A Simple flow-injection spectrofluorimetric method for the determination of mercury

被引:7
|
作者
Andac, Muberra [1 ]
Asan, Adem [1 ]
Tinkilic, Nihat [1 ]
Isildak, Ibrahim [1 ]
机构
[1] Ondokuz Mayis Univ, Dept Chem, Fac Sci, TR-55139 Kurupelit, Turkey
关键词
flow-injection analysis; mercury (II); fluorimetric determination; murexide;
D O I
10.1007/s10895-007-0182-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive flow-injection spectrofluorimetric method is presented for the rapid and simple determination of Hg (11) in environmental and pharmaceutical samples. Murexide (ammonium purpurate) was used as the fluorescence reagent in the carrier stream. An emission peak of murexide, which is decreased linearly by addition of Hg (11), occurs at 435 nm in aqueous solution with excitation at 335 nm. A linear calibration was obtained for 5-200 ng ml(-1) Hg (11) with the relative standard deviation 2.5% (n=5) for a 20 mu l injection volume Hg (II). The limit of the detection was 1 ng ml(-1) and the sampling rate was 80 h(-1). No significant interference was found by the ions commonly found in the most environmental samples. The proposed method was successfully applied for the determination of trace mercury in real samples and the validation of the proposed methodology is provided.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 50 条
  • [31] Spectrofluorimetric determination of formaldehyde by a flow-injection method based on its catalytic effect on the acridine yellow–bromate reaction
    T. Pérez-Ruíz
    C. Martínez-Lozano
    V. Tomás
    J. Fenoll
    Analytical and Bioanalytical Chemistry, 2003, 375 : 661 - 665
  • [32] SPECTROFLUORIMETRIC OPTOSENSING OF ALUMINUM IN A FLOW-INJECTION SYSTEM - DETERMINATION OF ALUMINUM IN DIALYSIS FLUIDS AND CONCENTRATES
    GARCIA, MRP
    GARCIA, MED
    SANZMEDEL, A
    ANALYST, 1990, 115 (05) : 575 - 579
  • [33] FLOW-INJECTION PROCEDURES FOR DETERMINATION OF IODIDE AND IODATE IODIDE WITH SPECTROFLUORIMETRIC AND SPECTROPHOTOMETRIC DETECTION, RESPECTIVELY
    YAQOOB, M
    MASOOM, M
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1991, 248 (01) : 219 - 224
  • [34] A simple flow-injection chemiluminescence method for the determination of trace pentavalent vanadium in water samples
    Zhang, Gai
    Meng, Zuchao
    Ma, Hairui
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (03) : 366 - 372
  • [35] A SIMPLE STOPPED-FLOW METHOD WITH CONTINUOUS PUMPING FOR THE SPECTROPHOTOMETRIC FLOW-INJECTION DETERMINATION OF BORON IN PLANTS
    ARRUDA, MAZ
    ZAGATTO, EAG
    ANALYTICA CHIMICA ACTA, 1987, 199 : 137 - 145
  • [36] Flow-injection atomic absorption spectrometry system for mercury determination in water
    Danet, AF
    Georgescu, E
    Cheregi, M
    Hiliuta, D
    LABORATORY ROBOTICS AND AUTOMATION, 1998, 10 (06) : 355 - 359
  • [37] Spectrofluorimetric determination of formaldehyde by a flow-injection method based on its catalytic effect on the acridine yellow-bromate reaction
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (05) : 661 - 665
  • [38] Determination of ascorbic acid by flow-injection chemiluminescence method
    Yu, J.
    Zhang, C.
    Tan, Y.
    Ge, S.
    Dai, P.
    Zha, Y.
    LUMINESCENCE, 2008, 23 (02) : 107 - 107
  • [39] FLOW-INJECTION DETERMINATION OF HMF IN HONEY BY THE WINKLER METHOD
    SALINAS, F
    MANSILLA, AE
    NEVADO, JJB
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04): : 250 - 252
  • [40] Flow-injection chemiluminescence method for the determination of hydrocortisone and progesterone
    Li, HN
    Ci, YX
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1484 - 1487