Determination of Se(IV) as a 5-nitropiazselenol complex by adsorptive stripping voltammetry at an in situ plated bismuth film electrode

被引:0
|
作者
Sharifian, Parisa [1 ]
Aliakbar, Alireza [1 ]
机构
[1] Guilan Univ, Fac Sci, Dept Chem, Rasht, Iran
关键词
PULSE POLAROGRAPHIC-DETERMINATION; SOLID-PHASE MICROEXTRACTION; CATALYTIC HYDROGEN WAVE; TRACE SELENIUM; MASS-SPECTROMETRY; HEAVY-METALS; SAMPLES; PHENYLENEDIAMINE; CHROMATOGRAPHY; SUPPLEMENTS;
D O I
10.1039/c5ay00432b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper a simple, selective, sensitive and reproducible stripping method based on adsorption of Se(IV) in the form of a 5-nitropiazoselenol complex at the surface of an in situ plated bismuth film electrode was introduced. All affecting parameters on adsorption, stripping and complex formation steps were evaluated and studied. Under optimum conditions the established calibration curve obeyed the linear regression equation in the range of 2 to 50 mg L-1 of Se(IV) concentrations. The estimated detection and quantification limits were 0.05 and 0.15 mg L-1 of Se(IV), respectively. In addition, the mean and RSD for determination of 5 mg L-1 of Se(IV) were calculated to be 4.91 and 2.8% (n=5). The accuracy of the method was certified by comparison of the results obtained from the proposed method and those obtained from ICP-OES as the reference method.
引用
收藏
页码:4321 / 4327
页数:7
相关论文
共 50 条
  • [41] Determination of Trace Chromium by Square-Wave Adsorptive Cathodic Stripping Voltammetry at an Improved Bismuth Film Electrode
    Zhang, Qing
    Zhong, Shang-wei
    Su, Jia-li
    Li, Xiang-jun
    Zou, Hong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H237 - H242
  • [42] Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
    Mardini Farias, Percio Augusto
    Castro, Arnaldo Aguiar
    ANALYTICAL CHEMISTRY INSIGHTS, 2014, 9 : 49 - 55
  • [43] Electrochemically Reduced Graphene Oxide Pencil-Graphite in situ Plated Bismuth-film Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry
    Pokpas, Keagan
    Zbeda, Salma
    Jahed, Nazeem
    Mohamed, Nuralli
    Baker, Priscilla G.
    Iwuoha, Emmanuel I.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (02): : 736 - 759
  • [44] Determination of selenium(IV) by stripping voltammetry at a mercury-film electrode
    Rubinskaya, TB
    Kovaleva, SV
    Kulagin, EM
    Gladyshev, VP
    JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (02) : 165 - 170
  • [45] Carbon paste electrode plated with lead film.: Voltammetric characteristics and application in adsorptive stripping voltammetry
    Bobrowski, Andrzej
    Krolicka, Agnieszka
    Lyczkowska, Ewa
    ELECTROANALYSIS, 2008, 20 (01) : 61 - 67
  • [46] Preparation of a Preplated Bismuth Film on Pt Electrode and its Application for Determination of Trace Aluminum(III) by Adsorptive Stripping Voltammetry
    Wang, Hongmei
    Yu, Zhanglong
    Wang, Zhiliang
    Hao, Haijun
    Chen, Yongmei
    Wan, Pingyu
    ELECTROANALYSIS, 2011, 23 (05) : 1095 - 1099
  • [47] Determination of Selenium(IV) by Stripping Voltammetry at a Mercury-Film Electrode
    T. B. Rubinskaya
    S. V. Kovaleva
    E. M. Kulagin
    V. P. Gladyshev
    Journal of Analytical Chemistry, 2003, 58 : 165 - 170
  • [48] Bismuth film electrode and chloranilic acid as a new alternative for simple, fast and sensitive Ge(iv) quantification by adsorptive stripping voltammetry
    Grabarczyk, Malgorzata
    Adamczyk, Marzena
    RSC ADVANCES, 2018, 8 (27): : 15215 - 15221
  • [49] Catalytic adsorptive stripping determination of trace chromium(VI) at the bismuth film electrode
    Lin, L
    Lawrence, NS
    Thongngamdee, S
    Wang, J
    Lin, YH
    TALANTA, 2005, 65 (01) : 144 - 148
  • [50] Square wave adsorptive stripping voltammetry of nickel(II) in flowing systems at a wall-jet mercury film electrode plated in situ
    Rocha, MMGS
    Neto, MMPM
    Torres, MO
    deVarennes, A
    ELECTROANALYSIS, 1997, 9 (02) : 145 - 149