Influence of training on dorsal tangential radiographic view to detect screw protrusion after anterior plating of the distal radius: a cadaveric study

被引:1
|
作者
Bergsma, Minke [1 ,2 ,3 ,4 ,5 ,6 ]
Obdeijn, Miryam C. [4 ,5 ,6 ]
Janssen, Stein J. [7 ]
Bain, Gregory, I [1 ,2 ,3 ]
Jaarsma, Ruurd L. [1 ,2 ,3 ]
Doornberg, Job N. [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Flinders Med Ctr, Dept Orthopaed Surg, Adelaide, SA, Australia
[2] Flinders Univ S Australia, Dept Orthopaed Trauma Surg, Adelaide, SA, Australia
[3] Flinders Univ S Australia, Biomech & Implants Res Grp, Adelaide, SA, Australia
[4] Univ Amsterdam, Med Ctr, Dept Orthopaed Surg, Amsterdam, Netherlands
[5] Univ Amsterdam, Med Ctr, Dept Plast Reconstruct & Hand Surg, Amsterdam, Netherlands
[6] Univ Amsterdam, Amsterdam, Netherlands
[7] Amphia Hosp, Dept Orthopaed Surg, Breda, Netherlands
关键词
Dorsal screw penetration; dorsal tangential view; distal radius fractures; volar plating; training; INTERNAL-FIXATION; PENETRATION; FRACTURES; RELIABILITY; AGREEMENT; ULTRASOUND; SYSTEM; IMPACT; TENDON; CORTEX;
D O I
10.1177/1753193419898060
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In this cadaveric study of anterior plating of the distal radius, we aimed to determine the interobserver agreement and diagnostic performance for detecting dorsally protruding screws using the dorsal tangential radiographic view before and after specific training. Without prior instruction, 13 observers interpreted the dorsal tangential view of cadaveric specimens, in which anterior radial plates were placed. After seeing a training video on the dorsal tangential view, they repeated the task. Though we found that accuracy and interobserver agreement was lower than described in some other clinical series, training led to statistically significant improvements of (1) the interobserver agreement on the decision to exchange screws, (2) the self-confidence of the surgeon in obtaining adequate views, and (3) the number of fluoroscopic images required to obtain these views. After training, the number of protruding screws missed was reduced by 36%, but 7% of dorsally protruding screws was still missed.
引用
收藏
页码:864 / 870
页数:7
相关论文
共 22 条
  • [11] Influence of screw diameter and number on reduction loss after plating of distal radius fractures
    Drobetz, Herwig
    Schueller, Michael
    Tschegg, Elmar Karl
    Heal, Clare
    Redl, Heinz
    Muller, Reinhold
    ANZ JOURNAL OF SURGERY, 2011, 81 (1-2) : 46 - 51
  • [12] Comparison of 4 Fluoroscopic Views for Dorsal Cortex Screw Penetration After Volar Plating of the Distal Radius
    Ozer, Kagan
    Wolf, Jennifer M.
    Watkins, Bruce
    Hak, David J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05): : 963 - 967
  • [13] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Haug, Luzian C. P.
    Deml, Christian
    Blauth, Michael
    Arora, Rohit
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1279 - 1282
  • [14] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Luzian C. P. Haug
    Christian Deml
    Michael Blauth
    Rohit Arora
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1279 - 1282
  • [15] Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
    Rausch, Sascha
    Marintschev, Ivan
    Graul, Isabel
    Wilharm, Arne
    Klos, Kajetan
    Hofmann, Gunther O.
    Gras, Marc Florian
    ARCHIVES OF TRAUMA RESEARCH, 2015, 4 (02)
  • [16] Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study
    Williams, D.
    Singh, J.
    Heidari, N.
    Ahmad, M.
    Noorani, A.
    Di Mascio, L.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (02) : 138 - 142
  • [17] Fluoroscopic Evaluation of Intra-Articular Screw Placement During Locked Volar Plating of the Distal Radius: A Cadaveric Study
    Soong, Maximillian
    Got, Christopher
    Katarincic, Julia
    Akelman, Edward
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (10): : 1720 - 1723
  • [18] Diagnosis of dorsal screw penetration after volar plating of a distal radial fracture INTRAOPERATIVE DORSAL TANGENTIAL VIEWS VERSUS 3D FLUOROSCOPY
    Langerhuizen, D. W. G.
    Bergsma, M.
    Selles, C. A.
    Jaarsma, R. L.
    Goslings, J. C.
    Schep, N. W. L.
    Doornberg, J. N.
    BONE & JOINT JOURNAL, 2020, 102B (07): : 874 - 880
  • [19] The 70° Supinated Oblique View: A Cadaveric Analysis to Determine Ideal Radial Styloid Screw Position in Locked Volar Plating of Distal Radius Fractures
    Sumner, Kirsten
    Grandizio, Louis C.
    Schultz, Samantha
    Klena, Joel C.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (01): : 99 - 103
  • [20] Skyline view versus intraoperative 3D fluoroscopy for dorsal screw protrusion identification following volar plating in the treatment of distal radial fracture
    Chih-Hsuan Wung
    Wen-Chih Liu
    Lucía Chiquiar
    Jesse B. Jupiter
    Pietro Regazzoni
    Alberto A. Fernández dell’Oca
    Journal of Orthopaedic Surgery and Research, 20 (1)