Exploring Cherenkov Emission of BGO for TOF-PET

被引:35
|
作者
Kratochwil, Nicolaus [1 ,2 ]
Auffray, Etiennette [1 ]
Gundacker, Stefan [1 ,3 ,4 ]
机构
[1] CERN, Dept EP CMX, CH-1211 Meyrin, Switzerland
[2] Univ Vienna, A-1010 Vienna, Austria
[3] UniMIB, I-20126 Milan, Italy
[4] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, D-52074 Aachen, Germany
关键词
Cherenkov emission in Bismuth germanate (BGO); scintillators; semiconductors; signal processing; time-of-flight (TOF) positron emission tomography (PET); TIME; SCINTILLATORS; RISE;
D O I
10.1109/TRPMS.2020.3030483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bismuth germanate (BGO) was the preferred crystal for positron emission tomography (PET) scanners, but was substituted with the emergence of faster crystals. Improvements in silicon photomultipliers (SiPMs) and the use of fast high frequency readout make it possible to use the prompt Cherenkov emission in BGO in order to boost the achievable coincidence time resolution (CTR) significantly. The large fluctuations in the detected Cherenkov photon yield are causing time or amplitude walk effects in the leading edge time discrimination, which are corrected by measuring the initial signal rise time via a double threshold system. Further a classification of "fast" and "slow" timing events is shown to make best use of all the information and upgrades the CTR for most of the 511-keV events. In order to assess the practicability of this novel approach various crystal geometries and state-of-the-art SiPMs from HPK, Ketek, Broadcom, and FBK have been evaluated with the focus on the applicability in total body PET systems. For typical PET sized crystals (3 x 3 x 20 mm(3)) coupled to area matching 3 x 3-mm(2) Broadcom SiPMs a time resolution of 261 +/- 8 ps full width at half maximum (FWHM) was measured when applying time walk corrections, while the CTR of individual types of events with different Cherenkov yield range from 205 to 302-ps FWHM. A further thorough discussion and prospects of TOF-PET with BGO are given, especially in view of timing event classification of all detected 511-keV events, corresponding to various time of flight kernels ranging from high to low time resolution.
引用
收藏
页码:619 / 629
页数:11
相关论文
共 50 条
  • [21] Determining timing resolution from TOF-PET emission data
    Vandenberghe, S.
    Matej, S.
    Daube-Witherspoon, M. E.
    Guerchaft, M.
    Verhaeghe, J.
    Bol, A.
    van Elmbt, L.
    Lemahieu, I.
    Karp, J. S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2727 - +
  • [22] Study of TOF-PET Performance
    Takeshita, Tohru
    Yamazaki, Makoto
    Hasegawa, Yoji
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1461 - 1465
  • [23] Exploring the Potential of a Cherenkov TOF PET Scanner: A Simulation Study
    Razdevsek, G.
    Pestotnik, R.
    Krizan, P.
    Korpar, S.
    Consuegra, D.
    Seljak, A.
    Studen, A.
    Dolenec, R.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (01) : 52 - 61
  • [24] Study of Cerenkov Light Emission in the Semiconductors TlBr and TlCl for TOF-PET
    Arino-Estrada, Gerard
    Roncali, Emilie
    Selfridge, Aaron R.
    Du, Junwei
    Glodo, Jaroslaw
    Shah, Kanai S.
    Cherry, Simon R.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (05) : 630 - 637
  • [25] Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET
    Cates, Joshua W.
    Choong, Woon-Seng
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19):
  • [26] Development of the FTM technology for TOF-PET
    Radogna, R.
    Verwilligen, P.
    Maggi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 (449-450): : 449 - 450
  • [27] Estimation of crystal timings in TOF-PET
    Rezaei, Ahmadreza
    Schramm, Georg
    Van Laere, Koen
    Nuyts, Johan
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [28] A TOF-PET system for educational purposes
    Bäck, T
    Cederkäll, J
    Cederwall, B
    Johnson, A
    Kerek, A
    Klamra, W
    van der Marel, J
    Molnár, J
    Novák, D
    Sohler, D
    Steén, M
    Uhlén, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 82 - 87
  • [29] New approaches for improvement of TOF-PET
    Brunner, S. E.
    Gruber, L.
    Marton, J.
    Suzuki, K.
    Hirtl, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 560 - 563
  • [30] Fast Timing MPGD for ToF-PET
    Errico, F.
    Colaleo, A.
    Maggi, M.
    Pellecchia, A.
    Radogna, R.
    Verwilligen, P. O. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042