Detection of cervical lymph node metastases in nasopharyngeal carcinomas: Comparison between technetium-99m methoxyisobutylisonitrile single photon emission computed tomography and computed tomography

被引:0
|
作者
Sun, SS
Tsai, SC
Ho, YJ
Kao, CH
机构
[1] Taichung Vet Gen Hosp, Dept Nucl Med, Taichung 40705, Taiwan
[2] China Med Coll Hosp, Dept Nucl Med, Taichung, Taiwan
[3] Show Chwan Mem Hosp, Dept Nucl Med, Chunghua, Taiwan
[4] Jen Ai Hosp, Dept Radiol, Taichung, Taiwan
关键词
cervical lymph node metastases; nasopharyngeal carcinoma; techentium-99m methoxyisobutylisonitrile; single photon emission computed tomography; computed tomography;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study was to compare the effectiveness of technetium-99m methoxyisobutylisonitrile (Tc-99m MIBI) single photon emission computed tomography (SPECT) and computed tomography (CT) of head and neck in evaluating cervical lymph node (LN) metastasis in nasopharyngeal carcinomas (NPC). Fifty NPC patients with suspected cervical LN metastases underwent Tc-99m MIBI SPECT and CT of the head and neck to evaluate cervical LN metastases. Among the 50 patients cervical LN lesion were confirmed by biopsy histopathological results in 40 patients. For 22 LN lesions with discordant results between Tc-99m MIBI SPECT and CT Tc-99m MIBI SPECT could correctly detect 5 metastatic and 7 benign LN lesions, while could correctly detect 5 metastatic and 6 benign LN lesions. Tc-99m MIBI SPECT and CT could correctly detect all of the 18 metastatic LN lesions. Tc-99m MIBI SPECT showed a better specificity but a lower sensitivity for detecting cervical LN metastases in NPC when compared with CT. The combined use of Tc-99m MIBI SPECT and CT could increase the accuracy, compared with the single use of either Tc-99m MIBI SPECT or CT to detect cervical LN metastases in NPC.
引用
收藏
页码:1307 / 1310
页数:4
相关论文
共 50 条
  • [31] Technetium-99m methoxy-isobutyl-isonitrile chest single photon emission computed tomography to detect mediastinal lymph node meastasis in patients with non-small cell lung cancer: Comparison with computed tomography
    Shiau, YC
    Hsieh, JF
    Tsai, SC
    Ho, YJ
    Sun, SS
    Kao, CH
    ANTICANCER RESEARCH, 2000, 20 (5C) : 3751 - 3754
  • [32] Erratum to: Single-Photon-Emission Computed Tomography (SPECT) with Technetium-99m Sestamibi in the Diagnosis of Small Breast Cancer and Axillary Lymph Node Involvement
    Alessandro DeCesare
    Giuseppe DeVincentis
    Stefano Gervasi
    Giacomo Crescentini
    Enrico Fiori
    Marco Bonomi
    Alessandro Crocetti
    Antonio V. Sterpetti
    World Journal of Surgery, 2012, 36 : 693 - 693
  • [33] A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma
    Kostakoglu L.
    Uysal U.
    Özyar E.
    Demirkazik F.B.
    Hayran M.
    Atahan L.
    Bekdik C.F.
    European Journal of Nuclear Medicine, 1997, 24 (6) : 621 - 628
  • [34] A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma
    Kostakoglu, L
    Uysal, U
    Ozyar, E
    Demirkazik, FB
    Hayran, M
    Atahan, L
    Bekdik, CF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (06): : 621 - 628
  • [35] Comparison of lymphoscintigraphy and single photon emission computed tomography with computed tomography (SPECT/CT) for sentinel lymph node detection in endometrial cancer
    Togami, Shinichi
    Kawamura, Toshihiko
    Yanazume, Shintaro
    Kamio, Masaki
    Kobayashi, Hiroaki
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2020, 30 (05) : 626 - 630
  • [36] Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography: A case report
    Liu, Chang-Jiang
    Yang, Hua-Jun
    Peng, Yan-Chun
    Huang, De-Yu
    WORLD JOURNAL OF CLINICAL CASES, 2023, 11 (12)
  • [37] Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography: A case report
    Chang-Jiang Liu
    Hua-Jun Yang
    Yan-Chun Peng
    De-Yu Huang
    World Journal of Clinical Cases, 2023, (12) : 2825 - 2831
  • [38] Detecting Synchronous Parathyroid Adenoma and False-Positive Findings on Technetium-99m MIBI Single Photon-Emission Computed Tomography/Computed Tomography
    Lee, Ji Young
    Song, Hee-Sung
    Choi, Jae Hyuck
    Hyun, Chang Lim
    Lee, Sang Ah
    Choi, Joon-Hyouk
    Lee, Seokjae
    DIAGNOSTICS, 2019, 9 (02):
  • [39] Validation of single-photon emission computed tomography with computed tomography and lymphoscintigraphy for sentinel lymph node identification in cervical cancer
    Togami, Shinichi
    Tokudome, Akio
    Fukuda, Mika
    Mizuno, Mika
    Yanazume, Shintaro
    Kobayashi, Hiroaki
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2023, 163 (03) : 813 - 817
  • [40] Technetium-99m tetrofosmin myocardial perfusion single photon emission computed tomography in syndrome X - A preliminary report
    Hsu, HB
    Shiau, YC
    Kao, A
    Lin, CC
    Lee, CC
    JAPANESE HEART JOURNAL, 2003, 44 (02): : 153 - 162