The Stanford Volumetric Modulated Arc Therapy Total Body Irradiation Technique

被引:21
|
作者
Kovalchuk, Nataliya [1 ]
Simiele, Eric [1 ]
Skinner, Lawrie [1 ]
Yang, Yong [1 ]
Howell, Nicole [1 ]
Lewis, Jonathan [1 ]
Hui, Caressa [1 ]
Blomain, Erik [1 ]
Hoppe, Richard T. [1 ]
Hiniker, Susan M. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
BONE-MARROW-TRANSPLANTATION; RADIOTHERAPY; TBI;
D O I
10.1016/j.prro.2021.12.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this article, we describe the technical aspects of the Stanford volumetric modulated arc therapy (VMAT) total body irradiation (TBI) technique, compare it with other VMAT-TBI techniques, and share our initial experience. Methods and Materials: From September 2019 to August 2021, 35 patients were treated with VMAT-TBI at our institution. Treatment planning was performed using in-house developed automated planning scripts. Organ sparing depended on the regimen: myeloablative (lungs, kidneys, and lenses) and nonmyeloablative with benign disease (lungs, kidneys, lenses, gonads, brain, and thyroid). Quality assurance was performed using electronic portal imaging device portal dosimetry and Mobius3D. Robustness was evaluated for the first 10 patients by performing local and global isocenter shifts of 5 mm. Treatment was delivered using image-guided radiation therapy for every isocenter and every fraction. In vivo measurements were performed on the match line between the VMAT and anteriorposterior/posterior-anterior fields and on the testes for the first fraction. Results: The lungs, lungs - 1 cm, and kidneys D-mean were consistently spared to 57.6% +/- 4.4%, 40.7% +/- 5.5%, and 70.0% +/- 9.9% of the prescription dose, respectively. Gonadal sparing (D-mean = 0.69 +/- 0.13 Gy) was performed for all patients with benign disease. The average planning target volume (PTV) maximum dose to 1 cubic centimeter (D-1c(c)) was 120.7% +/- 6.4% for all patients. The average Gamma passing rate for the VMAT plans was 98.1% +/- 1.6% (criterion of 3%/2 mm). Minimal differences were observed between Mobius3D- and Eclipse AAA-calculated PTV D-mean (0.0% +/- 0.3%) and lungs D-mean (-2.5% +/- 1.2%). Robustness evaluation showed that the PTV D-max and lungs D-mean were insensitive to small positioning deviations between the VMAT isocenters (1.1% +/- 2.4% and 1.2% +/- 1.0%, respectively). The average match-line dose measurement indicated patient setup was reproducible (96.1% +/- 4.5% relative to prescription dose). Treatment time, including patient setup and beam-on, was 47.5 +/- 9.5 min. Conclusions: The Stanford VMAT-TBI technique, from simulation to treatment delivery, was presented and compared with other VMAT-TBI techniques. Together with publicly shared autoplanning scripts, our technique may provide the gateway for wider adaptation of this technology and the possibility of multi-institutional studies in the cooperative group setting. (C) 2022 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:245 / 258
页数:14
相关论文
共 50 条
  • [21] Volumetric Modulated Arc Therapy Based Total Body Irradiation - Five Year Clinical Experience
    Zhang-Velten, E. R.
    Parsons, D. D. M.
    Tan, J.
    Joo, M.
    Reynolds, R. R., Jr.
    Zhang, Y.
    Lee, H.
    Gu, X.
    Chambers, E.
    Timmerman, R. D.
    Desai, N. B.
    Dan, T.
    Kumar, K. A., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E753 - E753
  • [22] Clinical Outcomes of Image-Guided Volumetric Modulated Arc Therapy for Total Body Irradiation
    Kilic, S. S.
    Halima, A.
    Zhang, Z.
    Cho, Y. B.
    Magnelli, A.
    Kalaycio, M.
    Sauter, C. S.
    Sobecks, R.
    Hamilton, B.
    Rotz, S. J.
    Hanna, R.
