A broad-standard technique for correcting for band broadening in size-exclusion chromatography

被引:3
|
作者
Zhang, Peng [1 ]
Mazoyer, Paul [2 ]
Gilbert, Robert G. [2 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Sch Pharm, Wuhan 430030, Hubei, Peoples R China
[2] Univ Queensland, Ctr Nutr & Food Sci, Queensland Alliance Agr & Food Innovat, Brisbane, Qld 4072, Australia
关键词
Size exclusion chromatography (SEC); GPC; Band broadening; MOLECULAR-WEIGHT DISTRIBUTIONS; FREE-RADICAL POLYMERIZATION; LIGHT-SCATTERING; SIMULTANEOUS CALIBRATION; ACCURATE DETERMINATION; MAXIMUM-ENTROPY; POLYMERS; SEPARATION; QUANTIFICATION; COEFFICIENTS;
D O I
10.1016/j.chroma.2016.03.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Band broadening in size-exclusion chromatography (SEC) is always present to some extent. Broadening effects on averages such as the weight- and number average molecular weights ((M-w) over bar and (M-n) over bar respectively) are minimal with modern SEC systems. However, broadening distorts the shape of the true molecular weight distribution (MWD), which causes problems if one wants to compare the detailed form of the MWD to a model. An addition to current methods for overcoming this problem is presented. One starts with a sufficiently wide range of samples whose exact values of (M-n) over bar and (M-w) over bar have been measured by non SEC methods (e.g. by fluorimetry and light scattering, respectively, of the sample without size separation). A true (unbroadened) molecular weight distribution for a sample can be obtained by deconvolution (here using a maximum-entropy algorithm) by fitting SEC data for these samples to these exact (M-n) over bar and (M-w) over bar values to find the values of the parameters in a sufficiently flexible assumed broadening function. This was modelled using simulated band broadening and subsequent deconvolution, with the broadening parameters least-squares fitted to the "exact" sets of values of (M-n) over bar and (M-w) over bar. The results show that if these (M-n) over bar and (M-w) over bar values are for a series of broad (not narrow) standards covering a sufficient range of molecular weight, then after deconvolution, a good representation of the original molecular weight distribution used in the simulation is obtained. The method should prove useful for water-soluble polymers, for which it is often difficult to obtain narrow standards of a wide range of molecular weight, as required in a number of well-established methods for correcting for band broadening. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 50 条
  • [21] SIZE-EXCLUSION CHROMATOGRAPHY AND SIZE-EXCLUSION CHROMATOGRAPHY FOURIER TRANSFORM INFRARED SPECTROMETRY OF REACTING ORGANOFUNCTIONAL TRIALKOXYSILANES
    MILLER, JD
    ISHIDA, H
    ANALYTICAL CHEMISTRY, 1985, 57 (01) : 283 - 288
  • [22] OPTIMIZATION OF EFFICIENCY IN SIZE-EXCLUSION CHROMATOGRAPHY
    ENGELHARDT, H
    AHR, G
    JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC): : 385 - 397
  • [23] Poppe plots for size-exclusion chromatography
    Popovici, ST
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) : 87 - 91
  • [24] Sizing Up Size-Exclusion Chromatography
    Matheson, Alasdair
    Striegel, Andre
    LC GC EUROPE, 2019, 32 (08) : 420 - 423
  • [25] Accuracy Validation of Size-Exclusion Chromatography
    Barth, Howard G.
    LC GC NORTH AMERICA, 2018, 36 (02) : 142 - 145
  • [26] Size-Exclusion Chromatography as a Technique for the Investigation of Novel Extracellular Vesicles in Cancer
    Liu, Daniel S. K.
    Upton, Flora M.
    Rees, Eleanor
    Limb, Christopher
    Jiao, Long R.
    Krell, Jonathan
    Frampton, Adam E.
    CANCERS, 2020, 12 (11) : 1 - 19
  • [27] Rapid size-exclusion chromatography of proteoglycans
    Johnson, PY
    Blake, DA
    JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (01): : 27 - 33
  • [28] Size-exclusion chromatography of perfluorosulfonated ionomers
    Mourey, T. H.
    Slater, L. A.
    Galipo, R. C.
    Koestner, R. J.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (34) : 5801 - 5809
  • [29] Size-exclusion chromatography with a multipore column
    Nagata, M
    BUNSEKI KAGAKU, 1998, 47 (11) : 895 - 896
  • [30] SIZE-EXCLUSION CHROMATOGRAPHY OF PROTEINS AND PEPTIDES
    ANTLE, PE
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1985, 62 (04) : 660 - 660