A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging

被引:11
|
作者
Deng, Luzhen [1 ,2 ]
Wei, Biao [1 ]
He, Peng [1 ,3 ]
Zhang, Yi [4 ]
Feng, Peng [1 ,3 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Room 1311,Main Bldg,Shapingba St, Chongqing 400044, Peoples R China
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Chongqing Univ, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Minist Educ, Chongqing 400044, Peoples R China
[4] Sichuan Univ, Coll Comp Sci, Chengdu 610065, Sichuan, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Geant4; Monte Carlo simulation; multi-pinhole; X-ray fluorescence computed tomography; gold nanoparticles; bioimaging modality; NANOPARTICLE-LOADED OBJECTS; EMISSION;
D O I
10.2147/IJN.S179875
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: X-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. Purpose: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs. Methods: The MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08-1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared. Results: The image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons. Conclusion: The MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.
引用
收藏
页码:7207 / 7216
页数:10
相关论文
共 50 条
  • [1] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [2] Multi-Pinhole Based X-Ray Fluorescence Computed Tomography: A Comparison with Single Pinhole Case
    Sasaya, Tenta
    Sunaguchi, Naoki
    Seo, Seung-Jun
    Zeniya, Tsutomu
    Hyodo, Kazuyuki
    Kim, Jong-Ki
    Yuasa, Tetsuya
    [J]. IMAGE AND SIGNAL PROCESSING (ICISP 2018), 2018, 10884 : 205 - 212
  • [3] Multi-pinhole fluorescent x-ray computed tomography for molecular imaging
    Sasaya, Tenta
    Sunaguchi, Naoki
    Hyodo, Kazuyuki
    Zeniya, Tsutomu
    Yuasa, Tetsuya
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [4] Multi-pinhole fluorescent x-ray computed tomography for molecular imaging
    Tenta Sasaya
    Naoki Sunaguchi
    Kazuyuki Hyodo
    Tsutomu Zeniya
    Tetsuya Yuasa
    [J]. Scientific Reports, 7
  • [5] Imaging Experiment of Multi-Pinhole Based X-Ray Fluorescence Computed Tomography Using Rat Head Phantoms
    Sasaya, Tenta
    Oouchi, Tsuyoshi
    Yuasa, Tetsuya
    Seo, Seung-Jun
    Jeon, Jae-Geun
    Kim, Jong-Ki
    Sunaguchi, Naoki
    Hyodo, Kazuyuki
    Zeniya, Tsutomu
    [J]. 2019 27TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2019,
  • [6] Feasibility Simulation of 3D Benchtop Multi-Pinhole X-ray Fluorescence Computed Tomography with Two Novel Geometries
    Ye, Binqiang
    Deng, Luzhen
    Jiang, Shanghai
    Cao, Sijun
    Zhao, Ruge
    Feng, Peng
    [J]. PHOTONICS, 2023, 10 (04)
  • [7] GXPS: A Geant4-based Monte Carlo code for x-ray polycapillary simulation
    Chi, Zhijun
    [J]. JOURNAL OF APPLIED PHYSICS, 2020, 128 (12)
  • [8] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    [J]. MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [9] Monte Carlo Study for Pinhole X-ray Fluorescence Imaging of Gadolinium Nanoparticles
    Jung, Seongmoon
    Sung, Wonmo
    Ye, Sung-Joon
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [10] Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects
    Moktan, Hem
    Ahmed, Md Foiez
    Jayarathna, Sandun
    Deng, Luzhen
    Cho, Sang Hyun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17):