A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging

被引:11
|
作者
Deng, Luzhen [1 ,2 ]
Wei, Biao [1 ]
He, Peng [1 ,3 ]
Zhang, Yi [4 ]
Feng, Peng [1 ,3 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Room 1311,Main Bldg,Shapingba St, Chongqing 400044, Peoples R China
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Chongqing Univ, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Minist Educ, Chongqing 400044, Peoples R China
[4] Sichuan Univ, Coll Comp Sci, Chengdu 610065, Sichuan, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Geant4; Monte Carlo simulation; multi-pinhole; X-ray fluorescence computed tomography; gold nanoparticles; bioimaging modality; NANOPARTICLE-LOADED OBJECTS; EMISSION;
D O I
10.2147/IJN.S179875
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: X-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. Purpose: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs. Methods: The MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08-1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared. Results: The image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons. Conclusion: The MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.
引用
收藏
页码:7207 / 7216
页数:10
相关论文
共 50 条
  • [21] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [22] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [23] X-Ray Fluorescence Emission Tomography (XFET) With Novel Imaging Geometries-A Monte Carlo Study
    Meng, Ling Jian
    Li, Nan
    La Riviere, Patrick J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3359 - 3369
  • [24] Geant4-based Model of a Mouse Injected with Gold Nanoparticles for X-Ray Tomography Simulation Studies
    Jayarathna, Sandun
    Mulled, Md Foiez
    Cho, Sang Hyun
    [J]. 2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 71 - +
  • [25] Geant4-based Model of a Mouse Injected with Gold Nanoparticles for X-Ray Tomography Simulation Studies
    Jayarathna, Sandun
    Ahmed, Md Foiez
    Cho, Sang Hyun
    [J]. 2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 95 - 95
  • [26] Feasibility of X-ray Fluorescence Computed Tomography (XFCT) Imaging of Human Lung Tumors loaded with Gold Nanoparticles: A Monte Carlo Study
    Ahmed, Md Foiez
    Jayarathna, Sandun
    Cho, Sang Hyun
    [J]. 2018 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (IEEE - NANOMED), 2018, : 250 - 254
  • [27] Gamma Camera Imaging with Rotating Multi-Pinhole Collimator. A Monte Carlo Feasibility Study
    Ilisie, Victor
    Moliner, Laura
    Morera, Constantino
    Nuyts, Johan
    Benlloch, Jose Maria
    [J]. SENSORS, 2021, 21 (10)
  • [28] Denoising Algorithm of Multi-Pinhole Collimated X-Ray Fluorescence CT Based on Noise Level Estimation
    Zhao Ruge
    Feng Peng
    Luo Yan
    Zhang Song
    He Peng
    Liu Yanan
    [J]. ACTA OPTICA SINICA, 2023, 43 (20)
  • [29] Numerical and Monte Carlo Simulation for Polychromatic L-Shell X-ray Fluorescence Computed Tomography Based on Pinhole Collimator with Sheet-Beam Geometry
    Yang, Shuang
    Jiang, Shanghai
    Shi, Shenghui
    Hu, Xinyu
    Zhao, Mingfu
    [J]. PHOTONICS, 2022, 9 (12)
  • [30] Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry
    Amaro, Pedro
    Santos, Jose Paulo
    Samouco, Ana
    Adao, Ricardo
    Martins, Luis Souto
    Weber, Sebastian
    Tashenov, Stanislav
    Carvalho, Maria Luisa
    Pessanha, Sofia
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 60 - 66