Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger

被引:3
|
作者
Intra, Panich [1 ]
Yawootti, Artit [1 ]
Vinitketkumnuen, Usanee [2 ]
Tippayawong, Nakorn [3 ]
机构
[1] Rajamangala Univ Technol Lanna, Coll Integrated Sci & Technol, Chiang Mai, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Biochem, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai 50200, Thailand
关键词
Aerosol; Charger; Unipolar charging; Corona discharge; DIFFUSION CHARGER; PERFORMANCE; PARTICLES;
D O I
10.5370/JEET.2011.6.4.556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present study, a simple corona-wire charger for unipolar diffusion charging of aerosol particles is designed, constructed, and characterized. Experimental characterizations of the electrostatic discharge in terms of current-voltage relationships of positive and negative coronas of the corona-wire charger are also presented and discussed. The charging current and ion concentration in the charging zone increased monotonically with corona voltage. The negative corona showed higher current than the positive corona. At the same corona voltages, the current in the discharge zone is about 600 times larger than the charging current. The ion number concentrations ranged within approximately 5.0 x 10(10) to 1.24 x 10(16) and 4.5 x 10(12) to 2 x 10(16) ions/m(3) in the discharge and charging zones, respectively. A numerical model is used to predict the behavior of the electric potential lines. Numerical results of ion penetration through the inner electrode are in good agreement with the experimental results.
引用
下载
收藏
页码:556 / 562
页数:7
相关论文
共 50 条