A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers

被引:71
|
作者
Pereira, Claudete Fernandes [1 ]
Pimentel, Maria Fernanda [1 ]
Harrop Galvao, Roberto Kawakami [2 ]
Honorato, Fernanda Araujo [1 ]
Stragevitch, Luiz [1 ]
Martins, Marcelo Nascimento [2 ]
机构
[1] Univ Fed Pernambuco, Dept Engn Quim, Recife, PE, Brazil
[2] Inst Tecnol Aeronaut, Div Engn Eletron, Sao Jose Dos Campos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
calibration transfer; standardization methods; chemometrics; near infrared spectrometry; gasoline;
D O I
10.1016/j.aca.2008.01.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a comparative study of calibration transfer among three near infrared spectrometers for determination of naphthenes and RON (Research Octane Number) in gasoline. Seven transfer methods are compared: direct standardization (DS), piecewise direct standardization (PDS), orthogonal signal correction (OSC), reverse standardization (RS), piecewise reverse standardization (PRS), slope and bias correction (SBC) and model updating (MU). Two pre-treatment procedures, namely standard normal variate (SNV) and multiplicative scatter correction (MSC), are also investigated. The choice of an appropriate number of transfer samples for each technique, as well as the effect of window size in PDS/PRS and OSC components, are discussed. Abroad set of gasoline samples representative of the Northeastern states of Brazil is employed in the investigation. The results show that the use of calibration transfer yields prediction errors comparable to those obtained with complete recalibration of the secondary instrument. Overall, the results point to RS as the best method for the analytical problem under consideration. When storage and/or physical transportation of transfer samples are impractical, MU is more appropriate. The comprehensive investigation carried out in the present work will be of value for practitioners involved in networks of fuel monitoring. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [41] Transfer of near infrared calibration for gasoline octane number based on screening consistent wavelengths combined with direct standardization algorithm
    Wang, Honghong
    Yuan, Hui
    Xiong, Zhixin
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2024, 32 (1-2) : 38 - 45
  • [42] Are standard sample measurements still needed to transfer multivariate calibration models between near-infrared spectrometers? The answer is not always
    Mishra, Puneet
    Nikzad-Langerodi, Ramin
    Marini, Federico
    Roger, Jean Michel
    Biancolillo, Alessandra
    Rutledge, Douglas N.
    Lohumi, Santosh
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 143
  • [43] Calibration transfer between miniature photodiode array-based spectrometers in the near infrared assessment of mandarin soluble solids content
    Greensill, CV
    Walsh, KB
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2002, 10 (01) : 27 - 35
  • [44] Transfer Calibration for Alcohol Determination Using Temperature-Induced Shortwave Near Infrared Spectra
    Fu Qing-bo
    Suo Hui
    He Xin-ping
    Cong Yu-liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (08) : 2080 - 2084
  • [45] Experimental design procedures in the calibration of quality parameters of alfalfa pellets from near infrared spectra
    Gatius, F
    Ferran, J
    Puy, J
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (03) : 167 - 176
  • [46] Near infrared spectroscopy (NIRS) calibration equations to predict nutritional quality parameters of tropical forages
    Lucia Molano, Martha
    Lucia Cortes, Maria
    Avila, Patricia
    Martens, Siriwan D.
    Stella Munoz, Luz
    TROPICAL GRASSLANDS-FORRAJES TROPICALES, 2016, 4 (03): : 139 - 145
  • [47] Comparative study on serum iron determination by different methods
    Suwansaksri, J
    Sookarun, S
    Wiwanitkit, V
    Boonchalermvichian, C
    Nuchprayoon, I
    TOXICOLOGY, 2001, 164 (1-3) : 227 - 227
  • [48] Respiration index determination: A comparative study of different methods
    Adani, F
    Gigliotti, G
    Valentini, F
    Laraia, R
    COMPOST SCIENCE & UTILIZATION, 2003, 11 (02) : 144 - 151
  • [49] Determination of triglycerides in human plasma using near-infrared spectroscopy and multivariate calibration methods
    da Costa, PA
    Poppi, RJ
    ANALYTICA CHIMICA ACTA, 2001, 446 (1-2) : 39 - 47
  • [50] A COMPARISON OF METHODS FOR MOISTURE DETERMINATION OF FORAGES FOR NEAR-INFRARED REFLECTANCE SPECTROSCOPY CALIBRATION AND VALIDATION
    WINDHAM, WR
    ROBERTSON, JA
    LEFFLER, RG
    CROP SCIENCE, 1987, 27 (04) : 777 - 783