Vesical pacing: Pacing parameters required for normalization of vesical electric activity in patients with overactive bladder

被引:3
|
作者
Shafik, A
El Sibai, O
Shafik, AA
Ahmed, I
Mostafa, RM
机构
[1] Cairo Univ, Fac Med, Dept Surg & Expt Res, Cairo, Egypt
[2] Menoufia Univ, Fac Med, Dept Surg, Shibin Al Kawm, Egypt
[3] Benha Univ, Fac Med, Dept Physiol, Banha, Egypt
来源
关键词
pacing electrode; slow waves; action potentials; dysrhythmia;
D O I
10.2741/1280
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There are several modalities for the treatment of the overactive bladder (OAB), but the results may not be satisfactory. A recent study has demonstrated that the OAB has a dysrhythmic electric activity that seems to result from a disordered vesical pacemaker. We hypothesized that vesical pacing may correct the irregularities of the vesical electric waves and consequently normalize the vesical contractility. In this communication, we primarily defined the adequate pacing parameters required for correction of the vesical dysrhythmia. 36 patients with OAB were divided into a study group (22; 13 women; mean age 40.2 years) and a control group (14; 8 women; mean age 41.8 years). Ten healthy volunteers (6 women; mean age 39.8 years) were included in the study. Three 28-gauge cardiac pacing electrodes were hooked to the vesical mucosa: one (pacing) to the vault, and two (recording) to the lateral wall. Electric activity at rest and during stimulation of the pacing electrode was recorded in the study group and the healthy volunteers. In the control group, recording was done without pacing. Reproducible regular triphasic SWs were recorded from the 2 electrodes of the healthy volunteers with a similar pattern from the 2 electrodes of each individual subject. The optimal pacing parameters we determined were: an amplitude of 5 mA, a pulse width of 200 ms and a frequency of 20% higher than the frequency of the basal vesical waves. Vesical pacing effected a significant increase of waves' variables. The OAB patients exhibited a "dysrhythmic" wave pattern which was normalized during vesical pacing using the aforementioned pacing parameters. The optimal parameters required for vesical pacing of the dysrhythmic waves of the OAB were determined and succeeded in normalization of the vesical electric activity. Vesical pacing is suggested to be used as a therapeutic tool for the treatment of the OAB.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [21] Exploring patients' opinions of activity pacing and a new activity pacing questionnaire for chronic pain and/or fatigue: a qualitative study
    Antcliff, Deborah
    Keeley, Philip
    Campbell, Malcolm
    Woby, Steve
    McGowan, Linda
    [J]. PHYSIOTHERAPY, 2016, 102 (03) : 300 - 307
  • [22] CORRELATION OF OVERACTIVE BLADDER SYMPTOM SCORE, VOIDING DIARY AND URODYNAMIC PARAMETERS IN PATIENTS WITH OVERACTIVE BLADDER
    Song, Miho
    Chun, Jiyoun
    Han, Ji-Yeon
    Yoo, Dae Sun
    Lee, Kyu-Sung
    Choo, Myung-Soo
    Kim, Joon Chul
    Park, Won Hee
    Choi, Jong Bo
    [J]. NEUROUROLOGY AND URODYNAMICS, 2013, 32 (02) : 144 - 144
  • [23] CORRELATION OF OVERACTIVE BLADDER SYMPTOM SCORE, VOIDING DIARY AND URODYNAMIC PARAMETERS IN PATIENTS WITH OVERACTIVE BLADDER
    Song, M.
    Chun, J.
    Yoo, D. S.
    Han, J. Y.
    Chung, J. Y.
    Choo, M.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2012, 31 (06) : 999 - 1000
  • [24] Superselective vesical artery embolization versus intravesical formalin for intractable hematuria in patients with bladder cancer
    Sonmez, G.
    Tombul, S. Tolga
    Herdem, N.
    Demirtas, T.
    Tatlisen, A.
    Demirtas, A.
    [J]. ACTAS UROLOGICAS ESPANOLAS, 2022, 46 (01): : 35 - 40
  • [25] Comparison of electrical characteristics and pacing parameters of pacing different parts of the His-Purkinje system in bradycardia patients
    Xi Liu
    Min Gu
    Wei Hua
    Yiran Hu
    Hong-xia Niu
    Minsi Cai
    Nixiao Zhang
    Shu Zhang
    [J]. Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 175 - 183
  • [26] Biventricular pacing decreases sympathetic activity compared with right ventricular pacing in patients with depressed ejection fraction
    Hamdan, MH
    Zagrodzky, JD
    Joglar, JA
    Sheehan, CJ
    Ramaswamy, K
    Erdner, JF
    Page, RL
    Smith, ML
    [J]. CIRCULATION, 2000, 102 (09) : 1027 - 1032
  • [27] Comparison of electrical characteristics and pacing parameters of pacing different parts of the His-Purkinje system in bradycardia patients
    Liu, Xi
    Gu, Min
    Hua, Wei
    Hu, Yiran
    Niu, Hong-xia
    Cai, Minsi
    Zhang, Nixiao
    Zhang, Shu
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (01) : 175 - 183
  • [28] Correlation of the Overactive Bladder Symptom Score, and the Voiding Diary and Urodynamic Parameters in Patients with Overactive Bladder Syndrome
    Song, Miho
    Chun, Ji-Youn
    Yoo, Dae Sun
    Han, Ji-Yeon
    Choo, Myung-Soo
    [J]. LUTS-LOWER URINARY TRACT SYMPTOMS, 2014, 6 (03) : 180 - 184
  • [29] Impact of interventricular delay on repolarization parameters in patients with biventricular pacing
    Subramanian, Muthiah
    Yalagudri, Sachin
    Saggu, Daljeet
    Sridevi, Chennapragada
    Narasimhan, Calambur
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2020, 63 : 145 - 146
  • [30] Evaluation of right ventricular pacing parameters in patients with proliferative scar
    Veysel Kutay Vurgun
    Emir Baskovski
    Huseyin Goksuluk
    Nil Ozyuncu
    Turkan Seda Tan
    Ali Timucin Altin
    Basar Candemir
    Omer Akyurek