Absolute and relative dose distribution comparisons for convolution/superposition and Monte Carlo based treatment planning

被引:0
|
作者
Papanikolaou, N [1 ]
Stathakis, S [1 ]
Kappas, C [1 ]
机构
[1] Univ Kentucky, Sch Med, Dept Radiat Med, Lexington, KY 40536 USA
关键词
brachytherapy; prostate; implant;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Historically, the algorithms used for dose computation in radiotherapy treatment planning (RTP) have been based on measured data in water, The so-called model based algorithms (convolution, Monte Carlo) are now emerging as the dose engines of choice for 3D RTP as they can predict more accurately the dose distribution inside the patient based on the CT anatomy with minimum measured data input. In this work, we studied the effect of the dimensionality of a convolution/superposition dose algorithm on the absolute dose and relative dose distribution computed in several clinical cases and compared the outcome to Monte Carlo calculations. The convolution algorithm, calculates the dose at a point by summing together the total energy released per unit mass (TERMA) at all primary interaction sites as modified by the convolution kernel; the latter, reflects the percent of the energy released that is absorbed at the dose deposition site. patient tissue inhomogeneity can be (i) ignored, (ii) included in the TERMA calculation only and (iii) included in both the TERMA and the convolution kernel. The resulted isodose distribution and monitor units correspond then to homogeneous, 2.5D and 3D calculation type respectively. We used four clinical cases to study the dimensionality of the dose engine and compare to MC, We found remarkable difference between the three convolution calculation modes, but not much difference against the MC computations. The dosimetric and clinical implications In the choice of the algorithm will be presented as applied to the clinical sites that were Investigated.
引用
收藏
页码:1662 / 1663
页数:2
相关论文
共 50 条
  • [31] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses
    Catli, Serap
    Tanir, Gunes
    [J]. MEDICAL DOSIMETRY, 2013, 38 (03) : 332 - 336
  • [32] Radiotherapy treatment planning based on Monte Carlo techniques
    Juste, Belen
    Miro, Rafael
    Campayo, Juan M.
    Diez, Sergio
    Verdu, Gumersindo
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 252 - 257
  • [33] Monte Carlo-based inverse treatment planning
    Jeraj, R
    Keall, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1885 - 1896
  • [34] Dose painting by means of Monte Carlo treatment planning at the voxel level
    Jimenez-Ortega, E.
    Ureba, A.
    Vargas, A.
    Baeza, J. A.
    Wals-Zurita, A.
    Garcia-Gomez, J.
    Barbeiro, A. R.
    Leal, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 339 - 344
  • [35] Smoothing Monte Carlo calculated dose distributions for radiation treatment planning
    Kawrakow, I
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1352 - 1352
  • [36] Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning
    Li, JS
    Pawlicki, T
    Deng, J
    Jiang, SB
    Mok, E
    Ma, CM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10): : 2969 - 2985
  • [37] A vectorized Monte Carlo code for radiotherapy treatment planning dose calculation
    Weng, XJ
    Yan, YL
    Shu, HZ
    Wang, JW
    Jiang, SB
    Luo, LM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (07): : N111 - N120
  • [38] Commissioning fast Monte Carlo dose calculation for lung treatment planning
    Craig, J
    Wong, E
    Mulligan, M
    Gladwish, A
    Gaede, S
    Chen, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2113 - 2113
  • [39] Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning
    Chamberland, Eve
    Beaulieu, Luc
    Lachance, Bernard
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 60 - 79
  • [40] Comparison of Monte Carlo and convolution/superposition calculation methods: Quantification of the dose prediction errors arising from tissue heterogeneities
    Mihaylov, I
    Lerma, F
    Siebers, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1901 - 1902