Outcomes of the Surgical Treatment of Periprosthetic Fractures Around the Knee with Locking Plates: A Single Centre Experience

被引:2
|
作者
Atalay, I. B. [1 ]
Ozturk, R. [1 ]
Yapar, A. [1 ]
Karakoc, Y. [1 ]
Eksioglu, M. F. [1 ]
机构
[1] Dr Abdurrahman Yurtaslan Onkol Egitim & Arastirma, Dept Orthopaed & Traumatol, Ankara, Turkey
关键词
total knee arthroplasty; periprosthetic fracture; locking compression plates; FEMUR FRACTURES; FEMORAL FRACTURES; ARTHROPLASTY;
D O I
10.5704/MOJ.2111.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Surgical treatment options for periprosthetic fractures (PPF) include internal fixation with plate, intramedullary nailing and revision arthroplasty. We aimed at evaluating the surgical outcomes of patients who we had treated PPF with locking compression plates (LCP). Materials and methods: Twenty patients with PPF after primary total knee arthroplasty (TKA) between 2009 and 2016 were included in to the study. Knee Society Knee Scoring System (KSKSS) was used in the evaluation of radiologic and functional outcomes. There were periprosthetic supracondylar femoral fractures in 15 patients, and that of tibial fractures in 5 patients. For internal fixation, locking compression plate was preferred. Results: The mean age was 69 (range 61 to 78) years and the mean follow-up period was 72.25 (range 24 to 110) months. Union was achieved by 15.8 weeks in all the cases. Superficial infection and implant fracture were each seen in two patients. Revision operations were done to those patients with implant fracture. Mean KSKSS was 81.4 (75-87) and the mean functional score was 78.75 (75-85). Degenerative osteoarthritis patients were found to have higher age values than post-traumatic osteoarthritis patients (p = 0.001). When the union times were compared, it was found that the degenerative osteoarthritis patient group had a significantly shorter union than the post-traumatic osteoarthritis patient group (p = 0.036). Conclusion: Internal fixation with LCP is an effective treatment method in managing of PPF for patients with good bone stock. Rigid fixation should be done with the right surgical technique and an early movement must be initiated so that a good function can be achieved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] The characteristics and predictors of mortality in periprosthetic fractures around the knee
    Nasser, A. A. H. H.
    Sidhu, M.
    Prakash, R.
    Mahmood, A.
    BONE & JOINT JOURNAL, 2024, 106B (02): : 158 - 165
  • [22] Current Reconstruction Options in Periprosthetic Fractures Around the Knee
    Cacciola, Giorgio
    Mancino, Fabio
    De Meo, Federico
    Bruschetta, Antongiulio
    De Martino, Ivan
    Cavaliere, Pietro
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2021, 12
  • [23] Treatment of periprosthetic femoral fractures of the knee
    Ehlinger, Matthieu
    Adam, Philippe
    Abane, Lamine
    Rahme, Michel
    Moor, Beat Kaspar
    Arlettaz, Yvan
    Bonnomet, Francois
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1473 - 1478
  • [24] Surgical outcomes of non-periprosthetic distal femur fragility fractures treated with a locking plate
    Liu, Jiayong
    Hein, David
    Huffman, Christopher
    Rao, Brian M.
    Cooper, Jonathan
    Ebraheim, Nabil A.
    ANNALS OF JOINT, 2022, 7
  • [25] Adverse Events in the Treatment of Periprosthetic Fractures Around the Knee - a Clinical and Radiological Outcome Analysis
    Schreiner, Anna Janine
    Gonser, Christoph
    Ihle, Christoph
    Zauleck, Max Konstantin
    Klopfer, Tim
    Stuby, Fabian
    Stoeckle, Ulrich
    Ochs, Bjoern Gunnar
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2018, 156 (03): : 287 - 297
  • [26] The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis
    Kampshoff, Jorg
    Stoffel, Karl K.
    Yates, Piers J.
    Erhardt, Johannes B.
    Kuster, Markus S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (05) : 627 - 632
  • [27] Effectiveness of circular external fixator in periprosthetic fractures around the knee
    Koji Nozaka
    Naohisa Miyakoshi
    Michio Hongo
    Yuji Kasukawa
    Hidetomo Saito
    Hiroaki Kijima
    Hiroyuki Tsuchie
    Motoki Mita
    Yoichi Shimada
    BMC Musculoskeletal Disorders, 21
  • [28] The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis
    Jorg Kampshoff
    Karl K. Stoffel
    Piers J. Yates
    Johannes B. Erhardt
    Markus S. Kuster
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 627 - 632
  • [29] Periprosthetic fractures around the knee: current concepts and advances in management
    Michael R. Whitehouse
    Sanchit Mehendale
    Current Reviews in Musculoskeletal Medicine, 2014, 7 (2) : 136 - 144
  • [30] Periprosthetic fractures around the knee: current concepts and advances in management
    Whitehouse, Michael R.
    Mehendale, Sanchit
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2014, 7 (02) : 136 - 144