Analysis of hydroxyurea in human plasma by high performance liquid chromatography with electrochemical detection

被引:8
|
作者
Jong, YJ
Hsu, HO
Wu, HL
Kou, HS
Wu, SM [1 ]
机构
[1] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ, Dept Pediat, Kaohsiung 807, Taiwan
[3] Kaohsiung Med Univ, Dept Clin Lab, Kaohsiung 807, Taiwan
关键词
hydroxyurea; HPLC-ED; patients;
D O I
10.1016/S0003-2670(03)00702-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved HPLC-electrochemical detection (ED) method is described for the analysis of hydroxyurea (HU) in human plasma. After extraction process, HU was determined on a C 18 column (250 mm x 4 mm) by the mobile phase (25 mM sodium acetate-acetonitrile, 97.5:2.5; pH 6.5). The regression equations were linear (r > 0.9990). The precision and accuracy of intra- and inter-batches were all below 5% for relative standard deviation (R.S.D.) and relative error (R.E.). Based on 20 mul of plasma, the limit of detection was 0.3 muM for HU (S/N = 3, injection 10 mul). This method was applied for the HU drug monitoring of patients with myelofibrosis or polycythemia vera. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [21] Determination of melatonin in rat plasma by high performance liquid chromatography with electrochemical detection
    Chou, ST
    Perng, TF
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1997, 5 (02) : 131 - 137
  • [22] Determination of diclofenac in plasma by high-performance liquid chromatography with electrochemical detection
    Chmielewska, A
    Konieczna, L
    Plenis, A
    Bieniecki, M
    Lamparczyk, H
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (01) : 119 - 124
  • [23] DETERMINATION OF HYDRALAZINE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    WONG, JK
    JOYCE, TH
    MORROW, DH
    JOURNAL OF CHROMATOGRAPHY, 1987, 385 : 261 - 266
  • [24] Analysis of sofalcone in human plasma by high performance liquid chromatography
    Aidong, Wen
    Zhipeng, Wang
    Taijun, Hang
    Yanyan, Jia
    Tingting, Zhang
    Yin, Wu
    Xuan, Gao
    Zhifu, Yang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 348 - 352
  • [25] ANALYSIS OF SALBUTAMOL IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A MICRO-ELECTROCHEMICAL FLOW CELL
    SAGAR, KA
    HUA, C
    KELLY, MT
    SMYTH, MR
    ELECTROANALYSIS, 1992, 4 (04) : 481 - 486
  • [26] ANALYSIS OF TERBUTALINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A MICRO-ELECTROCHEMICAL FLOW CELL
    SAGAR, KA
    KELLY, MT
    SMYTH, MR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (01): : 109 - 116
  • [27] High-performance liquid chromatography with electrochemical detection applied to the analysis of 3,4-dihydroxymethamphetamine in human plasma and urine
    Segura, M
    Ortuno, J
    McLure, JA
    Pujadas, M
    Pizarro, N
    Farré, M
    Llebaria, A
    Joglar, J
    Segura, J
    de la Torre, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02): : 313 - 321
  • [28] ANALYSIS OF OLANZAPINE IN HUMAN PLASMA UTILIZING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    CATLOW, JT
    BARTON, RD
    CLEMENS, M
    GILLESPIE, TA
    GOODWIN, M
    SWANSON, SP
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (01): : 85 - 90
  • [29] Analysis of four alkaloids of Coptis chinensis in rat plasma by high performance liquid chromatography with electrochemical detection
    Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Wuhan University, Ministry of Education, Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China
    Anal. Chim. Acta, (99-104):
  • [30] Analysis of four alkaloids of Coptis chinensis in rat plasma by high performance liquid chromatography with electrochemical detection
    Liu, Lihong
    Chen, Zilin
    ANALYTICA CHIMICA ACTA, 2012, 737 : 99 - 104