High sensitivity detection and monitoring of microcirculation using cutaneous and catheter probes for Doppler optical coherence tomography

被引:5
|
作者
Yang, VXD [1 ]
Gordon, ML [1 ]
Qi, B [1 ]
Yue, ES [1 ]
Tang, S [1 ]
Bisland, S [1 ]
Pekar, J [1 ]
Lo, S [1 ]
Marcon, N [1 ]
Wilson, BC [1 ]
Vitkin, IA [1 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
来源
OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III | 2003年 / 4965卷
关键词
blood flow; microcirculation; perfusion; optical coherence tomography; photodynamic therapy;
D O I
10.1117/12.503214
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Currently clinical Doppler ultrasound cannot detect microvascular blood flow and it is difficult to provide depth discrimination using laser Doppler flowmetry. Doppler optical coherence tomography (DOCT) is a novel technique for noninvasive subsurface imaging of microcirculation and tissue structure. Aims: To design handheld and catheter-based DOCT probes for clinical cutaneous and endoscopic imaging. To develop signal processing techniques for real-time detection and quantification of microvascular blood flow. Methods: A DOCT system, with interchangeable cutaneous and catheter probes, was developed. The axial spatial resolution was 10 mum, and the velocity resolution was 20 mum/s, using a 1300 mm broadband infrared light. The system achieved real-time imaging with frame rates up to 32 Hz at 512 x 256 pixels per frame. We used the system to detect microcirculation in human skin and rat esophagus, and to monitor microvascular responses to photodynamic therapy (PDT) in a rat tumor model. Results: We present experimental results from in vivo DOCT imaging of microcirculation in human skin arterio-venous malformations (AVM), normal rat esophagus, and a rat gliosarcoma PDT model. In the PDT model, we followed microvascular responses to PDT and observed differences in the microcirculation during and after therapy, which can have important implications for PDT dosimetry and treatment optimization. Conclusions: To our knowledge, this is the. first demonstration of endoscopic catheter-based DOLT detection of-microcirculation in vivo. In addition, AVM can be:: detected using handheld cutaneous DOCT probes under clinical settings. DOCT may serve as a real-time monitoring tool for PDT dosimetry, especially for vascular targeting photosensitizers.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 50 条
  • [31] IN VIVO IMAGING OF KIDNEY MICROVASCULATURE USING DOPPLER OPTICAL COHERENCE TOMOGRAPHY
    Wierwille, Jerry
    Wierwille, Jeremiah
    Andrews, Peter
    Onozato, Maristela
    Chen, Yu
    LASERS IN SURGERY AND MEDICINE, 2011, 43 : 913 - 913
  • [32] Measurement of ciliary beat frequency using Doppler optical coherence tomography
    Lemieux, Bryan T.
    Chen, Jason J.
    Jing, Joseph
    Chen, Zhongping
    Wong, Brian J. F.
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2015, 5 (11) : 1048 - 1054
  • [33] Digital phase stabilization to improve detection sensitivity for optical coherence tomography
    Tomlins, Peter H.
    Wang, Ruikang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) : 3365 - 3372
  • [34] Detection of bladder tumors using optical coherence tomography
    Pan, YT
    Xie, TQ
    Wang, ZG
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 56 - 61
  • [35] In vivo imaging of oral mucositis in an animal model using optical coherence tomography and optical Doppler tomography
    Wilder-Smith, Petra
    Hammer-Wilson, Marie J.
    Zhang, Jun
    Wang, Qiang
    Osann, Kathryn
    Chen, Zhongping
    Wigdor, Harvey
    Schwartz, Joel
    Epstein, Joel
    CLINICAL CANCER RESEARCH, 2007, 13 (08) : 2449 - 2454
  • [36] THE DIAGNOSIS OF CUTANEOUS LESIONS OF THE HEAD AND NECK USING OPTICAL COHERENCE TOMOGRAPHY
    Jerjes, Waseem
    Hamdoon, Zaid
    McKenzie, Gordon
    Hopper, Colin
    LASERS IN SURGERY AND MEDICINE, 2016, 48 (04) : 429 - 429
  • [37] Applications of Doppler Optical Coherence Tomography based on zero-crossing detection to flow monitoring inside a stenosis phantom
    Carrion, L.
    Xu, Z.
    Maciejko, R.
    PHOTONICS NORTH 2008, 2008, 7099
  • [38] Monitoring osteoarthritis in the rat model using optical coherence tomography
    Patel, NA
    Zoeller, J
    Stamper, DL
    Fujimoto, JG
    Brezinski, ME
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) : 155 - 159
  • [39] Remote Monitoring of Microparticle Biosensors Using Optical Coherence Tomography
    Shah, Shreyas
    Zheng, Mingde
    Eggleston, Michael
    2020 IEEE PHOTONICS CONFERENCE (IPC), 2020,
  • [40] Nanoscale structure detection and monitoring of tumour growth with optical coherence tomography
    Das, Nandan
    Sergey, Alexandrov
    Zhou, Yi
    Gilligan, Katie E.
    Dwyer, Roisin M.
    Leahy, Martin
    NANOSCALE ADVANCES, 2020, 2 (07): : 2853 - 2858