Direct electron transfer of hemoglobin on dihexadecyl hydrogen phosphate/single-wall carbon nanotubes film modified Au electrode and its interaction with taxol

被引:1
|
作者
Zhang, Y. Z. [1 ]
Cheng, W. X. [1 ]
Li, S. P. [1 ]
机构
[1] Anhui Normal Univ, Wuhan 241000, Peoples R China
关键词
hemoglobin; single-wall carbon nanotube; dihexadecyl hydrogen phosphate; taxol; SURFACTANT FILMS; ELECTROCHEMICAL-BEHAVIOR; CATALYTIC-REDUCTION; ENZYMATIC-ACTIVITY; GOLD ELECTRODE; HEME-PROTEINS; MYOGLOBIN; NANOPARTICLES; VOLTAMMETRY; OXIDATION;
D O I
10.1134/S102319350707004X
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Direct electrochemistry of hemoglobin (Hb) immobilized on the dihexadecyl hydrogen phosphate (DHP)/single-wall carbon nanotubes (SWNTs) film modified Au electrode is investigated. The immobilized Hb displays a couple of stable and well-defined redox peaks, whose formal potential (E-0) is -0.434 V (SCE) in a phosphate buffer solution of pH 7.0. The formal potential of the heme Fe(III)/Fe(II) couple shifts negatively linearly with increased pH with a slope of -42.3 mV/pH, denoting that one electron transfer accompanies single proton transportation. Both SWNTs and DHP can accelerate the electron transfer between Hb and the electrode. Using DHP/Hb/SWNTs-film-modified Au electrode, the interaction between Hb and taxol is investigated. The voltammetric response of Hb decreases with increasing concentration of taxol. The peak currents decreases proportionally to the taxol concentration at 1.4 x 10(-5) to 1.3 x 10(-4)M, the linear regression equation being Delta (A) = 2.9603 - 0.4225 c(taxol) (M), with a correlation coefficient (r) 0.9985, and the detection limit 6.95 x 10(-6)M (signal-to-noise ratio of three).
引用
收藏
页码:764 / 769
页数:6
相关论文
共 50 条
  • [31] Electron-phonon interaction in single-wall carbon nanotubes: A time-domain study
    Hertel, T
    Moos, G
    PHYSICAL REVIEW LETTERS, 2000, 84 (21) : 5002 - 5005
  • [32] Electrochemical behaviors of lomefloxacin at a single-wall carbon nanotube-modified electrode and its interaction with bovine serum albumin
    XU MaotianKONG FenyingZHANG Yintang Department of ChemistryShangqiu Teachers CollegeShangqiu China
    商丘师范学院学报, 2009, 25 (12) : 46 - 53
  • [33] Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode
    Goyal, Rajendra N.
    Gupta, Vinod K.
    Chatterjee, Sanghamitra
    TALANTA, 2008, 76 (03) : 662 - 668
  • [34] Atomic force microscopic and electrochemical investigations of an electrostatically fabricated single-wall carbon nanotubes modified electrode
    Qu, XH
    Peng, ZQ
    Wang, YL
    Dong, SJ
    ELECTROANALYSIS, 2005, 17 (01) : 59 - 64
  • [35] Differential conductance of armchair single-wall carbon nanotubes due to presence of electron phonon interaction
    Tajik, Fatemeh
    Namiranian, Afshin
    PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2016, 84 : 79 - 83
  • [36] Dendrimer-functionalized single-wall carbon nanotubes: Synthesis, characterization, and photoinduced electron transfer
    Campidelli, Stephane
    Sooambar, Chloe
    Diz, Enrique Lozano
    Ehli, Christian
    Guldi, Dirk M.
    Prato, Maurizio
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (38) : 12544 - 12552
  • [37] Dendrimer-functionalized single-wall carbon nanotubes: Synthesis, characterization, and photoinduced electron transfer
    Campidelli, Stéphane
    Sooambar, Chloé
    Diz, Enrique Lozano
    Ehli, Christian
    Guldi, Dirk M.
    Prato, Maurizio
    Journal of the American Chemical Society, 2006, 128 (38): : 12544 - 12552
  • [38] Electrocatalytic oxidation of 3,4-dihydroxyphenylacetic acid at a glassy carbon electrode modified with single-wall carbon nanotubes
    Wang, JX
    Li, MX
    Shi, ZJ
    Li, NQ
    Gu, ZN
    ELECTROCHIMICA ACTA, 2001, 47 (04) : 651 - 657
  • [39] Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode
    Gu, HY
    Yu, AM
    Chen, HY
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2): : 119 - 126
  • [40] Direct Electron Transfer of Hemoglobin in a Hydrophilic Ionic Liquid/Gellan Gum Composite Film Modified Carbon Ionic Liquid Electrode
    Qiao, Li-Fang
    Zheng, Jian-Bin
    Gao, Rui-Fang
    Sheng, Qing-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (4A) : 718 - 725