Optimized Density-Weighted Imaging for Dynamic Contrast-Enhanced 3D-MR Mammography

被引:0
|
作者
Gutberlet, Marcel [1 ,2 ]
Roth, Anne [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ]
机构
[1] Hannover Med Sch, Inst Radiol, D-30165 Hannover, Germany
[2] Univ Wurzburg, Inst Rontgendiagnost, Wurzburg, Germany
关键词
density weighting; spatial response function; signal-to-noise ratio; phase-constrained; 3D imaging; MR mammography; HUMAN HEART; SENSITIVITY; RECONSTRUCTION; ACQUISITION; RESOLUTION; GRAPPA; MRI; SENSE; WATER;
D O I
10.1002/jmri.22443
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To increase the spatial coverage and to reduce slice crosstalk combined with an optimal signal-to-noise ratio (SNR) in 3D dynamic contrast-enhanced (DCE) magnetic resonance (MR) mammography. Materials and Methods: Asymmetric sampling schemes and a new reconstruction strategy based on virtual coils are presented for density-weighted (DW) 3D imaging. Additionally, for MR mammography an alternating DW (ADW) sampling along the k(y) direction shifts the under-sampling artifacts out of the signal reception region. Virtual coils for effective DW (VIDED) imaging suppresses the abasing in undersampled DW imaging. VIDED and ADW were compared to the conventional Cartesian imaging in phantom and in vivo MR mammography studies. Results: The slice crosstalk was significantly reduced by VIDED and compared to Cartesian imaging the SNR increased by 16%. Additionally, VIDED and ADW provided a substantially increased field of view (FOV) in the slice direction and allowed the spatial resolution to be improved (up to 60% for ADW and 30% for VIDED) without lengthening the scan time. Conclusion: VIDED and ADW improve the image quality in 3D DCE MR mammography by enhancing the spatial resolution, reducing the slice crosstalk at nearly optimal SNR, and increasing the FOV in the slice direction. For VIDED no lengthening of the scan time or usage of multi-channel receiver coils is necessary. Key Words: density weighting; spatial response function; signal-to-noise ratio; phase-constrained; 3D imaging; MR mammography
引用
收藏
页码:328 / 339
页数:12
相关论文
共 50 条
  • [21] Detection of breast cancer with conventional mammography and contrast-enhanced MR imaging
    G. M. Kacl
    P.-F. Liu
    J. F. Debatin
    E. Garzoli
    R. F. Caduff
    G. P. Krestin
    European Radiology, 1998, 8 : 194 - 200
  • [22] 3D MR fingerprinting for dynamic contrast-enhanced imaging of whole mouse brain
    Zhu, Yuran
    Wang, Guanhua
    Gu, Yuning
    Zhao, Walter
    Lu, Jiahao
    Zhu, Junqing
    Macaskill, Christina J.
    Dupuis, Andrew
    Griswold, Mark A.
    Ma, Dan
    Flask, Chris A.
    Yu, Xin
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 67 - 79
  • [23] Reproducibility of Dynamic Contrast-enhanced MR Imaging Response
    Heye, Tobias J.
    Boll, Daniel T.
    RADIOLOGY, 2013, 269 (02) : 621 - 621
  • [24] Dynamic contrast-enhanced MR imaging of perianal fistulas
    Spencer, JA
    Ward, J
    Beckingham, IJ
    Adams, C
    Ambrose, NS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 735 - 741
  • [25] Contrast-enhanced dynamic MR imaging of cervical carcinoma
    Sato, Y
    Shimizu, T
    Kagei, K
    Suzuki, K
    RADIOLOGY, 1996, 201 : 570 - 570
  • [26] DUAL DYNAMIC CONTRAST-ENHANCED MR-IMAGING
    MIYATI, T
    KASAI, H
    SHUNDO, H
    BANNO, T
    IMAZAWA, M
    OHBA, S
    RADIOLOGY, 1995, 197 : 449 - 449
  • [27] Fundamentals of Quantitative Dynamic Contrast-Enhanced MR Imaging
    Paldino, Michael J.
    Barboriak, Daniel P.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (02) : 277 - +
  • [28] Dynamic contrast-enhanced 3D photoacoustic imaging
    Wong, Philip
    Kosik, Ivan
    Carson, Jeffrey J. L.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [29] Contrast-enhanced MR imaging
    Schima, W
    Mukerjee, A
    Saini, S
    CLINICAL RADIOLOGY, 1996, 51 (04) : 235 - 244
  • [30] Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: Basic experiments and clinical evaluation
    Naganawa, S
    Ito, T
    Iwayama, E
    Fukatsu, H
    Ishiguchi, T
    Ishigaki, T
    Ichinose, N
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05): : 813 - 820