Investigation of corneal biomechanics using Ocular Response Analyzer® and Corvis® ST in diabetes mellitus

被引:0
|
作者
Ramm, Lisa [1 ]
Herber, Robert [1 ]
Spoerl, Eberhard [1 ]
Terai, Naim [1 ]
Pillunat, Lutz E. [1 ]
机构
[1] Univ Carl Gustav Carus TU Dresden, Ophthalmol, Dresden, Germany
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
1383
引用
下载
收藏
页数:2
相关论文
共 50 条
  • [1] Measurement of Corneal Biomechanical Properties in Diabetes Mellitus Using the Ocular Response Analyzer and the Corvis ST
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Pillunat, Lutz E.
    Terai, Naim
    CORNEA, 2019, 38 (05) : 595 - 599
  • [2] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Ramin Salouti
    Reza Razeghinejad
    Nasrin Masihpour
    Maryam Ghoreyshi
    M. Hossein Nowroozzadeh
    International Ophthalmology, 2020, 40 : 2563 - 2567
  • [3] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [4] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Salouti, Ramin
    Razeghinejad, Reza
    Masihpour, Nasrin
    Ghoreyshi, Maryam
    Nowroozzadeh, M. Hossein
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2563 - 2567
  • [5] Measurement of corneal biomechanical properties in diabetes mellitus using the Corvis ST
    Ohn, Kyoung
    Noh, Young Ho
    Moon, Jung Il
    Jung, Younhea
    MEDICINE, 2022, 101 (36) : E30248
  • [6] Biomechanics of the Cornea Evaluated by Spectral Analysis of Waveforms from Ocular Response Analyzer and Corvis-ST
    Tejwani, Sushma
    Shetty, Rohit
    Kurien, Mathew
    Dinakaran, Shoruba
    Ghosh, Arkasubhra
    Roy, Abhijit Sinha
    PLOS ONE, 2014, 9 (08):
  • [7] Intraocular Pressure Before and After Corneal Refractive Surgery: A Prospective Comparison of Corvis ST and Ocular Response Analyzer
    Salouti, Ramin
    Azimi, Ali
    Meshksar, Aidin
    Takapouy, Ramin
    Ghoreyshi, Maryam
    Salouti, Kia
    Razeghinejad, Reza
    Nowroozzadeh, Mohammad Hossein
    JOURNAL OF GLAUCOMA, 2024, 33 (10) : 780 - 784
  • [8] Evaluation of changes in corneal biomechanics after orthokeratology using Corvis ST
    Zhang, PeiPei
    Wu, JinFang
    Jiang, Jun
    Zhang, XinYu
    Ran, ZiYing
    Jiang, Fan
    Zheng, XiaoBo
    Wang, JunJie
    Elsheikh, Ahmed
    Bao, FangJun
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (01):
  • [9] Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [10] CORNEAL BIOMECHANICS: EVALUATING PURE CORNEAL DEFORMATION IN KERATOCONIC AND NORMAL EYES USING THE CORVIS ST
    Vellara, Hans
    Ali, Noor
    Patel, Dipika
    McGhee, Charles
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 : 69 - 69