Randomized trial of Fischer cone biopsy excisor and loop electrosurgical excision procedure

被引:13
|
作者
Boardman, LA [1 ]
Steinhoff, MM [1 ]
Crowthers, L [1 ]
Weitzen, S [1 ]
机构
[1] Women & Infants Hosp Rhode Isl, Providence, RI 02908 USA
来源
OBSTETRICS AND GYNECOLOGY | 2004年 / 103卷 / 04期
关键词
D O I
10.1097/01.AOG.0000139517.26003.fc
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: To compare specimens obtained with the Fischer cone biopsy excisor or loop electrosurgical excision procedure (LEEP) with respect to number of specimens obtained, margin interpretability, adequacy of excision, and ease of use. METHODS: One hundred eligible patients aged 13 years and older were randomly assigned to treatment with the Fischer cone biopsy excisor or LEEP. Eligibility criteria included: (1) cervical intraepithelial neoplasia (CIN) 2 or 3, (2) persistent CIN 1, or (3) cytologic/histologic discrepancy. Following excision, providers ranked ease of use on a scale of 1 to 10. A pathologist blinded to procedure type analyzed specimens for margin interpretability and adequacy of excision. Before study initiation we calculated that a total of 100 patients would be required to demonstrate a significant difference in the interpretable margin rate of 80% for LEEP and 99% for cone biopsy excisor (power 80%, α = .05). RESULTS: After adjustment for ease of use, lesion size, and degree of neoplasia, the cone biopsy excisor was no more likely to result in a single specimen than LEEP (74% versus 63%, relative risk [RR] 0.93, 95% confidence interval [CI] 0.79-1.11), to result in a specimen with interpretable margins (65% versus 73%, RR 0.97, 95% CI 0.78-1.22), or to result in a fully excised cervical lesion (72% versus 62% for LEEPs, RR 1.08, 95% CI 0.77-1.52). Providers found their experiences with both Fischer cone biopsy excisor and LEEP cone biopsies to be similar, even after adjustment for year of training and previous experience (RR 0.95, 95% CI 0.72-1.24). CONCLUSION: The Fischer cone biopsy excisor and LEEP performed similarly with respect to the number of final specimens, margin interpretability, and ease of use. © 2004 by The American College of Obstetricians and Gynecologists.
引用
收藏
页码:20S / 20S
页数:1
相关论文
共 50 条
  • [1] A randomized trial of the Fischer Cone Biopsy Excisor and loop electrosurgical excision procedure
    Fischer, NR
    [J]. OBSTETRICS AND GYNECOLOGY, 2005, 105 (02): : 450 - 451
  • [2] Pregnancy outcome after electrosurgical cervical cone biopsy using Fischer cone biopsy excisor
    Anwar, Ayesha
    Igbenehi, Caleb
    Lindow, Stephen W.
    Noor, Naheed
    Musa, Siti
    Saha, Arabinda
    [J]. JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (03): : 477 - 481
  • [3] Compliance after loop electrosurgical excision procedure or cold knife cone biopsy
    Greenspan, David L.
    Faubion, Michelle
    Coonrod, Dean V.
    Hart, Kim Ward
    Mathieson, Kathleen
    [J]. OBSTETRICS AND GYNECOLOGY, 2007, 110 (03): : 675 - 680
  • [4] Cervical sonography in pregnant women with a prior cone biopsy or loop electrosurgical excision procedure
    Fischer, R. L.
    Sveinbjornsson, G.
    Hansen, C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (05) : 613 - 617
  • [5] Specimen Fragmentation and Loop Electrosurgical Excision Procedure and Cold Knife Cone Biopsy Outcomes
    Grubman, Jessica
    Meinhardt, Summer S.
    Nambiar, Anjali
    Lea, Jayanthi S.
    [J]. JOURNAL OF LOWER GENITAL TRACT DISEASE, 2020, 24 (01) : 27 - 33
  • [6] Loop electrosurgical excision procedure with or without intraoperative colposcopy: a randomized trial
    Hilal, Ziad
    Rezniczek, Guenther A.
    Alici, Ferizan
    Kumpernatz, Anne
    Dogan, Askin
    Alieva, Lale
    Tempfer, Clemens B.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 219 (04) : 377.e1 - 377.e7
  • [7] A pilot study comparing efficacy of a cervical intraepithelial neoplasia excisor with loop electrosurgical excision procedure
    Sanu, Olaleye
    Pal, Alak
    George, Samuel
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2010, 151 (01) : 91 - 95
  • [8] Negative for Dysplasia in Loop Electrosurgical Excision Procedure (LEEP) and Cold Knife Cone Biopsy: Review of 380 Cases
    Vo, N. T.
    Zhang, S.
    [J]. MODERN PATHOLOGY, 2012, 25 : 299A - 299A
  • [9] Negative for Dysplasia in Loop Electrosurgical Excision Procedure (LEEP) and Cold Knife Cone Biopsy: Review of 380 Cases
    Vo, N. T.
    Zhang, S.
    [J]. LABORATORY INVESTIGATION, 2012, 92 : 299A - 299A
  • [10] Syringe or mask? Loop electrosurgical excision procedure under local or general anesthesia: a randomized trial
    Rezniczek, Guenther A.
    Hecken, Julia M.
    Rehman, Sadia
    Dogan, Askin
    Tempfer, Clemens B.
    Hilal, Ziad
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 223 (06) : 888.e1 - 888.e9