EXPERIMENTALLY VALIDATED NUMERICAL ANALYSIS OF REINFORCED CONCRETE SLAB-COLUMN CONNECTIONS SUBJECTED TO PUNCHING SHEAR

被引:1
|
作者
Florut, S. C. [1 ]
Popescu, D. A. [1 ]
Stoian, V [1 ]
Dan, D. [1 ]
Nagy-Gyorgy, T. [1 ]
Todea, V [1 ]
机构
[1] Politehn Univ Timisoara, Fac Civil Engn, 2nd T Lalescu, Timisoara 300223, Romania
关键词
reinforced concrete; flat slabs; punching shear; strengthening; numerical modelling; FLAT SLABS; STRENGTH;
D O I
10.2478/jaes-2020-0019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents the results of experimental investigations and numerical analyses performed on reinforced concrete flat slabs. Two tests were carried out on two flat slab specimens designed without specific shear reinforcement. The present paper deals only with the experimental behaviour and numerical modelling of such slabs, this representing the initial part of a larger study which aims to evaluate the shear capacity of such deficient slabs resulted from faulty design or execution and to identify viable and efficient strengthening solutions. ATENA finite element software package was used to numerically model the behaviour of the specimens. A very good agreement was achieved between the results of experimental investigations and numerical modelling with deviations of 0.2% in terms of maximum load carrying capacity and of 7% in terms of corresponding displacement. The specimens were able to carry loads of more than 950kN, larger than those evaluated using designated Eurocodes, displaying a safety factor of 2.72.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [21] PUNCHING SHEAR RESISTANCE OF CORNER SLAB-COLUMN CONNECTIONS
    HAMMILL, N
    GHALI, A
    ACI STRUCTURAL JOURNAL, 1994, 91 (06) : 697 - 707
  • [22] Reinforced concrete slab-column edge connections with shear studs
    El-Salakawy, EF
    Polak, MA
    Soliman, MH
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (02) : 338 - 348
  • [23] Punching of reinforced and post-tensioned concrete slab-column connections.
    Kang, Thomas H. -K.
    Wallace, John W.
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 366 - 367
  • [24] A design model for punching shear of FRP-reinforced slab-column connections
    Theodorakopoulos, D. D.
    Swamy, R. N.
    CEMENT & CONCRETE COMPOSITES, 2008, 30 (06): : 544 - 555
  • [25] Punching shear capacity of recycled-aggregate concrete slab-column connections
    Sahoo, Saumyaranjan
    Singh, Bhupinder
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [26] Punching Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Interior Connections
    Hussein, Ahmed H.
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2018, 115 (04) : 1075 - 1088
  • [27] Punching Shear Performance of Reinforced Concrete Slab-Column Joints with Shearhead Reinforcement
    Jiang, Yi
    Li, Yan
    Zhou, Jing
    Yi, Weiwen
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (10) : 1893 - 1918
  • [28] Rehabilitation of reinforced concrete slab-column connections
    El-Salakawy, EF
    Polak, MA
    Soudki, KA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (04) : 602 - 611
  • [29] Experimental, numerical, and theoretical study of punching shear capacity of corroded reinforced concrete slab-column joints
    Gomaa, Ahmed M.
    Lotfy, Ehab M.
    Khafaga, Sherif A.
    Hosny, Sally
    Ahmed, Manar A.
    ENGINEERING STRUCTURES, 2023, 289
  • [30] CFRP strengthening for punching shear of interior slab-column connections
    Sharaf, Mohamed H.
    Soudki, Khaled A.
    Van Dusen, Michael
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (05) : 410 - 418