Measurement of Corneal Biomechanical Properties in Diabetes Mellitus Using the Ocular Response Analyzer and the Corvis ST

被引:25
|
作者
Ramm, Lisa [1 ]
Herber, Robert [1 ]
Spoerl, Eberhard [1 ]
Pillunat, Lutz E. [1 ]
Terai, Naim [1 ]
机构
[1] Univ Hosp Dresden, Dept Ophthalmol, Dresden, Germany
关键词
ocular response analyzer; Corvis ST; biomechanics; diabetes mellitus; INTRAOCULAR-PRESSURE; IN-VIVO; NONENZYMATIC GLYCATION; KERATOCONUS; PARAMETERS; PACHYMETRY; HEALTHY;
D O I
10.1097/ICO.0000000000001879
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Hyperglycemia in diabetes mellitus (DM) might induce changes in corneal biomechanics. Therefore, biomechanical properties of the cornea were measured using the ocular response analyzer and the Corvis ST. Methods: In the study, 35 eyes of 35 diabetic patients were included. After an ophthalmological examination, measurements with the ocular response analyzer and the Corvis ST were taken. Additionally, biometry and corneal topography were performed and HbA1c values were collected. Results were compared to an age-, pachymetry-and intraocular pressure-matched group of 35 healthy subjects. Results: Mean age (67.6 6 10.3; 64.1 6 8.3 years), intraocular pressure (13.4 6 2.9; 12.8 6 2.8 mm Hg), and central corneal thickness (556.4 6 31.7; 548.6 6 32.9 mm) were not significantly different between the groups (P. 0.05). In DM, the corneal hysteresis (CH) and the corneal resistance factor (CRF) were increased (CH: 10.8 6 2 vs. 9.4 6 1.6, P = 0.002; CRF: 10.6 6 2.1 vs. 9.6 6 1.5, P = 0.022). Also, most dynamic corneal response parameters showed significant differences. Beside others, A1 and A2 deflection amplitudes were increased (P, 0.001) and highest concavity and A2 time were extended (P, 0.001 and 0.007) in DM. According to current HbA1c value, DM was classified as controlled (# 7%) and poorly controlled (. 7%) and significant biomechanical differences were measured between both groups. Conclusions: In DM, significant changes in corneal biomechanical properties were detectable. In patients, CH and CRF were increased and most dynamic corneal response parameters were different compared to healthy subjects.
引用
下载
收藏
页码:595 / 599
页数:5
相关论文
共 50 条
  • [1] Measurement of corneal biomechanical properties in diabetes mellitus using the Corvis ST
    Ohn, Kyoung
    Noh, Young Ho
    Moon, Jung Il
    Jung, Younhea
    MEDICINE, 2022, 101 (36) : E30248
  • [2] Investigation of corneal biomechanics using Ocular Response Analyzer® and Corvis® ST in diabetes mellitus
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Terai, Naim
    Pillunat, Lutz E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Ramin Salouti
    Reza Razeghinejad
    Nasrin Masihpour
    Maryam Ghoreyshi
    M. Hossein Nowroozzadeh
    International Ophthalmology, 2020, 40 : 2563 - 2567
  • [4] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Salouti, Ramin
    Razeghinejad, Reza
    Masihpour, Nasrin
    Ghoreyshi, Maryam
    Nowroozzadeh, M. Hossein
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2563 - 2567
  • [5] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [6] Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [7] Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients
    Ramm, Lisa
    Herber, Robert
    Lorenz, Georg
    Jasper, Carolin S.
    Pillunat, Lutz E.
    Pillunat, Karin R.
    PLOS ONE, 2023, 18 (01):
  • [8] Determination of Corneal Nonlinear Viscoelastic Biomechanical Properties using Corvis ST
    Zhalgas, Aidana
    Ko, Match W. L.
    Kim, Jong R.
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2019, : 634 - 637
  • [9] Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer
    Detry-Morel, Michele
    Jamart, Jacques
    Pourjavan, Saveh
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 138 - 148
  • [10] Measurement of Orbital Biomechanical Properties in Patients with Thyroid Orbitopathy Using the Dynamic Scheimpflug Analyzer (Corvis ST)
    Leszczynska, Anna
    Moehler, Karolin
    Spoerl, Eberhard
    Ramm, Lisa
    Herber, Robert
    Pillunat, Lutz E.
    Terai, Naim
    CURRENT EYE RESEARCH, 2018, 43 (03) : 289 - 292