Cervical sonography in pregnant women with a prior cone biopsy or loop electrosurgical excision procedure

被引:47
|
作者
Fischer, R. L. [1 ]
Sveinbjornsson, G. [1 ]
Hansen, C. [1 ]
机构
[1] Univ Med & Dent New Jersey, Cooper Univ Hosp, Robert Wood Johnson Med Sch Camden, Dept Obstet & Gynecol, Camden, NJ USA
关键词
cervical length; cervical sonography; cone biopsy; LEEP; PRETERM BIRTH; INTRAEPITHELIAL NEOPLASIA; TRANSFORMATION ZONE; CERCLAGE; LENGTH; PREVENTION; RISK; PREDICTION; MANAGEMENT; TRIAL;
D O I
10.1002/uog.7682
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To determine if pregnant women with a prior cone biopsy or loop electrosurgical excision procedure (LEEP) have a shorter midtrimester cervical length than do matched controls without a history of cervical surgery. Methods Eighty-five pregnant women with a singleton gestation and previous cone biopsy or LEEP and 85 controls matched by age (+/- 5 years), race, gestational age (+/- 2 weeks), and number of prior vaginal deliveries underwent a single transvaginal cervical sonographic scan at 15-22 weeks' gestation. No patient had a cerclage in either group. Results Mean cervical length was significantly shorter in the cone biopsy/LEEP group (3.3 vs. 3.9 cm, P < 0.001), with no significant difference in the proportion of cervical lengths less than 2.5 cm (5.9 vs. 2.4%). Gestational age at delivery was slightly but significantly lower in the cone biopsy/LEEP group (38.1 vs. 39.1 weeks, P = 0.005) than in the control group, with a higher proportion of women delivering late preterm and very preterm in the cone biopsy/LEEP group. However, no woman with a prior cone biopsy/LEEP experienced a midtrimester loss suggestive of cervical insufficiency, and no patient with a cervical length less than 2.5 cm delivered before 34 weeks' gestation. Conclusions Midtrimester cervical length in women with a previous cone biopsy or LEEP is significantly shorter than in those without prior cervical surgery. Based on the low frequency of a short cervix or midtrimester loss in women with prior excisional surgery, the routine use of midtrimester cervical sonography in such women is not supported. Copyright (C) 2010 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:613 / 617
页数:5
相关论文
共 50 条
  • [1] CERVICAL SONOGRAPHY IN PREGNANT WOMEN WITH PRIOR CONE BIOPSY OR LEEP
    Fischer, Richard
    Sveinbjornsson, Grace
    Hansen, Clare
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2008, 199 (06) : S133 - S133
  • [2] Midtrimester cervical elastography in pregnant women with a history of loop electrosurgical excision procedure (LEEP)
    Hyun-Hwa Cha
    Won Joon Seong
    Hyun Mi Kim
    Hyun-Joo Seol
    Ji-Hee Sung
    Hyun Soo Park
    Han-Sung Hwang
    Hayan Kwon
    Yun Ji Jung
    Ja-Young Kwon
    Soo-young Oh
    Scientific Reports, 12
  • [3] Midtrimester cervical elastography in pregnant women with a history of loop electrosurgical excision procedure (LEEP)
    Cha, Hyun-Hwa
    Seong, Won Joon
    Kim, Hyun Mi
    Seol, Hyun-Joo
    Sung, Ji-Hee
    Park, Hyun Soo
    Hwang, Han-Sung
    Kwon, Hayan
    Jung, Yun Ji
    Kwon, Ja-Young
    Oh, Soo-young
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Appropriate interval for repeat excision in women undergoing prior loop electrosurgical excision procedure for cervical neoplasia
    Kietpeerakool, Chumnan
    Srisomboon, Jatupol
    Tiyayon, Jitima
    Ruengkhachorn, Irene
    Cheewakriangkrai, Chalong
    Suprasert, Prapaporn
    Pantusart, Aree
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2007, 8 (03) : 379 - 382
  • [5] A randomized trial of the Fischer Cone Biopsy Excisor and loop electrosurgical excision procedure
    Fischer, NR
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (02): : 450 - 451
  • [6] Randomized trial of Fischer cone biopsy excisor and loop electrosurgical excision procedure
    Boardman, LA
    Steinhoff, MM
    Crowthers, L
    Weitzen, S
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 20S - 20S
  • [7] Compliance after loop electrosurgical excision procedure or cold knife cone biopsy
    Greenspan, David L.
    Faubion, Michelle
    Coonrod, Dean V.
    Hart, Kim Ward
    Mathieson, Kathleen
    OBSTETRICS AND GYNECOLOGY, 2007, 110 (03): : 675 - 680
  • [8] Specimen Fragmentation and Loop Electrosurgical Excision Procedure and Cold Knife Cone Biopsy Outcomes
    Grubman, Jessica
    Meinhardt, Summer S.
    Nambiar, Anjali
    Lea, Jayanthi S.
    JOURNAL OF LOWER GENITAL TRACT DISEASE, 2020, 24 (01) : 27 - 33
  • [9] Psychologic morbidities prior to loop electrosurgical excision procedure in the treatment of cervical intraepithelial neoplasia
    Le, T.
    Hopkins, L.
    Menard, C.
    Hicks-Boucher, W.
    Lefebvre, J.
    Fung, M. Fung Kee
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2006, 16 (03) : 1089 - 1093
  • [10] Diagnostic Accuracy of Colposcopically Directed Biopsy and Loop Electrosurgical Excision Procedure for Cervical Lesions
    Xiao, Feng-Yi
    Xie, Feng
    Sui, Long
    REPRODUCTIVE AND DEVELOPMENTAL MEDICINE, 2018, 2 (03) : 137 - 141