Geometric optimization of toroidal ion trap based on electric field analysis and SIMION simulation

被引:3
|
作者
Yu, Quan [1 ]
Li, Man [1 ]
Lu, Xinqiong [1 ,3 ]
Wang, Xiaohao [1 ,2 ]
机构
[1] Tsinghua Univ, Div Adv Mfg, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Guangdong Prov Engn Res Ctr Urban Water Recycling, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Toroidal ion trap; Geometric optimization; Electric field analysis; SIMION modeling; Unidirectional ion excitation; MASS-SPECTROMETER; PERFORMANCE; MINIATURE; DESIGN; IMPACT;
D O I
10.1016/j.ijms.2018.09.003
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The toroidal-cylindrical ion trap (TCIT) is a small multi-function tandem ion trap analyzer with a simple structure and a compact design. The asymmetric structure of the out toroidal ion trap (T-trap) confers the in-trap region with a non-uniform electric field distribution, particularly when a plate ring electrode is used. To optimize the electric field distribution in the trap, the shapes of the toroidal electrodes were modified to compensate for the electric field. For this purpose, we developed a simple simulation-based method for evaluating the optimized asymmetric structure of the ion trap electrode. Specifically, static electric field distribution in the trap was acquired using COMSOL software and then simply analyzed, while the SIMION simulation platform was adopted to characterize both the ion motion and the performance of the T-trap with an modified structure. The results revealed that electrode optimization can not only improve the non-uniformity of the in-trap electric field distribution but also implement unidirectional emission of the ions upon resonance excitation, thereby significantly increasing the utilization efficiency of the ions in TCIT. In addition, a high correlation was found between the electric field gradient distribution in the trap and the ion emission characteristics, which can provide an simple but useful guiding significance for the performance and structural optimization of T-trap. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 50 条
  • [21] Optimization of Ion Trap Array Mass Analyzer by Computer Simulation
    Luo Chan
    Ding Chuan-Fan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (07) : 989 - 995
  • [22] Optimization of Resonant Excitation Electric Field in Discrete Electrode Printed Circuit Board Ion Trap Mass Analyzer
    Zhu Wen-Fei
    Wu Hui
    Ge Sai-Jin
    Zhang Ying-Jun
    Yao Ru-Jiao
    Jiang Gong-Yu
    Xiao Yu
    Li Xiao-Xu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (05) : 693 - 701
  • [23] The effect of a uniform radial electric field on the toroidal ion temperature gradient mode
    Peeters, AG
    Strintzi, D
    PHYSICS OF PLASMAS, 2004, 11 (08) : 3748 - 3751
  • [24] EXPERIMENTS ON ION HEATING IN A MAGNETIC MIRROR TRAP BY AN ALTERNATING ELECTRIC FIELD
    GOTT, YV
    YUSHMANO.EE
    SOVIET PHYSICS JETP-USSR, 1965, 21 (03): : 533 - &
  • [25] Measurement of the effective electric field radius on digital ion trap spectrometer
    Xu, Fuxing
    Wang, Weimin
    Jin, Liuyu
    Qian, Bingjun
    Ding, Chuan-Fan
    ANALYST, 2021, 146 (12) : 3810 - 3817
  • [26] Simulation and Optimization of Electric Field in Detector with Unsealed Field Cage
    Zhang J.
    Li W.
    Mi Z.
    Zhi Y.
    Sun P.
    Song J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2023, 57 (10): : 2000 - 2008
  • [27] Electric and magnetic field optimization procedure for Penning trap mass spectrometers
    Beck, D.
    Blaum, K.
    Bollen, G.
    Delahaye, P.
    George, S.
    Guenaut, C.
    Herfurth, F.
    Herlert, A.
    Lunney, D.
    Schweikhard, L.
    Yazidjian, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02): : 635 - 641
  • [28] Optimization of two-dimensional ion trap arrays for quantum simulation
    Siverns, James D.
    Weidt, Seb
    Lake, Kim
    Lekitsch, Bjoern
    Hughes, Marcus D.
    Hensinger, Winfried K.
    NEW JOURNAL OF PHYSICS, 2012, 14
  • [29] Optimization of Linear Ion Trap Mass Analyzer with Triangular Electrodes by Simulation
    Yao Ru-Jiao
    He Yang
    Xiao Yu
    Ding Zheng-Zhi
    Yuan Guang-Zhou
    Zhang Zai-Yue
    Qian Jie
    Zhang Shu-Guang
    Li Xiao-Xu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (11) : 1793 - 1797
  • [30] Investigation of the effect of an octopole electric field on a linear ion trap and an asymmetric semi-circular linear ion trap analyzer
    Xu, Fuxing
    Wang, Weimin
    Dai, Xinhua
    Fang, Xiang
    Ding, Chuan-Fan
    ANALYST, 2021, 146 (21) : 6455 - 6462