (12):
  • [39] Evaluation of the corrosion protection performance of epoxy coatings containing Mg nanoparticle on carbon steel in 0.1 M NaCl solution by SECM and EIS techniques
    Joseph Raj Xavier
    Toshiyasu Nishimura
    Journal of Coatings Technology and Research, 2017, 14 : 395 - 406
  • [40] EIS study on the corrosion behavior of rusted carbon steel in 3% NaCl solution
    Hu, Jiayuan
    Cao, Shun-an
    Xie, Jianli
    ANTI-CORROSION METHODS AND MATERIALS, 2013, 60 (02) : 100 - 105