Comparison between artificial neural network and partial least squares for on-line visible and near infrared spectroscopy measurement of soil organic carbon, pH and clay content

被引:117
|
作者
Kuang, Boyan [1 ]
Tekin, Yucel [2 ]
Mouazen, Abdul M. [1 ]
机构
[1] Cranfield Univ, Dept Environm Sci & Technol, Cranfield MK43 0AL, Beds, England
[2] Uludag Univ, Vocat Sch Tech Sci, Bursa, Turkey
来源
SOIL & TILLAGE RESEARCH | 2015年 / 146卷
关键词
Visible and near infrared; Soil; ANN; Spectroscopy; MOISTURE-CONTENT; PREDICTION; SENSOR; CALIBRATION; AGREEMENT; ACCURACY; SPIKING; MODELS; MATTER; SCALE;
D O I
10.1016/j.still.2014.11.002
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Soil organic carbon (OC), pH and clay content (CC) can be measured with on-line visible and near infrared spectroscopy (vis-NIRS), whose calibration method may considerably affect the measurement accuracy. The aim of this study was to compare artificial neural network (ANN) and partial least squares regression (PLSR) for the calibration of a visible and near infrared (vis-NIR) spectrophotometer for the on-line measurement of OC, pH and CC in two fields in a Danish farm. An on-line sensor platform equipped with a mobile, fiber type, vis-NIR spectrophotometer (AgroSpec from tec5 Technology for Spectroscopy, Germany), with a measurement range of 305-2200 nm was used to acquire soil spectra in diffuse reflectance mode. Both ANN and PLSR calibration models of OC, pH and CC were validated with independent validation sets. Comparison and full-point maps were developed using ArcGIS software (ESRI, USA). Results of the on-line independent validation showed that ANN outperformed PLSR in both fields. For example, residual prediction deviation (RPD) values for on-line independent validation in Field 1 were improved from 1.93 to 2.28, for OC, from 2.08 to 2.31 for pH and from 1.98 to 2.15 for CC, after ANN analyses as compared to PLSR, whereas root mean square error (RMSEP) values decreased from 1.48 to 1.25%, for OC, from 0.13 to 0.12 for pH and from 1.05 to 0.96% for CC. The comparison maps showed better spatial similarities between laboratory and ANN predicted maps (higher kappa values), as compared to PLSR predicted maps. In most cases, more detailed full-point maps were developed with ANN, although the size of spots with high concentration of PLSR maps matches the measured maps better. Therefore, it was recommended to adopt the ANN for on-line prediction of DC, pH and CC. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 50 条
  • [41] Predicting Organic Matter Content, Total Nitrogen and pH Value of Lime Concretion Black Soil Based on Visible and Near Infrared Spectroscopy
    He Yubing Wang
    Xiangyu Huang
    Eurasian Soil Science, 2021, 54 : 1681 - 1688
  • [42] Partial Least Squares Improved Multivariate Adaptive Regression Splines for Visible and Near-Infrared-Based Soil Organic Matter Estimation Considering Spatial Heterogeneity
    Wang, Xiaomi
    Yang, Can
    Zhou, Mengjie
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 16
  • [43] Modeling of soluble solid content of PE-packaged blueberries based on near-infrared spectroscopy with back propagation neural network and partial least squares (BP-PLS) algorithm
    Chen, Ya
    Li, Yaoxiang
    Williams, Roger A.
    Zhang, Zheyu
    Peng, Rundong
    Liu, Xiaoli
    Xing, Tao
    JOURNAL OF FOOD SCIENCE, 2023, 88 (11) : 4602 - 4619
  • [44] Determination of Eucalyptus globulus wood extractives content by near infrared-based partial least squares regression models: comparison between extraction procedures
    Alves, Ana M. M.
    Simoes, Rita F. S.
    Santos, Claudia A.
    Potts, Brad M.
    Rodrigues, Jose
    Schwanninger, Manfred
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2012, 20 (02) : 275 - 285
  • [45] Classification of Browning on Intact Table Grape Bunches Using Near-Infrared Spectroscopy Coupled With Partial Least Squares-Discriminant Analysis and Artificial Neural Networks
    Daniels, Andries J.
    Poblete-Echeverria, Carlos
    Nieuwoudt, Helene H.
    Botha, Nicolene
    Opara, Umezuruike Linus
    FRONTIERS IN PLANT SCIENCE, 2021, 12
  • [46] Non-destructive measurement of internal browning in mangoes using visible and near-infrared spectroscopy supported by artificial neural network analysis
    Gabriels, Suzan H. E. J.
    Mishra, Puneet
    Mensink, Manon G. J.
    Spoelstra, Patrick
    Woltering, Ernst J.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2020, 166
  • [47] Prediction of soluble solids content of pineapple via non-invasive low cost visible and shortwave near infrared spectroscopy and artificial neural network
    Chia, Kim Seng
    Rahim, Herlina Abdul
    Rahim, Ruzairi Abdul
    BIOSYSTEMS ENGINEERING, 2012, 113 (02) : 158 - 165
  • [48] Estimating the Acquisition Price of Enshi Yulu Young Tea Shoots Using Near-Infrared Spectroscopy by the Back Propagation Artificial Neural Network Model in Conjunction with Backward Interval Partial Least Squares Algorithm
    Sh.-P. Wang
    Z.-M. Gong
    X.-Zh. Su
    J.-Zh. Liao
    Journal of Applied Spectroscopy, 2017, 84 : 704 - 709
  • [49] Estimating the Acquisition Price of Enshi Yulu Young Tea Shoots Using Near-Infrared Spectroscopy by the Back Propagation Artificial Neural Network Model in Conjunction with Backward Interval Partial Least Squares Algorithm
    Wang, Sh. -P.
    Gong, Z. -M.
    Su, X. -Zh.
    Liao, J. -Zh.
    JOURNAL OF APPLIED SPECTROSCOPY, 2017, 84 (04) : 704 - 709
  • [50] Comparison of partial least square, artificial neural network, and support vector regressions for real-time monitoring of CHO cell culture processes using in situ near-infrared spectroscopy
    Zavala-Ortiz, Daniel A.
    Denner, Aurelia
    Aguilar-Uscanga, Maria G.
    Marc, Annie
    Ebel, Bruno
    Guedon, Emmanuel
    BIOTECHNOLOGY AND BIOENGINEERING, 2022, 119 (02) : 535 - 549