Early Diagnosis of HIV-1 and HIV-2 Using Cobas HIV-1/HIV-2 Qualitative Test: A Novel Qualitative Nucleic Acid Amplification Test for Plasma, Serum, and Dried Blood Spot Specimens

被引:6
|
作者
Hans, Lucia [1 ,2 ]
von Allmen, Nicole [3 ]
Edelmann, Anke [3 ]
Hofmann, Jorg [3 ]
Nilsson, Alex Y. [4 ]
Simon, Christian O. [5 ]
Seiverth, Britta [6 ]
Gohl, Peter [7 ]
Carmona, Sergio [1 ,2 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Mol Med & Haematol, Johannesburg, South Africa
[2] Natl Hlth Lab Serv, Johannesburg, South Africa
[3] Lab Berlin Charite Vivantes Serv GmbH, Dept Virol, Berlin, Germany
[4] Roche Diagnost Int AG, Global Dev, Rotkreuz, Switzerland
[5] Roche Mol Syst Inc, Pleasanton, CA USA
[6] Roche Diagnost Int AG, Global Clin Operat, Rotkreuz, Switzerland
[7] Bioscientia Inst Med Diagnost, Ingelheim, Germany
关键词
HIV-1; HIV-2; HIV diagnostics; nucleic acid amplification tests; antigen infant diagnosis; acute HIV infection; dried blood spot; EARLY ANTIRETROVIRAL THERAPY; VIRUS; INFECTION; RNA; DNA;
D O I
10.1097/QAI.0000000000002713
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: Nucleic acid amplification tests (NATs) minimize the time from HIV infection to diagnosis, reducing transmission during acute HIV. NATs are especially useful for diagnosing HIV in children younger than 18 months and discriminating between HIV-1 and HIV-2. Methods: We evaluated the performance of the cobas HIV-1/HIV-2 qualitative (cobas HIV-1/2 Qual) test for use on cobas 6800/8800 Systems. The results of adult plasma and serum samples and pediatric dried blood spots were compared with those of the recomLine HIV-1 & HIV-2 Immunoglobulin G serological test and COBAS AmpliPrep/COBAS TaqMan HIV-1 qualitative test, v2.0. Genotype inclusivity and limits of detection were determined, and sensitivity on seroconversion panels was compared with that in the Bio-Rad Geenius HIV 1/2 Confirmatory Assay, Abbott ARCHITECT HIV Ag/Ab Combo serological test, and cobas TaqScreen MPX, v2.0. Results: Concordance of cobas HIV-1/2 Qual test with the comparator serological test and COBAS AmpliPrep/COBAS TaqMan test was >= 99.6% with all sample types. Reactivity with all HIV genotypes was 100%. LOD in plasma samples was 14.8, 12.6, and 27.9 copies/mL for HIV-1 group M, HIV-1 group O, and HIV-2, respectively, with similar results for serum samples. LOD in dried blood spots was 255 copies/mL for HIV-1 and 984 copies/mL for HIV-2. HIV infection was detected 18.9 days and 8.5 days earlier than the confirmatory and serological assays, respectively, and at a similar time to the NAT. Conclusions: The cobas HIV-1/2 Qual test enables early and accurate diagnoses of HIV-1 and HIV-2 in adults and children across sample types. The assay could help avert transmission during acute HIV, simplify HIV diagnostic algorithms, and promote the survival of HIV-infected children.
引用
收藏
页码:1187 / 1195
页数:9
相关论文
共 50 条
  • [31] An HIV-1/HIV-2 Chimeric Envelope Glycoprotein Generates Binding and Neutralising Antibodies against HIV-1 and HIV-2 Isolates
    Taveira, Nuno
    Figueiredo, Ines
    Calado, Rita
    Martin, Francisco
    Bartolo, Ines
    Marcelino, Jose M.
    Borrego, Pedro
    Cardoso, Fernando
    Barroso, Helena
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (10)
  • [32] HIV subtype detectability, HIV-1 seroconversion sensitivity and HIV-2 dilutional sensitivity by an automated HIV-1/HIV-2 chemiluminescent immunoassay.
    Edwin, C
    Barin, F
    Camacho, R
    Valle, H
    Kanki, P
    Fang, C
    Baker, L
    Tirrell, S
    CLINICAL CHEMISTRY, 1998, 44 : A4 - A4
  • [33] The challenge of discriminating between HIV-1, HIV-2 and HIV-1/2 dual infections
    Honge, B. L.
    Jespersen, S.
    Medina, C.
    Te, D. S.
    da Silva, Z. J.
    Christiansen, M.
    Kjerulff, B.
    Laursen, A. L.
    Wejse, C.
    Krarup, H.
    Erikstrup, C.
    HIV MEDICINE, 2018, 19 (06) : 403 - 410
  • [34] INCIDENCE OF HIV-1 AND HIV-2 ANTIBODIES IN HEMOPHILIACS
    SCHRAMM, W
    GURTLER, LG
    POHLMANN, H
    WEIGEL, I
    EBERLE, J
    DEINHARDT, F
    THROMBOSIS AND HAEMOSTASIS, 1987, 58 (01) : 369 - 369
  • [35] HIV-2 ANTIBODY REACTIVITY FOR HIV-1 ANTIGENS
    LILLO, F
    CAO, Y
    FERRO, A
    SABBATANI, S
    VARNIER, OE
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 1991, 7 (02) : 251 - 251
  • [36] A novel Real Time HIV-1 Qualitative assay for the detection of HIV-1 nucleic acids in dried blood spots and plasma
    Huang, Shihai
    Erickson, Brian
    Mak, Wai Bing
    Salituro, John
    Abravaya, Klara
    JOURNAL OF VIROLOGICAL METHODS, 2011, 178 (1-2) : 216 - 224
  • [37] DIFFERENCES IN HETEROSEXUAL TRANSMISSION OF HIV-1 AND HIV-2
    MOST, J
    SPOTL, L
    SARCLETTI, M
    VOGETSEDER, W
    DIERICH, MP
    ZANGERLE, R
    LANCET, 1994, 344 (8936): : 1572 - 1573
  • [38] TIME FOR HIV-1/HIV-2 COMBINATION TESTS
    CONSTANTINE, NT
    CALLAHAN, JD
    WATTS, DM
    JOURNAL OF VIROLOGICAL METHODS, 1989, 26 (02) : 219 - 221
  • [39] USE OF HIV-1 POL GENE PRECURSOR TO DETECT HIV-1 AND HIV-2
    REAGAN, KJ
    LILE, CC
    DEVASH, Y
    TURNER, J
    HU, YW
    KANG, CY
    LANCET, 1990, 335 (8683): : 236 - 236
  • [40] SEROLOGICAL DISCRIMINATION BETWEEN HIV-1 AND HIV-2
    SCHULZ, TF
    OBERHUBER, W
    SCHMIDT, B
    GSCHNAIT, F
    HENGSTER, P
    WACHTER, H
    DIERICH, MP
    LANCET, 1988, 2 (8603): : 162 - 163