Standing Surface Acoustic Wave (SSAW)-Based Fluorescence-Activated Cell Sorter

被引:103
|
作者
Ren, Liqiang
Yang, Shujie [2 ]
Zhang, Peiran [2 ]
Qu, Zhiguo [3 ]
Mao, Zhangming [4 ]
Huang, Po-Hsun [2 ]
Chen, Yuchao [1 ]
Wu, Mengxi [2 ]
Wang, Lin [4 ]
Li, Peng [5 ]
Huang, Tony Jun [2 ]
机构
[1] Penn State Univ, Dept Engn Sci & Mech, University Pk, PA 16802 USA
[2] Duke Univ, Dept Mech Engn & Mat Sci, Durham, NC 27708 USA
[3] Xi An Jiao Tong Univ, Minist Educ, Key Lab Thermofluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
[4] Ascent Bionano Technol Inc, Res Triangle Pk, NC 27709 USA
[5] West Virginia Univ, C Eugene Bennett Dept Chem, Morgantown, WV 26506 USA
基金
中国国家自然科学基金; 美国国家卫生研究院; 美国国家科学基金会;
关键词
acoustofluidics; fluorescence-activated cell sorters; sheathless focusing; standing surface acoustic waves; ON-CHIP; WHOLE-BLOOD; MANIPULATION; SEPARATION; PARTICLES; CYTOMETER; POLYMER; DEVICES;
D O I
10.1002/smll.201801996
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microfluidic fluorescence-activated cell sorters (mu FACS) have attracted considerable interest because of their ability to identify and separate cells in inexpensive and biosafe ways. Here a high-performance mu FACS is presented by integrating a standing surface acoustic wave (SSAW)-based, 3D cell-focusing unit, an in-plane fluorescent detection unit, and an SSAW-based cell-deflection unit on a single chip. Without using sheath flow or precise flow rate control, the SSAW-based cell-focusing technique can focus cells into a single file at a designated position. The tight focusing of cells enables an in-plane-integrated optical detection system to accurately distinguish individual cells of interest. In the acoustic-based cell-deflection unit, a focused interdigital transducer design is utilized to deflect cells from the focused stream within a minimized area, resulting in a high-throughput sorting ability. Each unit is experimentally characterized, respectively, and the integrated SSAW-based FACS is used to sort mammalian cells (HeLa) at different throughputs. A sorting purity of greater than 90% is achieved at a throughput of 2500 events s(-1). The SSAW-based FACS is efficient, fast, biosafe, biocompatible and has a small footprint, making it a competitive alternative to more expensive, bulkier traditional FACS.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] ANTIGEN-SPECIFIC IDENTIFICATION AND CLONING OF HYBRIDOMAS WITH A FLUORESCENCE-ACTIVATED CELL SORTER
    PARKS, DR
    BRYAN, VM
    OI, VT
    HERZENBERG, LA
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1979, 76 (04) : 1962 - 1966
  • [32] FLUORESCENCE-ACTIVATED CELL SORTER ANALYSIS OF BULK-ISOLATED PORCINE OLIGODENDROCYTES
    SMYRNIS, E
    KIM, SU
    KIM, MW
    OGER, J
    SYLVESTER, C
    PATY, DW
    JOURNAL OF NEUROIMMUNOLOGY, 1986, 13 (01) : 47 - 60
  • [33] Femtosecond laser fabricated Micro Fluorescence-Activated Cell Sorter for single cell recovery
    Bragheri, F.
    Paie, P.
    Nava, G.
    Yang, T.
    Minzioni, P.
    Vazquez, R. Martinez
    Bellini, N.
    Ramponi, R.
    Cristiani, I.
    Osellame, R.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XII, 2014, 8976
  • [34] Numerical simulation for the design of a cell separation micro fluidic device using standing surface acoustic wave (SSAW)
    Yaotani, Ryota
    Yano, Tetsuya
    Transactions of Japanese Society for Medical and Biological Engineering, 2017, 55 Annual (5AM):
  • [35] RHESUS-MONKEY LYMPHOCYTE-B SURFACE-IMMUNOGLOBULIN - ANALYSIS WITH A FLUORESCENCE-ACTIVATED CELL SORTER
    FINKELMAN, FD
    SCHER, I
    JOURNAL OF IMMUNOLOGY, 1979, 122 (05): : 1757 - 1762
  • [36] USE OF FLUORESCENCE-ACTIVATED CELL SORTER TO STUDY INSULIN-RECEPTORS AND ISOLATE CELL VARIANTS
    MARON, R
    KAHN, CR
    CLINICAL RESEARCH, 1985, 33 (02): : A437 - A437
  • [37] APPLICATIONS OF THE FLUORESCENCE-ACTIVATED CELL SORTER TO THE STUDY OF NORMAL HUMAN T-CELL SUBSETS
    SHEIBANI, K
    VALENZUELA, R
    TURINIC, R
    ANTUNEZ, AR
    LABORATORY INVESTIGATION, 1982, 46 (01) : A76 - A76
  • [38] DETECTION OF FETAL ERYTHROCYTES IN MATERNAL BLOOD POST PARTUM WITH THE FLUORESCENCE-ACTIVATED CELL SORTER
    MEDEARIS, AL
    HENSLEIGH, PA
    PARKS, DR
    HERZENBERG, LA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (03) : 290 - 295
  • [39] EVALUATION AND CALIBRATION OF A FLUORESCENCE-ACTIVATED CELL SORTER FOR THE INTERPRETATION OF THE GRANULOCYTE IMMUNOFLUORESCENCE TEST (GIFT)
    MINCHINTON, RM
    ROCKMAN, S
    MCGRATH, KM
    CLINICAL AND LABORATORY HAEMATOLOGY, 1989, 11 (04): : 349 - 359
  • [40] Single-Cell Isolation and Cloning of Tetrahymena thermophila Cells with a Fluorescence-Activated Cell Sorter
    Mori, Kotaro
    Kashiwagi, Akiko
    Yomo, Tetsuya
    JOURNAL OF EUKARYOTIC MICROBIOLOGY, 2011, 58 (01) : 37 - 42