Quantification of dynamic contrast-enhanced ultrasound (CEUS) in non-cystic breast lesions using external perfusion software

被引:25
|
作者
Jung, Ernst Michael [1 ]
Jung, Friedrich [2 ]
Stroszczynski, Christian [1 ]
Wiesinger, Isabel [1 ]
机构
[1] Univ Med Ctr, Interdisciplinary Dept Ultrasound, Inst Radiol, Franz Josef Str Allee 11, D-93053 Regensburg, Germany
[2] Brandenburg Tech Univ Cottbus, Inst Biotechnol Mol Cell Biol, Univ Pl 1, D-01968 Senftenberg, Germany
关键词
EFSUMB GUIDELINES; CLINICAL-PRACTICE; RECOMMENDATIONS; MRI; ULTRASONOGRAPHY; PERFORMANCE; BENIGN;
D O I
10.1038/s41598-021-96137-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this present clinical pilot study is the display of typical perfusion results in patients with solid, non-cystic breast lesions. The lesions were characterized using contrast enhanced ultrasound (CEUS) with (i) time intensity curve analyses (TIC) and (ii) parametric color maps. The 24 asymptomatic patients included were genetically tested for having an elevated risk for breast cancer. At a center of early detection of familial ovary and breast cancer, those patients received annual MRI and grey-scale ultrasound. If lesions remained unclear or appeared even suspicious, those patients also received CEUS. CEUS was performed after intravenous application of sulfur hexafluoride microbubbles. Digital DICOM cine loops were continuously stored for one minute in PACS (picture archiving and communication system). Perfusion images and TIC analyses were calculated off-line with external perfusion software (VueBox). The lesion diameter ranged between 7 and 15 mm (mean 11 +/- 3 mm). Five hypoechoic irregular lesions were scars, 6 lesions were benign and 12 lesions were highly suspicious for breast cancer with irregular enhancement at the margins and a partial wash out. In those 12 cases, histopathology confirmed breast cancer. All the suspicious lesions were correctly identified visually. For the perfusion analysis only Peak Enhancement (PE) and Area Under the Curve (AUC) added more information for correctly identifying the lesions. Typical for benign lesions is a prolonged contrast agent enhancement with lower PE and prolonged wash out, while scars are characterized typically by a reduced enhancement in the center. No differences (p = 0.428) were found in PE in the center of benign lesions (64.2 +/- 28.9 dB), malignant lesions (88.1 +/- 93.6 dB) and a scar (40.0 +/- 17.0 dB). No significant differences (p = 0.174) were found for PE values at the margin of benign lesions (96.4 +/- 144.9 dB), malignant lesions (54.3 +/- 86.2 dB) or scar tissue (203.8 +/- 218.9 dB). Significant differences (p < 0.001) were found in PE of the surrounding tissue when comparing benign lesions (33.6 +/- 25.2 dB) to malignant lesions (15.7 +/- 36.3 dB) and scars (277.2 +/- 199.9 dB). No differences (p = 0.821) were found in AUC in the center of benign lesions (391.3 +/- 213.7), malignant lesions (314.7 +/- 643.9) and a scar (213.1 +/- 124.5). No differences (p = 0.601) were found in AUC values of the margin of benign lesions (313.3 +/- 372.8), malignant lesions (272.6 +/- 566.4) or scar tissue (695.0 +/- 360.6). Significant differences (p < 0.01) were found in AUC of the surrounding tissue for benign lesions (151.7 +/- 127.8), malignant lesions (177.9 +/- 1345.6) and scars (1091 +/- 693.3). There were no differences in perfusion evaluation for mean transit time (mTT), rise time (RT) and time to peak (TTP) when comparing the center to the margins and the surrounding tissue. The CEUS perfusion parameters PE and AUC allow a very good assessment of the risk of malignant breast lesions and thus a downgrading of BI-RADS 4 lesions. The use of the external perfusion software (VueBox, Bracco, Milan, Italy) did not lead to any further improvement in the diagnosis of suspicious breast lesions and does appears not to have any additional diagnostic value in breast lesions.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Perfusion patterns of peripheral pulmonary lesions in COVID-19 patients using contrast-enhanced ultrasound (CEUS) A case series
    Zadeh, Ehsan Safai
    Beutel, Bjoern
    Dietrich, Christoph Frank
    Keber, Corinna Ulrike
    Huber, Katharina Paulina
    Goerg, Christian
    Trenker, Corinna
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (11) : 2403 - 2411
  • [22] Contrast-Enhanced Ultrasound (CEUS) of the Kidneys by Using the Bosniak Classification
    Ruebenthaler, J.
    Bogner, F.
    Reiser, M.
    Clevert, D. A.
    ULTRASCHALL IN DER MEDIZIN, 2016, 37 (03): : 234 - 248
  • [23] Comparison of transducers with different frequencies in breast contrast-enhanced ultrasound (CEUS) using SonoVue as contrast agent
    Wang, Yong-Mei
    Fan, Wei
    Zhang, Kai
    Zhang, Li
    Tan, Zhen
    Ma, Rong
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063):
  • [24] Contrast-enhanced ultrasound (CEUS) for the study of peripheral lung lesions: A preliminary study
    Sperandeo, Marco
    Sperandeo, Giuseppe
    Varriale, Antonio
    Filabozzi, Paola
    Decuzzi, Marco
    Dimitri, Lucia
    Vendemiale, Gianluigi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (10): : 1467 - 1472
  • [25] Dynamic contrast-enhanced endoscopic ultrasound: A quantification method
    Dietrich, Christoph F.
    Dong, Yi
    Froehlich, Eckhart
    Hocke, Michael
    ENDOSCOPIC ULTRASOUND, 2017, 6 (01) : 12 - 20
  • [26] Contrast-Enhanced Ultrasound (CEUS) in Non-Traumatic Abdominal Emergencies
    Cozzi, Diletta
    Agostini, Simone
    Bertelli, Elena
    Galluzzo, Michele
    Papa, Emanuela
    Scevola, Germano
    Trinci, Margherita
    Miele, Vittorio
    ULTRASOUND INTERNATIONAL OPEN, 2020, 06 (03) : E76 - E86
  • [27] Perfusion quantification using dynamic contrast-enhanced ultrasound: The impact of dynamic range and gain on time-intensity curves
    Gauthier, Thomas P.
    Averkiou, Michalakis A.
    Leen, Edward L. S.
    ULTRASONICS, 2011, 51 (01) : 102 - 106
  • [28] Imaging of Benign and Malignant Breast Lesions Using Contrast-Enhanced Ultrasound
    Lee, Sandy C.
    Tchelepi, Hisham
    Khadem, Nasim
    Desai, Bhushan
    Yamashita, Mary
    Hovanessian-Larsen, Linda
    ULTRASOUND QUARTERLY, 2022, 38 (01) : 2 - 12
  • [29] Differential diagnostic value of diffusion-weighted and dynamic contrast-enhanced MR imaging in non-cystic lesions in floor of the mouth
    Yuan, Ying
    Jiang, Mengda
    Wu, Lizhong
    Tao, Xiaofeng
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (03)
  • [30] Computerized segmentation and classification of breast lesions using perfusion volume fractions in dynamic contrast-enhanced MRI
    Lee, Sang Ho
    Kim, Jong Hyo
    Park, Jeong Seon
    Chang, Jung Min
    Park, Sang Joon
    Jung, Yun Sub
    Moon, Woo Kyung
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 58 - +