Low-energy EDARF spectrometry application in gold assaying

被引:18
|
作者
Marucco, A [1 ]
机构
[1] CNR, ITIA, I-20131 Milan, Italy
关键词
D O I
10.1016/S0168-583X(03)01608-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performances of a low-energy. dispersive XRF spectrometer in gold assaying are evaluated by a series of analysis on international standards and other certified gold alloys with. Results of standard-free analysis based on fundamental parameters method compared to results of multi-standard method, demonstrate a large gain of accuracy by drawing appropriate calibration curves with use of 1 to 16 matrix-specific standards. The accuracy of gold assaying has improved by a factor of 10, as compared to the conventional touchstone test. This rather economical technique satisfies then numerous precious alloys analyst needs, representing an excellent alternative to the traditional method for quick anti-fraud controls. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:486 / 490
页数:5
相关论文
共 50 条
  • [41] HEAVY ELEMENT ANALYSIS BY LOW-ENERGY ACCELERATOR MASS-SPECTROMETRY
    KILIUS, LR
    GARWAN, MA
    LITHERLAND, AE
    NADEAU, MJ
    RUCKLIDGE, JC
    ZHAO, XL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 745 - 749
  • [42] DIFFUSION OF GOLD INTO SILICON UNDER THE CONDITIONS OF LOW-ENERGY ION BOMBARDING
    BORISENKO, VE
    DIDIK, VA
    MALKOVICH, RS
    ZHURNAL TEKHNICHESKOI FIZIKI, 1982, 52 (01): : 167 - 169
  • [43] LOW-ENERGY STOPPING POWERS OF SOME HEAVY-IONS IN GOLD
    NDOCKONDONGUE, VB
    PAPE, AJ
    ARMBRUSTER, R
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1977, 33 (02): : 91 - 93
  • [44] DIFFUSION OF GOLD INTO SILICON DURING BOMBARDMENT BY LOW-ENERGY IONS.
    BORISENKO, V.E.
    DIDIK, V.A.
    MALKOVICH, R.SH.
    1982, V 27 (N 1): : 115 - 117
  • [45] LOW-ENERGY HIGH-ANGLE ELECTRON-IMPACT SPECTROMETRY
    KUPPERMA.A
    RICE, JK
    TRAJMAR, S
    JOURNAL OF PHYSICAL CHEMISTRY, 1968, 72 (11): : 3894 - &
  • [46] AN ION-SOURCE FOR LOW-ENERGY ION-SCATTERING SPECTROMETRY
    SU, CS
    GUH, YS
    VACUUM, 1990, 40 (05) : 467 - 469
  • [47] Characterization and Gold Assaying Methods in the Assessment of Low Grade Gold Ore from Malaysia
    Baharun, Norlia
    Ling, Ong Pek
    FRONTIERS IN MATERIALS AND MINERALS ENGINEERING, 2014, 858 : 243 - 247
  • [48] THERMAL METHODS AND MICROCALORIMETRY APPLICATION IN THE STUDIES OF LOW-ENERGY CEMENTS
    RAJCZYK, K
    NOCUNWCZELIK, W
    JOURNAL OF THERMAL ANALYSIS, 1992, 38 (04): : 771 - 775
  • [49] APPLICATION OF LOW-ENERGY PROTON ACTIVATION TO DETERMINATION OF LIGHT ELEMENTS
    DZEMARDYAN, YA
    MIKHAILOV, GI
    STARCHIK, LP
    INDUSTRIAL LABORATORY, 1971, 37 (05): : 708 - +
  • [50] APPLICATION OF LOW-ENERGY ION-SCATTERING TO STUDIES OF GROWTH
    BRONGERSMA, HH
    JACOBS, JP
    APPLIED SURFACE SCIENCE, 1994, 75 : 133 - 138