Rapid and sensitive detection of Macrobrachium rosenbergii nodavirus in giant freshwater prawns by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick

被引:39
|
作者
Puthawibool, Teeranart [1 ]
Senapin, Saengchan [1 ,2 ]
Flegel, Timothy W. [1 ]
Kiatpathomchai, Wansika [1 ,2 ]
机构
[1] Mahidol Univ, Fac Sci, Bangkok 10400, Thailand
[2] Natl Sci & Technol Dev Agcy, Natl Ctr Genet Engn & Biotechnol, Pathum Thani 12120, Thailand
关键词
Macrobrachium rosenbergii nodavirus; White tail disease; Macrobrachium rosenbergii; Giant freshwater prawn; Loop-mediated isothermal amplification; Lateral flow dipstick; LAMP; PCR; LFD; MrNV; EXTRA SMALL VIRUS; WHITE-TAIL DISEASE; TAURA-SYNDROME VIRUS; SPOT SYNDROME VIRUS; RT-PCR; DE-MAN; DOT-BLOT; MRNV; SHRIMP; XSV;
D O I
10.1016/j.mcp.2010.07.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Loop-mediated isothermal amplification (LAMP) allows rapid amplification of nucleic acids under isothermal conditions. It can be combined with a chromatographic lateral flow dipstick (LFD) for much more efficient, field-friendly detection of MrNV. In this work, RT-LAMP was performed at 65 degrees C for 40 min, followed by 5 min for hybridization with an FITC-labeled DNA probe and 5 min for LFD resulted in visualization of DNA amplicons trapped at the LFD test line. Thus, total assay time, including 10 min for rapid RNA extraction was approximately 60 min. In addition to advantages of short assay time, confirmation of amplicon identity by hybridization and elimination of electrophoresis with carcinogenic ethidium bromide, the RT-LAMP LFD was more sensitive than an existing RT-PCR method for detection of MrNV. The RT-LAMP LFD method gave negative test results with nucleic acid extracts from normal shrimp and from shrimp infected with other viruses including DNA viruses [PstDNV (IHHNV), PemoNPV (MBV), PmDNV (HPV), WSSV] and RNA viruses (TSV, IMNV, YHV/GAV). (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:244 / 249
页数:6
相关论文
共 50 条
  • [41] Rapid and sensitive detection of Vibrio harveyi by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to vhhP2 gene
    Thongkao, Kanittada
    Longyant, Siwaporn
    Silprasit, Kun
    Sithigorngul, Paisarn
    Chaivisuthangkura, Parin
    AQUACULTURE RESEARCH, 2015, 46 (05) : 1122 - 1131
  • [42] Rapid Screening Detection of Genetically Modified Crops by Loop-Mediated Isothermal Amplification with a Lateral Flow Dipstick
    Takabatake, Reona
    Kagiya, Yukari
    Minegish, Yasutaka
    Futo, Satoshi
    Soga, Keisuke
    Nakamura, Kosuke
    Kondo, Kazunari
    Mano, Junichi
    Kitta, Kazumi
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (29) : 7839 - 7845
  • [43] Reverse transcription loop-mediated isothermal amplification for sensitive and rapid detection of Korean sacbrood virus
    Yoo, Mi-Sun
    Noh, Jin-Hyeong
    Yoon, Byoung-Su
    Reddy, Kondreddy Eswar
    Kweon, Chang-Hee
    Jung, Suk-Chan
    Kang, Seung-Won
    JOURNAL OF VIROLOGICAL METHODS, 2012, 186 (1-2) : 147 - 151
  • [44] Detection of Roundup Ready soybean by loop-mediated isothermal amplification combined with a lateral-flow dipstick
    Wang, Xiumin
    Teng, Da
    Guan, Qingfeng
    Tian, Fang
    Wang, Jianhua
    FOOD CONTROL, 2013, 29 (01) : 213 - 220
  • [45] Rapid and sensitive detection of cucumber mosaic virus by reverse transcription loop-mediated isothermal amplification
    Fan, Xiaorui
    Du, Yanan
    Cai, Youming
    Zhang, Yongchun
    Zhao, Xiao
    Liang, Jieling
    Yang, Dan
    Zhang, Qi
    Zhang, Xiaoxia
    Zhang, Wanjing
    Xu, Yan
    Zhao, Kai
    ACTA BIOCHIMICA ET BIOPHYSICA SINICA, 2019, 51 (02) : 223 - 226
  • [46] Rapid and sensitive detection of Taura syndrome virus by reverse transcription loop-mediated isothermal amplification
    Kiatpathomchai, Wansika
    Jareonram, Wansadaj
    Jitrapakdee, Sarawut
    Flegel, T. W.
    JOURNAL OF VIROLOGICAL METHODS, 2007, 146 (1-2) : 125 - 128
  • [47] Rapid and sensitive detection of Lily symptomless virus by reverse transcription loop-mediated isothermal amplification
    He, Xiangfeng
    Xue, Fei
    Xu, Shufa
    Wang, Wenhe
    JOURNAL OF VIROLOGICAL METHODS, 2016, 238 : 38 - 41
  • [48] Repaid and Accurate Detection of Khuskia oryzae by Loop-mediated isothermal Amplification Combined with a Lateral Flow Dipstick
    Xiong Yun
    Yang Hao
    Zhu Peng
    Huang Hailong
    He Qianqian
    Zhou Jian
    IAEDS15: INTERNATIONAL CONFERENCE IN APPLIED ENGINEERING AND MANAGEMENT, 2015, 46 : 877 - 882
  • [49] Rapid detection of Bombyx mori nucleopolyhedrovirus (BmNPV) by loop-mediated isothermal amplification assay combined with a lateral flow dipstick method
    Zhou, Yang
    Wu, Jiege
    Lin, Feng
    Chen, Naifu
    Yuan, Shaofei
    Ding, Lina
    Gao, Li
    Hang, Bangxing
    MOLECULAR AND CELLULAR PROBES, 2015, 29 (06) : 389 - 395
  • [50] Reverse transcription loop-mediated isothermal amplification for rapid and quantitative assay of covert mortality nodavirus in shrimp
    Zhang, Qingli
    Liu, Shuang
    Yang, Haolin
    Zhu, Luoluo
    Wan, Xiaoyuan
    Li, Xiaoping
    Huang, Jie
    JOURNAL OF INVERTEBRATE PATHOLOGY, 2017, 150 : 130 - 135