Propagation parameters for medium frequency signals in a transmission line at different positions within a mine entry

被引:0
|
作者
Li, Jingcheng [1 ]
Damiano, Nicholas W. [1 ]
Reyes, Miguel A. [1 ]
机构
[1] Natl Inst Occupat Safety & Hlth, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
关键词
propagation characteristics; transmission line;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A medium frequency (MF) communication system used in underground coal mines generally couples its electromagnetic signals to existing conductors in a mine entry (tunnel), and exchanges signals with transceivers near the conductors. The conductors act as a transmission line (TL). The propagation characteristics of the TL, which play a major role in determining the performance of an MF communication system, can be affected by a mine environment. This paper compares the measured propagation parameters of a TL in three different positions within a mine entry. This comparison shows that the differences between the electrical properties of local coal and rock close to the TL can influence the propagation characteristics of the TL when in a different position.
引用
收藏
页码:1251 / 1252
页数:2
相关论文
共 50 条
  • [41] Extraction of frequency dependent transmission line parameters using TDR/TDT measurements
    Swaminathan, M
    Pannala, S
    Roy, T
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 1726 - 1730
  • [42] Inclusion of frequency-dependent soil parameters in transmission-line modeling
    Siqueira de Lima, Antonio Carlos
    Portela, Carlos
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 492 - 499
  • [43] Distance protection for HVDC transmission line considering frequency-dependent parameters
    Zhang, J. (zhangjk@nw.sgcc.com.cn), 1600, Automation of Electric Power Systems Press (36):
  • [44] ERRORS IN MEASURING HIGH-FREQUENCY PARAMETERS AT INPUT TO A TRANSMISSION-LINE
    ZAKHARIT.MK
    FROLKIN, AA
    ELECTRICAL TECHNOLOGY, 1972, 3 : 129 - 133
  • [45] Generalized scattering parameters for two coupled transmission-line structures in an inhomogeneous medium
    Schwindt, R
    Nguyen, C
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1996, 12 (06) : 335 - 342
  • [46] Development of a transmission line model for calculating line parameters considering finite line length and tower propagation resistances at grounding points
    Nguyen, Thanh Binh
    Liebermann, Carlo
    Schegner, Peter
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2024, 141 (05): : 315 - 324
  • [47] The effects of non-uniformities and frequency dependence of line parameters on electromagnetic surge propagation
    Dávila, M
    Naredo, JL
    Moreno, P
    Gutiérrez, JA
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (03) : 151 - 157
  • [48] Propagation of fast PD signals within stator bars, performance and limitations of a high frequency monitoring system
    Lesaint, O
    Lebey, T
    Dinculescu, S
    Debruyne, H
    Petit, A
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1112 - 1115
  • [49] On-line Measuring Method of Power Frequency Impedance Parameters for Asymmetric Transmission Lines
    Yang, Ranchen
    Yao, Xuan
    Yang, Weichen
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS, ENVIRONMENT, BIOTECHNOLOGY AND COMPUTER (MMEBC), 2016, 88 : 710 - 713
  • [50] Estimation of High-Frequency Parameters of AC Machine From Transmission Line Model
    Ryu, Younggon
    Park, Bo-Ryang
    Han, Ki Jin
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (03)