Air quality control in mine refuge chamber with ventilation through pressure air pipeline

被引:15
|
作者
Zhang, Zujing [1 ,2 ]
Wu, Hongwei [3 ]
Wang, Kequan [2 ]
Day, Rodney [3 ]
Yuan, Yanping [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Peoples R China
[2] China Coal Technol & Engn Grp, Chongqing Res Inst, Chongqing 400037, Peoples R China
[3] Univ Hertfordshire, Sch Engn & Comp Sci, Hatfield AL10 9AB, Herts, England
基金
中国国家自然科学基金;
关键词
Underground; Mine refuge chamber; Ventilation; CO2; concentration; Air quality; CARBON-DIOXIDE CONCENTRATION; NATURAL-CONVECTION; NUMERICAL-SIMULATION; TEMPERATURE; PERFORMANCE; CO2; ACCIDENTS; RESPONSES; HUMIDITY; EXPOSURE;
D O I
10.1016/j.psep.2019.12.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A combined experimental and numerical study was performed to improve the performance of the ventilation system in a mine refuge chamber (MRC). In the experiment, CO2 cylinders and dispersion pipes were used to simulate the CO2 release of 50 people, and 0.1 L/min per person of fresh air was provided by an air compressor. A new analytical model for a 50-person MRC was proposed and validated against the experimental data. Sensitivity analysis was carried out to investigate the effects of several control factors. The results indicated the following: (1) The ventilation system layout has a significant influence on the CO2 concentration distribution in an MRC, while the uniformity of the CO2 concentration distribution in the MRC may not be effective with increased number of air inlets. (2) Under a well-arranged ventilation system in the 50-person MRC, the average CO2 concentration can be controlled at less than 0.5 % with a ventilation rate of 0.1 m(3) /min per person, and less than 0.2 % with a ventilation rate of 0.3 m(3) /min per person. (3) A quantitative correlation exists between the CO2 concentration and ventilation volume rate, as well as the CO2 release rate, for an MRC under a well-arranged ventilation system. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 58
页数:13
相关论文
共 50 条
  • [21] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)
  • [22] AIR-QUALITY AND VENTILATION
    HUBER, G
    WANNER, HU
    SOZIAL-UND PRAVENTIVMEDIZIN, 1981, 26 (03): : 177 - 179
  • [23] Air Quality and Ventilation in Schools
    Neumann, H. -D.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2011, 71 (11-12): : 495 - 497
  • [24] Thermal performance of a mine refuge chamber with human body heat sources under ventilation
    Zhang, Zujing
    Wu, Hongwei
    Wang, Kequan
    Day, Rodney
    Yuan, Yanping
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [25] Ventilation control for improved cabin air quality and vehicle safety
    Galatsis, K
    Wlodarski, W
    Li, YX
    Kalantar-zadeh, K
    IEEE VTC 53RD VEHICULAR TECHNOLOGY CONFERENCE, SPRING 2001, VOLS 1-4, PROCEEDINGS, 2001, : 3018 - 3021
  • [26] Mine air distribution control
    Liu, CS
    PROCEEDINGS OF THE 6TH INTERNATIONAL MINE VENTILATION CONGRESS, 1997, : 403 - 406
  • [28] Air pressure chamber for lung operations
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1922, 66 : 525 - 525
  • [29] MINE WATER USED TO HEAT VENTILATION AIR AT HENDERSON MOLYBDENUM MINE
    JENSEN, EB
    MINING ENGINEERING, 1983, 35 (01) : 17 - 20
  • [30] AN UNDERGROUND MINE AIR-QUALITY LABORATORY FOR STUDYING VENTILATION, VEHICLE AND DIESEL-ENGINE POLLUTANT CONTROL TECHNIQUES
    KESKIHYNNILA, DE
    REINBOLD, EO
    JOHNSON, JH
    CIM BULLETIN, 1981, 74 (835): : 74 - 83