Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study

被引:14
|
作者
Kojima, Takashi [1 ]
Kitazawa, Yoshihiro [2 ]
Nakamura, Tomoaki [1 ]
Takahashi, Masahide [3 ]
Kamiya, Kazutaka [3 ]
Ichikawa, Kazuo [4 ]
Igarashi, Akihito [5 ]
Shimizu, Kimiya [5 ]
机构
[1] Nagoya Eye Clin, Nagoya, Aichi, Japan
[2] Kobe Kanagawa Eye Clin, Tokyo, Japan
[3] Kitasato Univ, Sch Allied Hlth Sci, Sagamihara, Kanagawa, Japan
[4] Chukyo Eye Clin, Nagoya, Aichi, Japan
[5] Sanno Hosp, Dept Ophthalmol, Tokyo, Japan
关键词
IN-SITU KERATOMILEUSIS; NIGHT-VISION DISTURBANCES; FOLLOW-UP; SATISFACTION; MODERATE; QUALITY; SAFETY;
D O I
10.1155/2018/7623829
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the visual and refractive outcomes and night vision performance questionnaire results between V4c and V5 implantable Collamer lenses in a prospective, randomized, multicenter study. Settings. Four refractive surgery centers. Design. Prospective randomized multicenter single-masked comparative study. Methods. Twenty-three patients were enrolled in this study. A conventional V4c model (EVO Visian ICL) was implanted in one eye, and a V5 model (EVO+ Visian ICL), which has a larger optic diameter than the V4c model, was implanted in the contralateral eye. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were evaluated before and 6 months after surgery. At 6 months after surgery, a questionnaire on night vision disturbances was administered. The efficacy, safety, and predictability of the two implanted ICI, models were compared. Results. There were no significant differences in the postoperative UDVA and CDVA between the two ICL models. The mean efficacy indexes for the V4c and V5 lenses were 1.16 +/- 0.22 and 1.03 +/- 0.23, respectively. The mean safety indexes of the V4c and V5 lenses were 1.21 +/- 0.20 and 1.19 +/- 0.20, respectively. The night vision performance questionnaire revealed that 7 patients (37%) noticed a difference in visual performance between the eyes, and all of them reported that they could see better at night with the VS-implanted eye compared with the V4c-implanted eye. Conclusion. The V4c and VS ICL models achieved similar visual and refractive outcomes, whereas the V5 model showed a possible advantage in reducing night vision disturbances.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study
    Luo, Wuqiang
    Aruma, Aruma
    Li, Meiyan
    Wang, Jing
    Xie, Jing
    Xiao, Xin
    Shen, Yang
    Niu, Lingling
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [42] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Xun Chen
    Huamao Miao
    Rajeev Krishnan Naidu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 16
  • [43] Comprehensive assessment of corneal microstructural changes following V4c implantable collamer lens surgery using in vivo confocal microscopy
    Wei, Qiaoling
    Chang, Weiteng
    Jiang, Rui
    Zhou, Xingtao
    Yu, Zhiqiang
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [44] Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography
    Fernandez-Vigo, Jose Ignacio
    Macarro-Merino, Ana
    Fernandez-Vigo, Cristina
    Fernandez-Vigo, Jose Angel
    Martinez-De-La-Casa, Jose Maria
    Fernandez-Perez, Cristina
    Garcia-Feijoo, Julian
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 162 : 43 - 52
  • [45] One-year Observation of Safety of Implantable Collamer Lens V4c Implantation Without Using an Ophthalmic Viscosurgical Device
    Chen, Zhuoyi
    Niu, Lingling
    Zhao, Jing
    Yao, Peijun
    Wang, Xiaoying
    Zhou, Xingtao
    FRONTIERS IN MEDICINE, 2022, 9
  • [46] The comparison of white-to-white via triple person-times caliper measuring and machine-measuring in V4c implantable collamer lens implantation
    Dan, Ting-Ting
    Liu, Tai-Xiang
    Li, Zong-Ze
    Liang, Ceng-Peng
    Li, Fa-Yuan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [47] Visual Outcomes Early after Implantable Collamer Lens V4c Implantation in Different Preoperative Spectacle Correction: Full Correction vs. Under Correction
    Zhu, Jiru
    Zhou, Tianan
    Yang, Qianjie
    Tong, Jianping
    Shen, Ye
    CURRENT EYE RESEARCH, 2023, 48 (06) : 576 - 583
  • [48] Clinical Observation of Posterior-Chamber Phakic Implantable Collamer Lens V4c Implantation in Myopic Patients with Shallow Anterior Chamber Depth: A Retrospective, Consecutive Observational Study
    Yuan, Juan
    Wu, Shuang
    Hu, Zongli
    Chen, Chunlin
    Ye, Shiyang
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2024, 2024
  • [49] Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
    Liu, Fang
    Xia, Fei
    Niu, Lingling
    Zhao, Jing
    Wang, Xiaoying
    Zhou, Xingtao
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (11):
  • [50] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120