Relationship between Behavioral and Objective Measures of Sound Intensity in Normal-Hearing Listeners and Hearing-Aid Users: A Pilot Study

被引:4
|
作者
Legris, Elsa [1 ,2 ]
Galvin, John [1 ,3 ]
Mofid, Yassine [1 ]
Aguillon-Hernandez, Nadia [1 ]
Roux, Sylvie [1 ]
Aoustin, Jean-Marie [2 ]
Gomot, Marie [1 ]
Bakhos, David [1 ,2 ,3 ]
机构
[1] Univ Francois Rabelais Tours, INSERM, UMR S1253, F-37000 Tours, France
[2] CHRU Tours, Ear Nose & Throat Dept, F-37000 Tours, France
[3] House Inst Fdn, Los Angeles, CA 90057 USA
关键词
loudness perception; hearing aid; cortical auditory evoked potential; pupillometry; objective measures; AUDITORY-EVOKED-POTENTIALS; SPECTRAL LOUDNESS SUMMATION; PUPILLARY RESPONSES; COCHLEAR IMPLANTATION; SPEECH-PERCEPTION; NOISE-REDUCTION; PUPILLOMETRY; DILATION; CHILDREN; LATENCY;
D O I
10.3390/brainsci12030392
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: For hearing-impaired individuals, hearing aids are clinically fit according to subjective measures of threshold and loudness. The goal of this study was to evaluate objective measures of loudness perception that might benefit hearing aid fitting. Method: Seventeen adult hearing aid users and 17 normal-hearing adults participated in the study. Outcome measures including categorical loudness scaling, cortical auditory evoked potentials (CAEPs), and pupillometry. Stimuli were 1-kHz tone bursts presented at 40, 60, and 80 dBA. Results: Categorical loudness scaling showed that loudness significantly increased with intensity for all participants (p < 0.05). For CAEPs, high intensity was associated with greater P1, N1, and P2 peak amplitude for all listeners (p < 0.05); a significant but small effect of hearing aid amplification was observed. For all participants, pupillometry showed significant effects of high intensity on pupil dilation (p < 0.05); there was no significant effect of hearing aid amplification. A Focused Principal Component analysis revealed significant correlations between subjective loudness and some of the objective measures. Conclusion: The present data suggest that intensity had a significant impact on loudness perception, CAEPs, and pupil response. The correlations suggest that pupillometry and/or CAEPs may be useful in determining comfortable amplification for hearing aids.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Intensity discrimination and auditory brainstem responses in cochlear implant and normal-hearing listeners
    Gallego, S
    Micheyl, C
    BEHAVIORAL NEUROSCIENCE, 1998, 112 (04) : 793 - 799
  • [32] Speech recognition by normal-hearing and cochlear implant listeners as a function of intensity resolution
    Loizou, PC
    Dorman, M
    Poroy, O
    Spahr, T
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (05): : 2377 - 2387
  • [33] Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners
    Brons, Inge
    Dreschler, Wouter A.
    Houben, Rolph
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 136 (03): : 1375 - 1384
  • [34] Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners
    Brons, Inge (I.Brons@amc.uva.nl), 1600, Acoustical Society of America (136):
  • [35] Sound Quality Effects of an Adaptive Nonlinear Frequency Compression Processor with Normal-Hearing and Hearing-Impaired Listeners
    Glista, Danielle
    Hawkins, Marianne
    Vaisberg, Jonathan M.
    Pourmand, Nazanin
    Parsa, Vijay
    Scollie, Susan
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2019, 30 (07) : 552 - 563
  • [36] Effects of degradation of intensity, time, or frequency content on speech intelligibility for normal-hearing and hearing-impaired listeners
    van Schijndel, NH
    Houtgast, T
    Festen, JM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 110 (01): : 529 - 542
  • [37] Haptic sound-localisation for use in cochlear implant and hearing-aid users
    Fletcher, Mark D.
    Zgheib, Jana
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [38] Haptic sound-localisation for use in cochlear implant and hearing-aid users
    Mark D. Fletcher
    Jana Zgheib
    Scientific Reports, 10
  • [39] Effects of amplitude nonlinearity on phoneme recognition by cochlear implant users and normal-hearing listeners
    Fu, QJ
    Shannon, RV
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (05): : 2570 - 2577
  • [40] Normal-Hearing Listeners' and Cochlear Implant Users' Perception of Pitch Cues in Emotional Speech
    Gilbers, Steven
    Fuller, Christina
    Gilbers, Dicky
    Broersma, Mirjam
    Goudbeek, Martijn
    Free, Rolien
    Baskent, Deniz
    I-PERCEPTION, 2015, 6 (05): : 1 - 19