Optimization of the rapping process of an intermittent electrostatic precipitator

被引:7
|
作者
Miloua, F. [1 ]
Tilmatine, A. [1 ]
Gouri, R. [1 ]
Kadous, N. [1 ]
Dascalescu, L. [1 ]
机构
[1] Univ Poitiers, IUT Angouleme, Poitiers, France
来源
关键词
D O I
10.1051/epjap:2007175
中图分类号
O59 [应用物理学];
学科分类号
摘要
Intermittent operation mode is specific to electrostatic precipitators (ESP) used in workshops where the polluting product is produced in a discontinuous way. The rapping system is necessary in order to ensure a continuous and effective operation of a dry electrostatic precipitator, but causes at the same time, a problem of re-entrainment of dust and thus the degradation of filtration efficiency. The objective of this paper is to propose a procedure based on the methodology of experimental designs (Tagushi's Methodology) aiming at optimizing the rapping process; it consists to determine optimal values of rapping, i.e. the moment, the position and the force of rapping. Several "one-factor-at-a-time" experimental designs followed by a Full Factorial design, made it possible to model the process and to analyze interactions between the factors. The experiments were carried out on a laboratory experimental device which simulates an industrial precipitator with intermittent operation.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 50 条
  • [31] Research on electrostatic shielding characteristics of electrostatic precipitator
    Chen, Bing
    Li, Shiqing
    Guo, Yongheng
    Li, Hongjiao
    Zhou, Wenning
    Liu, Baiqian
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2022, 72 (04) : 331 - 345
  • [32] Numerical modeling of electrostatic precipitator
    Long, Zhengwei
    Feng, Zhuangbo
    Yao, Qiang
    Huagong Xuebao/CIESC Journal, 2012, 63 (11): : 3393 - 3401
  • [33] LIQUID SURFACE ELECTROSTATIC PRECIPITATOR
    STRINDEHAG, OM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (01): : 95 - +
  • [34] NEW HOT ELECTROSTATIC PRECIPITATOR
    HENKE, WG
    COMBUSTION, 1970, 42 (04): : 50 - &
  • [35] ELECTROSTATIC PRECIPITATOR ROLLED INTO PLACE
    不详
    POWER ENGINEERING, 1973, 77 (05) : 98 - 98
  • [36] Conversion of an electrostatic precipitator into a baghouse
    McConnell, L
    Taylor, B
    Lijap, O
    Litke, H
    ZKG INTERNATIONAL, 2001, 54 (04): : 190 - +
  • [37] Electrostatic Precipitator Upgrade Opportunities
    Kumar, K. S.
    Knapik, J. A.
    POWER, 2013, 157 (04) : 36 - +
  • [38] UNIPOLAR COAGULATION IN AN ELECTROSTATIC PRECIPITATOR
    RICCIUS, O
    CHEMIE INGENIEUR TECHNIK, 1992, 64 (11) : 1018 - 1022
  • [39] EFFICIENCY STUDIES OF THE ELECTROSTATIC PRECIPITATOR
    LAUTERBACH, KE
    MERCER, TT
    HAYES, AD
    MORROW, PE
    AMA ARCHIVES OF INDUSTRIAL HYGIENE AND OCCUPATIONAL MEDICINE, 1954, 9 (01): : 69 - 75
  • [40] ELECTROSTATIC PRECIPITATOR MAINTENANCE SURVEY
    BUMP, RL
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1976, 26 (11): : 1061 - 1064