High-flow humidified nasal preoxygenation in pregnant women: a prospective observational study

被引:51
|
作者
Tan, P. C. F. [1 ,5 ]
Millay, O. J. [1 ]
Leeton, L. [1 ]
Dennis, A. T. [1 ,2 ,3 ,4 ]
机构
[1] Royal Womens Hosp, Dept Anaesthesia, Parkville, Vic, Australia
[2] Univ Melbourne, Anaesthesia Perioperat & Pain Med Unit, Dept Obstet & Gynaecol, Parkville, Vic, Australia
[3] Univ Melbourne, Anaesthesia Perioperat & Pain Med Unit, Dept Pharmacol, Parkville, Vic, Australia
[4] Univ Melbourne, Anaesthesia Perioperat & Pain Med Unit, Dept Med & Radiol, Parkville, Vic, Australia
[5] Univ Melbourne, Dept Obstet & Gynaecol, Parkville, Vic, Australia
基金
英国医学研究理事会;
关键词
pregnancy; obstetrical anesthesia; airway management; oxygen; end-tidal; face mask; nasal cannula; VENTILATORY EXCHANGE THRIVE; FAILED TRACHEAL INTUBATION; RAPID-SEQUENCE INDUCTION; PRE-OXYGENATION; GENERAL-ANESTHESIA; DIFFICULT; APNEA;
D O I
10.1016/j.bja.2018.08.015
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Obstetric airway guidelines recommend preoxygenation in preparation for general anaesthesia to achieve end-tidal oxygen concentrations (etO(2)) of >= 90%, and mention the potential use of high-flow humidified nasal oxygen (HFNO). We investigated the new HFNO technique (Optiflow (TM)) in term pregnant women. Methods: Seventy-three term participants underwent a 3 min HFNO protocol (30 L min(-1) for 30 s, and then 50 L min(-1) for 150 s). The etO(2) was assessed for the first four breaths after simulated preoxygenation. The primary outcome was the proportion who achieved etO(2) >= 90% for the first expired breath. The secondary outcomes were the proportion who achieved etO(2) >= 80%; fetal heart rate before and after the test; the association of body mass index (BMI) to etO(2) achieved with preoxygenation; and comfort levels of, and preference for, nasal and face mask preoxygenation. Results: The proportion with first expired breath etO(2) >= 90% was 60% [95% confidence interval (CI): 54-66%] and etO(2) >= 80% was 84% (95% CI: 80-88%). There was no change in fetal heart rate from before to after the test (P = 0.34). There was a negative association of BMI to etO(2) achieved with preoxygenation (Pearson correlation: -0.26; P = 0.027). There was no difference in comfort scores between nasal cannula and face mask (P = 0.40). Forty-one (56%; 95% CI: 35-47%) women preferred the nasal cannula to the face mask. Conclusions: HFNO using this protocol is inadequate to preoxygenate term pregnant women. Despite encouraging results in the literature reporting results in non-pregnant women, further work is required before justifying its use in pregnant women.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [21] Nasal high-flow preoxygenation for endotracheal intubation in the critically ill patient? Con
    Hanouz, Jean-Luc
    Gerard, Jean Louis
    Fischer, Marc Olivier
    INTENSIVE CARE MEDICINE, 2019, 45 (04) : 526 - 528
  • [22] Nasal high-flow preoxygenation for endotracheal intubation in the critically ill patient? Pro
    Ricard, Jean-Damien
    Gregoretti, Cesare
    INTENSIVE CARE MEDICINE, 2019, 45 (04) : 529 - 531
  • [23] Nasal high-flow preoxygenation for endotracheal intubation in the critically ill patient? Maybe
    Chanques, Gerald
    Jaber, Samir
    INTENSIVE CARE MEDICINE, 2019, 45 (04) : 532 - 534
  • [24] High-flow oxygen therapy through nasal cannula: Prospective observational study in an intermediate care unit
    Demelo-Rodriguez, P.
    Olmedo Samperio, M.
    Gaitan Tocora, D. G.
    Cano Ballesteros, J. C.
    del Toro Cervera, J.
    Andueza Lillo, J. A.
    REVISTA PORTUGUESA DE PNEUMOLOGIA, 2016, 22 (05) : 292 - 293
  • [25] Humidified high-flow nasal cannula oxygen for bronchiolitis: should we go with the flow?
    Mace, Ariel O.
    Gibbons, James
    Schultz, Andre
    Knight, Geoff
    Martin, Andrew C.
    ARCHIVES OF DISEASE IN CHILDHOOD, 2018, 103 (03) : 303 - 303
  • [26] A randomized pilot study comparing heated humidified high-flow nasal cannulae with NIPPV for RDS
    Kugelman, Amir
    Riskin, Arieh
    Said, Waseem
    Shoris, Irit
    Mor, Frida
    Bader, David
    PEDIATRIC PULMONOLOGY, 2015, 50 (06) : 576 - 583
  • [27] Heated humidified high-flow nasal cannula: a new conservative approach for neonatal nasal stenosis
    Havazelet, Shany
    Stafler, Patrick
    Zarzur, Ihab
    Coreanu, Tara
    Hod, Roy
    Armoni-Domany, Keren
    Gilony, Dror
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (10) : 5261 - 5266
  • [28] Heated, Humidified High-Flow Nasal Cannula Versus Nasal CPAP for Respiratory Support in Neonates
    Yoder, Bradley A.
    Stoddard, Ronald A.
    Li, Ma
    King, Jerald
    Dirnberger, Daniel R.
    Abbasi, Soraya
    PEDIATRICS, 2013, 131 (05) : E1482 - E1490
  • [29] Heated, humidified, high-flow nasal oxygen usage in the adult Emergency Department
    Hughes, James
    Doolabh, Ammara
    AUSTRALASIAN EMERGENCY NURSING JOURNAL, 2016, 19 (04) : 173 - 178
  • [30] Evidence Support and Guidelines for Using Heated, Humidified, High-Flow Nasal Cannulae in Neonatology Oxford Nasal High-Flow Therapy Meeting, 2015
    Roehr, Charles C.
    Yoder, Bradley A.
    Davis, Peter G.
    Ives, Kevin
    CLINICS IN PERINATOLOGY, 2016, 43 (04) : 693 - +