Quantitative phase and refractive index measurements with point-source digital in-line holographic microscopy

被引:55
|
作者
Jericho, M. H. [1 ]
Kreuzer, H. J. [1 ]
Kanka, M. [2 ]
Riesenberg, R. [2 ]
机构
[1] Dalhousie Univ, Dept Phys & Atmospher Sci, Halifax, NS B3H 3J5, Canada
[2] Inst Photon Technol, D-07747 Jena, Germany
基金
加拿大自然科学与工程研究理事会;
关键词
RECONSTRUCTION;
D O I
10.1364/AO.51.001503
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Point-source digital in-line holographic microscopy with numerical reconstruction is ideally suited for quantitative phase measurements to determine optical path lengths and to extract changes in refractive index within accuracy close to 0.001 on the submicrometer length scale. This is demonstrated with simulated holograms and with detailed measurements on a number of different micrometer-sized samples such as suspended drops, optical fibers, as well as organisms of biological interest such as E. coli bacteria, HeLa cells, and fibroblast cells. (C) 2012 Optical Society of America
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 50 条
  • [11] Measurement of refractive index change induced by dark reaction of photopolymer with digital holographic quantitative phase microscopy
    Arimoto, Hidenobu
    Watanabe, Wataru
    Masaki, Kazuyoshi
    Fukuda, Takashi
    OPTICS COMMUNICATIONS, 2012, 285 (24) : 4911 - 4917
  • [12] Dual plane in-line digital holographic microscopy
    Das, Bhargab
    Yelleswarapu, Chandra S.
    OPTICS LETTERS, 2010, 35 (20) : 3426 - 3428
  • [13] Coherence effects in digital in-line holographic microscopy
    Gopinathan, Unnikrishnan
    Pedrini, Giancarlo
    Osten, Wolfgang
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (10) : 2459 - 2466
  • [14] Variable zoom digital in-line holographic microscopy
    Sanz, Martin
    Trusiak, Maciej
    Garcia, Javier
    Mico, Vicente
    OPTICS AND LASERS IN ENGINEERING, 2020, 127
  • [15] Refractive index measurements of single, spherical cells using digital holographic microscopy
    Schuermann, Mirjam
    Scholze, Jana
    Mueller, Paul
    Chan, Chii J.
    Ekpenyong, Andrew E.
    Chalut, Kevin J.
    Guck, Jochen
    BIOPHYSICAL METHODS IN CELL BIOLOGY, 2015, 125 : 143 - 159
  • [16] Extraction of 3D Axial Features in Programmable Point-Source Digital In-Line Holographic Microscope with Spherical Reference Field
    Adeyemi, Adekunle A.
    Darcie, Thomas E.
    2009 IEEE PACIFIC RIM CONFERENCE ON COMMUNICATIONS, COMPUTERS AND SIGNAL PROCESSING, VOLS 1 AND 2, 2009, : 736 - 739
  • [17] Holographic point source for digital lensless holographic microscopy
    Lopera, Maria J.
    Trujillo, Carlos
    OPTICS LETTERS, 2022, 47 (11) : 2862 - 2865
  • [18] Cell refractive index tomography by digital holographic microscopy
    Charrière, F
    Marian, A
    Montfort, F
    Kuehn, J
    Colomb, T
    Cuche, E
    Marquet, P
    Depeursinge, C
    OPTICS LETTERS, 2006, 31 (02) : 178 - 180
  • [19] Digital in-line holographic microscopy applied to microfluidic studies
    Garcia-Sucerquia, J.
    Xu, W.
    Jericho, S. K.
    Jericho, M. H.
    Kreuzer, H. J.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112
  • [20] Quantitative phase imaging of low-cost digital in-line holography in comparison with off-axis digital holographic microscopy
    Ram, G. Hanu Phani
    John, Renu
    UNCONVENTIONAL OPTICAL IMAGING, 2018, 10677