3.5 cm Artificial Urinary Sphincter Cuff Erosion Occurs Predominantly in Irradiated Patients

被引:65
|
作者
Simhan, Jay [1 ]
Morey, Allen F. [1 ]
Singla, Nirmish [1 ]
Tausch, Timothy J. [1 ]
Scott, J. Francis [1 ]
Lemack, Gary E. [1 ]
Roehrborn, Claus G. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Urol, Dallas, TX 75390 USA
来源
JOURNAL OF UROLOGY | 2015年 / 193卷 / 02期
关键词
urinary bladder; urethra; urinary incontinence; stress; urinary sphincter; artificial; complications; POSTPROSTATECTOMY INCONTINENCE; REVISION SURGERY; IMPLANTATION; OUTCOMES; RISK; MEN; EXPLANTATION; PLACEMENT; RADIATION; FAILURES;
D O I
10.1016/j.juro.2014.07.115
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We analyzed our initial 100-case experience with the 3.5 cm artificial urinary sphincter cuff to identify risk factors for cuff erosion. Materials and Methods: We reviewed the records of a single surgeon, consecutive series of patients treated with 3.5 cm artificial urinary sphincter cuff placement from September 2009 to August 2013. Each patient underwent single perineal cuff placement via standardized technique. Preoperative characteristics, technical considerations and postoperative outcomes were analyzed and compared to those in a cohort of patients in whom a larger (4.0 cm or greater) artificial urinary sphincter cuff was placed during the same period. We identified clinical factors associated with an increased risk of 3.5 cm artificial urinary sphincter cuff erosion. Results: Of the 176 men who met study inclusion criteria during the 4-year period 100 (57%) received the 3.5 cm artificial urinary sphincter cuff and 76 (43%) received a larger cuff (4.0 cm or greater). The continence rate (83% vs 80%, p = 0.65) and mean followup (32 vs 25 months, p = 0.14) were similar in the 2 groups. Erosion developed in 16 of the 176 patients (9%) during the study period, of whom 13 had the 3.5 cm cuff. Of the 100 patients with the 3.5 cm cuff 52 (52%) had a history of radiation, including 11 (21%) with erosion. Cuff erosion developed only rarely in nonirradiated men (2 of 48 or 4%, p = 0.01). A history of radiation was the only significant risk factor associated with 3.5 cm cuff erosion (OR 6.2, 95% CI 1.3-29.5). Conclusions: Men with a history of radiation who underwent placement of a 3.5 cm artificial urinary sphincter cuff experienced an increased (21%) risk of cuff erosion.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 50 条
  • [31] WHEN TO SUSPECT ARTIFICIAL URINARY SPHINCTER CUFF EROSION: AN ANALYSIS OF PRESENTING SIGNS AND SYMPTOMS
    Diao, L.
    Nealon, S.
    Wolfe, A.
    Dropkin, B.
    Joice, G.
    Sanders, S.
    Hudak, S.
    Morey, A.
    JOURNAL OF SEXUAL MEDICINE, 2022, 19 (04): : S78 - S78
  • [32] ANDROGEN DEPRIVATION THERAPY IS ASSOCIATED WITH URETHRAL ATROPHY AND ARTIFICIAL URINARY SPHINCTER CUFF EROSION
    Davenport, Michael
    Akhtar, Abdulhadi
    Shakir, Nabeel
    Yi, Yooni
    Bergeson, Rachel
    Morey, Allen
    JOURNAL OF UROLOGY, 2019, 201 (04): : E573 - E573
  • [33] Comparison of 3.5 cm and transcorporal cuffs in high-risk artificial urinary sphincter populations
    Davenport, Michael T.
    Akhtar, Abdulhadi M.
    Shakir, Nabeel A.
    Baumgarten, Adam S.
    Yi, Yooni A.
    Bergeson, Rachel L.
    Ward, Ellen E.
    Morey, Allen F.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2020, 9 (01) : 62 - 66
  • [34] FUNCTIONAL RESULTS OF 3.5 CM CUFFS COMPARED TO OTHER CUFFS IN MEN WITH AN ARTIFICIAL URINARY SPHINCTER
    Weis, Sylvia
    Peyronnet, Benoit
    Bentellis, Imad
    Biardeau, Xavier
    Capon, Gregoire
    Lecoanet, Pierre
    Tricard, Thibault
    Bruyere, Franck
    Saussine, Christian
    Game, Xavier
    Cornu, Jean-Nicolas
    Hermieu, Nicolas
    JOURNAL OF UROLOGY, 2024, 211 (05): : E30 - E31
  • [35] THE CUFF EROSIONS IN PATIENTS WHO UNDERWENT ARTIFICIAL URINARY SPHINCTER IMPLANTATION
    Tuygun, Can
    Goktug, Goksel
    Demirel, Fuat
    Yigitbasi, Orhan
    Bakirtas, Hasan
    Imamoglu, Abdurrahim
    GAZI MEDICAL JOURNAL, 2009, 20 (01): : 30 - 32
  • [36] Is Risk of Artificial Urethral Sphincter Cuff Erosion Higher in Patients with Penile Prosthesis?
    Sundaram, Varun
    Cordon, Billy H.
    Hofer, Matthias D.
    Morey, Allen F.
    JOURNAL OF SEXUAL MEDICINE, 2016, 13 (09): : 1432 - 1437
  • [37] Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy
    Guralnick, ML
    Miller, E
    Toh, KL
    Webster, GD
    JOURNAL OF UROLOGY, 2002, 167 (05): : 2075 - 2078
  • [38] Most men with artificial urinary sphincter cuff erosion have low serum testosterone levels
    Wolfe, Avery R.
    Ortiz, Nicolas M.
    Baumgarten, Adam S.
    VanDyke, Maia E.
    West, Mary L.
    Dropkin, Benjamin M.
    Joice, Gregory A.
    Sanders, Sarah C.
    Hudak, Steven J.
    Morey, Allen F.
    NEUROUROLOGY AND URODYNAMICS, 2021, 40 (04) : 1035 - 1041
  • [39] NO CLEAR INDICATION FOR PENILE IMPLANT REMOVAL AT THE TIME OF ARTIFICIAL URINARY SPHINCTER EXPLANTATION FOR CUFF EROSION
    Gaines, Tyler M.
    Loh-Doyle, Jeffrey C.
    Maas, Marisa
    Markarian, Emily
    Michel, Joaquin
    Matluck, Nicole
    Cordon, Billy
    Klein, Roger
    Myrga, John
    Rusilko, Paul
    Livingston, Austin
    Grimaud, Logan
    Foreman, Jordan
    Lentz, Aaron
    Peterson, Andrew
    Mikhail, Mark
    Hwang, Alex
    Shridharani, Anand
    Tryfonyuk, Liliya
    Martins, Francisco
    Gonzalez, Rebecca
    Van Der Voort, Grant
    Bhalla, Rohan
    Flynn, Brian
    Nikolavsky, Dmitriy
    Simhan, Jay
    JOURNAL OF UROLOGY, 2024, 211 (05): : E1247 - E1247
  • [40] Is Removal of the Pressure-regulating Balloon Necessary After Artificial Urinary Sphincter Cuff Erosion?
    Rozanski, Alexander T.
    Viers, Boyd R.
    Shakir, Nabeel A.
    Pagliara, Travis J.
    Scott, Jeremy M.
    Morey, Allen F.
    UROLOGY, 2018, 113 : 225 - 229