Host tissue response to floating microelectrode arrays chronically implanted in the feline spinal nerve

被引:6
|
作者
Kolarcik, Christi L. [1 ,2 ,3 ,4 ,5 ,9 ]
Castro, Carlos A. [6 ]
Lesniak, Andrew [7 ]
Demetris, Anthony J. [4 ,7 ]
Fisher, Lee E. [1 ,2 ,3 ,8 ]
Gaunt, Robert A. [1 ,2 ,3 ,8 ]
Weber, Douglas J. [1 ,2 ,3 ,4 ,8 ]
Cui, X. Tracy [1 ,2 ,3 ,4 ,10 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, 3520 Fifth Ave,Room 306, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Ctr Neural Basis Cognit, Pittsburgh, PA 15213 USA
[3] Carnegic Mellon Univ, Pittsburgh, PA 15213 USA
[4] McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[5] Syst Neurosci Ctr, Pittsburgh, PA USA
[6] Magee Womens Res Inst, Pittsburgh, PA USA
[7] Univ Pittsburgh, Sch Med, Dept Pathol, Pittsburgh, PA 15213 USA
[8] Univ Pittsburgh, Dept Phys Med & Rehabil, Pittsburgh, PA 15213 USA
[9] Univ Pittsburgh, Live Like Lou Ctr ALS Res, Dept Neurobiol, Pittsburgh, PA 15213 USA
[10] Univ Pittsburgh, Dept Bioengn, 5057 Biomed Sci Tower 3,3501 Fifth Ave, Pittsburgh, PA 15260 USA
关键词
dorsal root ganglion; ventral root; tissue; electrode interface; neuroprosthesis; chronic implantation; BRAIN-TISSUE; ULNAR NERVE; ELECTRODES; CELLS; STIMULATION; COMPONENTS; INTERFACE; FLEXION; GANGLIA; IMPACT;
D O I
10.1088/1741-2552/ab94d7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Neural interfacing technologies could significantly improve quality of life for people living with the loss of a limb. Both motor commands and sensory feedback must be considered; these complementary systems are segregated from one another in the spinal nerve.Approach. The dorsal root ganglion-ventral root (DRG-VR) complex was targeted chronically with floating microelectrode arrays designed to record from motor neuron axons in the VR or stimulate sensory neurons in the DRG. Hematoxylin and eosin and Nissl/Luxol fast blue staining were performed. Characterization of the tissue response in regions of interest and pixel-based image analyses were used to quantify MAC387 (monocytes/macrophages), NF200 (axons), S100 (Schwann cells), vimentin (fibroblasts, endothelial cells, astrocytes), and GLUT1 (glucose transport proteins) reactivity. Implanted roots were compared to non-implanted roots and differences between the VR and DRG examined.Main results. The tissue response associated with chronic array implantation in this peripheral location is similar to that observed in central nervous system locations. Markers of inflammation were increased in implanted roots relative to control roots with MAC387 positive cells distributed throughout the region corresponding to the device footprint. Significant decreases in neuronal density and myelination were observed in both the VR, which contains only neuronal axons, and the DRG, which contains both neuronal axons and cell bodies. Notably, decreases in NF200 in the VR were observed only at implant times less than ten weeks. Observations related to the blood-nerve barrier and tissue integrity suggest that tissue remodeling occurs, particularly in the VR.Significance. This study was designed to assess the viability of the DRG-VR complex as a site for neural interfacing applications and suggests that continued efforts to mitigate the tissue response will be critical to achieve the overall goal of a long-term, reliable neural interface.
引用
收藏
页数:18
相关论文
共 34 条
  • [21] In-vivo evaluation of chronically implanted neural microelectrode arrays modified with poly (3,4-ethylenedioxythiophene) nanotubes
    Abidian, Mohammad Reza
    Salas, Luis G.
    Yazdan-Shahmorad, Azadeh
    Marzullo, Timothy C.
    Martin, David C.
    Kipke, Daryl R.
    2007 3RD INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, VOLS 1 AND 2, 2007, : 61 - +
  • [22] Networks of spinal cord neurons cultured on microelectrode arrays: response to stimuli and homeostasis
    Chiappalone, M
    Davide, F
    Grattarola, M
    Pasa, S
    Maura, G
    Marcoli, M
    Tedesco, M
    ISPA 2001: PROCEEDINGS OF THE 2ND INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, 2001, : 645 - 649
  • [23] Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays
    He, Wei
    McConnell, George C.
    Bellamkonda, Ravi V.
    JOURNAL OF NEURAL ENGINEERING, 2006, 3 (04) : 316 - 326
  • [24] Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex
    Winslow, Brent D.
    Tresco, Patrick A.
    BIOMATERIALS, 2010, 31 (07) : 1558 - 1567
  • [25] Restoration From Acute Urinary Dysfunction Using Utah Electrode Arrays Implanted Into the Feline Pudendal Nerve
    Wark, Heather Anna Cary
    Black, Shana R.
    Mathews, Kiran Serah
    Cartwright, Patrick C.
    Gustafson, Kenneth J.
    Normann, Richard Alan
    NEUROMODULATION, 2015, 18 (04): : 317 - 323
  • [26] MICROSTRUCTURE OF IMPLANTED MEMBRANES DIRECTS HOST TISSUE-RESPONSE
    BRAUKER, J
    MARTINSON, LA
    YOUNG, SK
    CARRBRENDEL, VE
    JOHNSON, RC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 113 - PMSE
  • [27] Angiogenic and inflammatory host tissue response to implanted surgical meshes
    Haeufel, J. M.
    Laschke, M. W.
    Menger, M. D.
    JOURNAL OF VASCULAR RESEARCH, 2006, 43 (06) : 565 - 565
  • [28] Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord
    Ersen, Ali
    Elkabes, Stella
    Freedman, David S.
    Sahin, Mesut
    JOURNAL OF NEURAL ENGINEERING, 2015, 12 (01)
  • [29] Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve
    Wark, H. A. C.
    Mathews, K. S.
    Normann, R. A.
    Fernandez, E.
    JOURNAL OF NEURAL ENGINEERING, 2014, 11 (04)
  • [30] Effect of Insertion Speed on Tissue Response and Insertion Mechanics of a Chronically Implanted Silicon-Based Neural Probe
    Welkenhuysen, M.
    Andrei, A.
    Ameye, L.
    Eberle, W.
    Nuttin, B.