The Stanford Volumetric Modulated Arc Therapy Total Body Irradiation Technique

被引:21
|
作者
Kovalchuk, Nataliya [1 ]
Simiele, Eric [1 ]
Skinner, Lawrie [1 ]
Yang, Yong [1 ]
Howell, Nicole [1 ]
Lewis, Jonathan [1 ]
Hui, Caressa [1 ]
Blomain, Erik [1 ]
Hoppe, Richard T. [1 ]
Hiniker, Susan M. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
BONE-MARROW-TRANSPLANTATION; RADIOTHERAPY; TBI;
D O I
10.1016/j.prro.2021.12.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this article, we describe the technical aspects of the Stanford volumetric modulated arc therapy (VMAT) total body irradiation (TBI) technique, compare it with other VMAT-TBI techniques, and share our initial experience. Methods and Materials: From September 2019 to August 2021, 35 patients were treated with VMAT-TBI at our institution. Treatment planning was performed using in-house developed automated planning scripts. Organ sparing depended on the regimen: myeloablative (lungs, kidneys, and lenses) and nonmyeloablative with benign disease (lungs, kidneys, lenses, gonads, brain, and thyroid). Quality assurance was performed using electronic portal imaging device portal dosimetry and Mobius3D. Robustness was evaluated for the first 10 patients by performing local and global isocenter shifts of 5 mm. Treatment was delivered using image-guided radiation therapy for every isocenter and every fraction. In vivo measurements were performed on the match line between the VMAT and anteriorposterior/posterior-anterior fields and on the testes for the first fraction. Results: The lungs, lungs - 1 cm, and kidneys D-mean were consistently spared to 57.6% +/- 4.4%, 40.7% +/- 5.5%, and 70.0% +/- 9.9% of the prescription dose, respectively. Gonadal sparing (D-mean = 0.69 +/- 0.13 Gy) was performed for all patients with benign disease. The average planning target volume (PTV) maximum dose to 1 cubic centimeter (D-1c(c)) was 120.7% +/- 6.4% for all patients. The average Gamma passing rate for the VMAT plans was 98.1% +/- 1.6% (criterion of 3%/2 mm). Minimal differences were observed between Mobius3D- and Eclipse AAA-calculated PTV D-mean (0.0% +/- 0.3%) and lungs D-mean (-2.5% +/- 1.2%). Robustness evaluation showed that the PTV D-max and lungs D-mean were insensitive to small positioning deviations between the VMAT isocenters (1.1% +/- 2.4% and 1.2% +/- 1.0%, respectively). The average match-line dose measurement indicated patient setup was reproducible (96.1% +/- 4.5% relative to prescription dose). Treatment time, including patient setup and beam-on, was 47.5 +/- 9.5 min. Conclusions: The Stanford VMAT-TBI technique, from simulation to treatment delivery, was presented and compared with other VMAT-TBI techniques. Together with publicly shared autoplanning scripts, our technique may provide the gateway for wider adaptation of this technology and the possibility of multi-institutional studies in the cooperative group setting. (C) 2022 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:245 / 258
页数:14
相关论文
共 50 条
  • [1] Volumetric Modulated Arc Therapy for Total Body Irradiation
    Ouyang, L.
    Folkerts, M.
    Hrycushko, B.
    Lamphier, R.
    Lee, H.
    Yan, Y.
    Jiang, S.
    Timmerman, R.
    Desai, N.
    Abulrahman, R.
    Gu, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3896 - 3896
  • [2] Improved organ sparing using auto-planned Stanford volumetric modulated arc therapy for total body irradiation technique
    Ngo, Nicholas
    Blomain, Erik S.
    Simiele, Eric
    Romero, Ignacio
    Hoppe, Richard T.
    Hiniker, Susan M.
    Kovalchuk, Nataliya
    PEDIATRIC BLOOD & CANCER, 2023, 70 (10)
  • [3] Treatment robustness of total body irradiation with volumetric modulated arc therapy
    Seravalli, Enrica
    Willemsen-Bosman, Mirjam
    Zoetelief, Annelies
    Roosenboom, Sanne
    Harderwijk, Tessa
    Krikke, Lean
    Bol, Gijsbert
    Kotte, Alexis
    Huijboom, Eline
    van Loon, Karel
    Hoeben, Bianca
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [4] First clinical experience of total body irradiation using volumetric modulated arc therapy technique in Japan
    Nozawa, Yuki
    Yamashita, Hideomi
    Sawayanagi, Subaru
    Katano, Atsuto
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2025, 21 (01) : 237 - 239
  • [5] Dose planning of a total body irradiation with Volumetric Modulated Arc Therapy (VMAT)
    Springer, A.
    Winkler, E.
    Putz, E.
    Altenburger, A.
    Gruber, R.
    Moser, K.
    Track, C.
    Hammer, J.
    Geinitz, H.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [6] Investigation of Volumetric Modulated Arc Therapy for Total Body Irradiation with Lung Blocks
    Wang, H.
    Tung, S.
    Wang, C.
    Mahajan, A.
    Dabaja, B.
    Martel, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Total Marrow Irradiation: A Clinical Evaluation of a Volumetric Modulated Arc Therapy Technique
    Cozzi, L.
    Mancosu, P.
    Navarria, P.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Fogliata, A.
    Ibatici, A.
    Santoro, A.
    Scorsetti, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S93 - S93
  • [8] Total Body Irradiation (TBI) by Volumetric Modulated Arc Therapy: First Experiences and Perspectives
    Hammer, J.
    Springer, A.
    Track, C.
    Winkler, E.
    Boehm, A.
    Kasparu, H.
    Weltermann, A.
    Altenburger, A.
    Gruber, R.
    Geinitz, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S682 - S682
  • [9] Feasibility study of volumetric modulated arc therapy with Halcyon™ linac for total body irradiation
    Takuya Uehara
    Hajime Monzen
    Mikoto Tamura
    Masahiro Inada
    Masakazu Otsuka
    Hiroshi Doi
    Kenji Matsumoto
    Yasumasa Nishimura
    Radiation Oncology, 16
  • [10] Failure Mode and Effect Analysis for Volumetric Modulated Arc Therapy for Total Body Irradiation
    Gray, T.
    Antolak, A.
    Ahmed, S.
    Magnelli, A.
    Lu, L.
    Cho, Y.
    Xia, P.
    Guo, B.
    MEDICAL PHYSICS, 2021, 48 (06)