Detection of NH3 by quartz crystal microbalance with SnxNiy coating

被引:0
|
作者
Georgieva, V. [1 ]
Stefchev, P. [2 ]
Stefanov, P. [3 ]
Kirilov, R. [2 ]
Dikov, C. [2 ]
Gadjanova, V. [1 ]
Atanassov, D. M. [1 ]
机构
[1] Bulgarian Acad Sci, Inst Solid State Phys, BU-1784 Sofia, Bulgaria
[2] Bulgarian Acad Sci, Cent Lab Solar Energy & New Energy Sources, BU-1784 Sofia, Bulgaria
[3] Bulgarian Acad Sci, Inst Gen & Inorgan Chem, BU-1113 Sofia, Bulgaria
来源
关键词
Thin films; QCM sensor; NH3 gas adsorption;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the gas-sensing properties of bimetallic structures of Sn and Ni to NH3 are investigated using Quartz Crystal Microbalance (QCM). The 16 MHz QCM are created on AT-cut quartz with gold electrodes (4mm diameter). The bimetallic layers are prepared by cathode electro-deposition on QCM. Special electro-chemical cells are constructed to investigate the electro deposition process. Nickel is used as anode and the optimal current density is 3 A/dm(2). After electro deposition the coatings are treated at 200 degrees C for one hour in air environment. The coatings are investigated by Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD) and X-ray Photoelectron Spectroscopy (XPS) methods. SEM micrographs of the coatings show that they consist of a highly branching layer of bimetallic needles. The structure investigation of coatings indicate dendrite ones consisting of different SnxNiy crystalline phases and Sn. The sorption properties of SnxNiy coatings to NH3 are studied in dynamic regime. The frequency-time characteristics (FTCs) of the system QCM-SnxNiy are measured. The changes of the frequency from 5Hz to 77Hz are defined for 10ppm and 1000ppm respectively. The maximum frequency shift and mass-loading are determineded. It is obtained that SnxNiy coatings possess sorption ability to NH3 and can be successful used as sensor element for NH3.
引用
收藏
页码:1957 / 1961
页数:5
相关论文
共 50 条
  • [31] BACTERIAL IMMOBILIZATION AT GOLD SURFACES - DETECTION WITH THE QUARTZ CRYSTAL MICROBALANCE
    FAXON, AR
    BUTTRY, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 324 - COLL
  • [32] Mass-sensitive detection of oligonucleotides by quartz crystal microbalance
    Ketterer, T
    Rickert, J
    Bayer, E
    Göpel, W
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 816 - 818
  • [33] Detection of sulfur dioxide using a piezoelectric quartz crystal microbalance
    Guimaraes, OM
    ANALYTICAL LETTERS, 1997, 30 (12) : 2159 - 2174
  • [34] Quartz crystal microbalance sensor for detection of aliphatic amines vapours
    Ayad, Mohamad M.
    Torad, Nagy L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (02) : 481 - 487
  • [35] Aliphatic amines vapours detection by quartz crystal microbalance sensor
    Das, Rashmita
    Pradhan, Susmita
    Biswas, Sudip
    Sharma, Prolay
    Ghosh, Arunangshu
    Bandyopadhyay, Rajib
    Pramanik, Panchanan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 94 - 101
  • [36] Quartz crystal microbalance biosensor for rapid detection of aerosolized microorganisms
    Farka, Zdenek
    Kovar, David
    Skladal, Petr
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XVI, 2015, 9455
  • [37] Noise in Quartz Crystal Microbalance
    Sedlak, Petr
    Sikula, Josef
    Majzner, Jiri
    Vrnata, Martin
    Vyslouzil, Filip
    Fitl, Premysl
    Kopecky, Dusan
    Handel, Peter H.
    2011 21ST INTERNATIONAL CONFERENCE ON NOISE AND FLUCTUATIONS (ICNF), 2011, : 336 - 339
  • [38] Quartz Crystal Microbalance with Dissipation
    不详
    TENSIDE SURFACTANTS DETERGENTS, 2009, 46 (02) : 121 - 121
  • [39] Multimode quartz crystal microbalance
    Goka, Shigeyoshi
    Okabe, Kiwamu
    Watanabe, Yasuaki
    Sekimoto, Hitoshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (5 B): : 3073 - 3075
  • [40] A quartz crystal microbalance sensor for the detection of formic acid vapors
    C. García-Verdugo-Caso
    J. L. Hidalgo-Hidalgo-de-Cisneros
    I. Naranjo-Rodríguez
    D. Bellido-Milla
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 393 - 398