    Murphy, E. S.
    Cherian, S.
    Xia, P.
    Guo, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S89 - S89
  • [23] Total body irradiation with volumetric modulated arc therapy: Dosimetric data and first clinical experience
    Andreas Springer
    Josef Hammer
    Erwin Winkler
    Christine Track
    Roswitha Huppert
    Alexandra Böhm
    Hedwig Kasparu
    Ansgar Weltermann
    Gregor Aschauer
    Andreas L. Petzer
    Ernst Putz
    Alexander Altenburger
    Rainer Gruber
    Karin Moser
    Karin Wiesauer
    Hans Geinitz
    Radiation Oncology, 11
  • [24] Linac-Based Total Body Irradiation (TBI) with Volumetric Modulated Arc Therapy (VMAT)
    Tas, B.
    Durmus, I. F.
    Okumus, A.
    Uzel, O. E.
    PROCEEDINGS OF THE TURKISH PHYSICAL SOCIETY 32ND INTERNATIONAL PHYSICS CONGRESS (TPS32), 2017, 1815
  • [25] Total body irradiation using volumetric modulated arc therapy, experience of a cancer hospital in Pakistan
    Sadaf, Tabinda
    Rashid, Asma
    Imam Bokhari, Waqas
    Samuel, Eileen
    Shahid, Aqueel
    Mukhtar, Raheel
    Zafar, Umair
    Iqbal, Khalid
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [26] Technical recommendations for implementation of Volumetric Modulated Arc Therapy and Helical Tomotherapy Total Body Irradiation
    Seravalli, Enrica
    Bosman, Mirjam E.
    Han, Chunhui
    Losert, Christoph
    Pazos, Montserrat
    Engstrom, Per E.
    Engellau, Jacob
    Fulcheri, Christian P. L.
    Zucchetti, Claudio
    Saldi, Simonetta
    Ferrer, Carlos
    Ocanto, Abrahams
    Hiniker, Susan M.
    Clark, Catharine H.
    Hussein, Mohammad
    Misson-Yates, Sarah
    Kobyzeva, Daria A.
    Loginova, Anna A.
    Hoeben, Bianca A. W.
    RADIOTHERAPY AND ONCOLOGY, 2024, 197
  • [27] Volumetric modulated arc therapy based Total Body Irradiation (TBI): a single center experience
    Mammini, F.
    Ammendolia, I.
    Deraco, E.
    Cavallini, L.
    Medici, F.
    Cicoria, G.
    Strolin, S.
    Paolani, G.
    Santoro, M.
    Strigari, L.
    Morganti, A. G.
    Cammelli, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S934 - S935
  • [28] Total Body Irradiation by Volumetric Modulated ARC Therapy for a Pediatric Patient with Acute Lymphoid Leukemia
    Lee, V.
    Hui, T.
    Lee, E.
    Chan, J.
    Kwong, D. L. W.
    Chen, Z. J.
    Lai, K.
    Lee, A. W. M.
    PEDIATRIC BLOOD & CANCER, 2018, 65 : S412 - S413
  • [29] The introduction of volumetric modulated arc therapy to total body irradiation (TBI) n first experiences
    Track, C.
    Hammer, J.
    Springer, A.
    Winkler, E.
    Weltermann, A.
    Boehm, A.
    Kasparu, H.
    Altenburger, A.
    Gruber, R.
    Geinitz, H.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S2 - S2
  • [30] Total body irradiation with volumetric modulated arc therapy: Dosimetric data and first clinical experience
    Springer, Andreas
    Hammer, Josef
    Winkler, Erwin
    Track, Christine
    Huppert, Roswitha
    Boehm, Alexandra
    Kasparu, Hedwig
    Weltermann, Ansgar
    Aschauer, Gregor
    Petzer, Andreas L.
    Putz, Ernst
    Altenburger, Alexander
    Gruber, Rainer
    Moser, Karin
    Wiesauer, Karin
    Geinitz, Hans
    RADIATION ONCOLOGY, 2016, 11