Damping of taut-cable systems: Two dampers on a single stay

被引:45
|
作者
Caracoglia, Luca
Jones, Nicholas P.
机构
[1] Northeastern Univ, Dept Civil & Environm Engn, Boston, MA 02115 USA
[2] Johns Hopkins Univ, GWC Whiting Sch Engn, Baltimore, MD 21218 USA
关键词
bridges; cable-stayed; cables; vibration; damping;
D O I
10.1061/(ASCE)0733-9399(2007)133:10(1050)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The mitigation of in-plane stay oscillation in cable-stayed bridges is commonly addressed by placing an external mechanical damper, linear or nonlinear, on each stay or by introducing transverse cross-ties among cables. Although the problem of a cable with a single external damper has found significant attention in the past and different techniques have been proposed for the solution of the free-vibration problem, limitations are related to the fact that the location of the damper is usually very close to the cable end (on the bridge deck side) due to geometric constraints, leading to inherently low modal damping in the fundamental modes. In this paper the installation of more than one damper on an individual stay is considered to overcome such limitations and to increase the overall performance of the system. An existing procedure, based on the linearized taut-string theory, was modified to allow for the presence of multiple external discrete viscous dampers. The case of two devices with arbitrary location has been solved, identifying advantages and disadvantages of the proposed solution. In addition, extensions of the practical "universal curve" and the interpretation thereof are presented.
引用
收藏
页码:1050 / 1060
页数:11
相关论文
共 50 条
  • [31] Mitigating stay cable oscillation using semiactive damping
    Johnson, EA
    Baker, GA
    Spencer, BF
    Fujino, Y
    SMART STRUCTURES AND MATERIALS 2000: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS, 2000, 3988 : 207 - 216
  • [32] Stay cable vibration control by magneto-rheological (MR) dampers
    Wang, Xiuyong
    Chen, Zhengqing
    Ni, Yiqing
    He, Xuhui
    Huang, Fanglin
    Journal of Mechanical Strength, 2002, 24 (04)
  • [33] On Plan for Cable Tension Calculation under Considering the Influence of Dampers on Safety Inspection of Stay Cable
    Qu Zhihao
    Lin Li
    Li Husheng
    Zhang Lei
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 1909 - 1913
  • [34] Vibration Damping of a Taut Cable with the Hybrid Application of a Viscous Damper and a Tuned Mass Damper
    Yang, Xia
    Zhou, Haijun
    Cai, Chunsheng
    Huang, Xigui
    Du, YanLiang
    JOURNAL OF BRIDGE ENGINEERING, 2024, 29 (05)
  • [35] Characteristics of modal damping of steel and CFRP stay cables with oil dampers
    Shen, Yong-Gang
    Xie, Xu
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (05): : 94 - 101
  • [36] The effects of mechanical dampers on stay cables with high-damping rubber
    Nakamura, A
    Kasuga, A
    Arai, H
    CONSTRUCTION AND BUILDING MATERIALS, 1998, 12 (2-3) : 115 - 123
  • [37] Effectiveness of damping and inertance of two dampers on mitigation of multimode vibrations of stay cables by using the finite difference method
    Wang, Yuanyuan
    Li, Shouying
    Qie, Kai
    Zhou, Shuai
    Chen, Zhengqing
    JOURNAL OF VIBRATION AND CONTROL, 2023, 29 (13-14) : 3112 - 3125
  • [38] Damping ratio of stay cable attached with a viscous damper and a high damping rubber damper
    Nguyen, Duy Thao
    Vo, Duy Hung
    Chau, Si Quanh
    Nguyen, Cung Huy
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2024, 178 (01) : 15 - 26
  • [39] Experimental study on vibration mitigation of a stay cable using nonlinear hysteretic dampers
    Ko, JM
    Chen, Y
    Zheng, G
    Ni, YQ
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 1325 - 1332
  • [40] Dynamic properties of a stay cable incorporated with magneto-rheological fluid dampers
    Lou, WJ
    Ni, YQ
    Ko, JM
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 1341 - 1348