Intracranial aneurysms treated with Guglielmi detachable coils: Is contrast material necessary in the follow-up with 3D time-of-flight MR angiography?

被引:0
|
作者
Cottier, JP [1 ]
Bleuzen-Couthon, A [1 ]
Gallas, S [1 ]
Vinikoff-Sonier, CB [1 ]
Bertrand, P [1 ]
Domengie, F [1 ]
Barantin, L [1 ]
Herbreteau, D [1 ]
机构
[1] Hop Bretonneau, Dept Neuroradiol, F-37044 Tours 1, France
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Three-dimensional time-of-flight (TOF) MR angiography has been evaluated in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDCs) with good results. Some of the studies used contrast material in addition to the 3D TOF MR technique and others did not. We assessed the usefulness of contrast material with 3D TOF MR angiography by comparing this sequence before and after contrast material injection. METHODS: Fifty-eight patients harboring a total of 71 cerebral aneurysms previously treated with GDCs were included in the prospective study. MR angiography (at 1.5 T) was performed with a 3D TOF sequence before and after injection of gadolinium-based contrast material. Features evaluated were presence and size of a neck remnant, parent and adjacent vessel patency, and venous overlap. Digital subtraction angiography was the standard of reference. RESULTS: Comparison of the techniques showed a good agreement in the detection of residual flow. Six cases of small residual neck were not detected with either the 3D TOF or the contrast-enhanced 3D TOF sequence. In one case of giant aneurysm, the extent of recanalization was more evident after contrast material administration. The use of contrast material did not help to show the parent and adjacent arteries. Venous overlap on contrast-enhanced 3D TOF angiograms did not affect image interpretation. CONCLUSION. In this series, the use of intravenous contrast material did not improve the ability of 3D TOF MR angiography to depict the presence of residual or recurrent aneurysms previously treated with endovascular coiling. In one giant aneurysm, use of intravenous contrast material did result in improved visualization of a residual aneurysm.
引用
收藏
页码:1797 / 1803
页数:7
相关论文
共 50 条
  • [1] Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils
    Brunereau, L
    Cottier, JP
    Sonier, CB
    Medioni, B
    Bertrand, P
    Rouleau, P
    Sirinelli, D
    Herbreteau, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 216 - 223
  • [2] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    Westerlaan, HE
    van der Vliet, AM
    Hew, JM
    Meiners, LC
    Metzemaekers, JDM
    Mooij, JJA
    Oudkerk, M
    [J]. NEURORADIOLOGY, 2005, 47 (08) : 622 - 629
  • [3] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    H. E. Westerlaan
    A. M. van der Vliet
    J. M. Hew
    L. C. Meiners
    J. D. M. Metzemaekers
    J. J. A. Mooij
    M. Oudkerk
    [J]. Neuroradiology, 2005, 47 : 622 - 629
  • [4] Intracranial aneurysms treated with Guglielmi detachable coils - Imaging follow-up with contrast-enhanced MR Angiography
    Gauvrit, JY
    Leclerc, X
    Caron, S
    Taschner, CA
    Lejeune, JP
    Pruvo, JP
    [J]. STROKE, 2006, 37 (04) : 1033 - 1037
  • [5] Ultrashort T-E time-of-flight MR angiography improves the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDC)
    Gonner, F
    Heid, O
    Nicoli, G
    Remonda, L
    Schroth, G
    Seiler, RW
    [J]. 11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 957 - 962
  • [6] Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography
    Boulin, A
    Pierot, L
    [J]. RADIOLOGY, 2001, 219 (01) : 108 - 113
  • [7] Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils
    Anzalone, N
    Righi, C
    Simionato, F
    Scomazzoni, F
    Pagani, G
    Calori, G
    Santino, P
    Scotti, G
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (04) : 746 - 752
  • [8] Follow-up angiography of intracranial aneurysms treated with endovascular placement of Guglielmi detachable coils
    Thornton, J
    Debrun, GM
    Aletich, VA
    Bashir, Q
    Charbel, FT
    Ausman, J
    [J]. NEUROSURGERY, 2002, 50 (02) : 239 - 249
  • [9] Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography
    Cottier, JP
    Bleuzen-Couthon, A
    Gallas, S
    Vinikoff-Sonier, CB
    Bertrand, P
    Domengie, F
    Barantin, L
    Herbreteau, D
    [J]. NEURORADIOLOGY, 2003, 45 (11) : 818 - 824
  • [10] Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography
    J. P. Cottier
    A. Bleuzen-Couthon
    S. Gallas
    C. B. Vinikoff-Sonier
    P. Bertrand
    F. Domengie
    L. Barantin
    D. Herbreteau
    [J]. Neuroradiology, 2003, 45 : 818 - 824