Detection of a slant crack in a rotor bearing system during shut-down

被引:15
|
作者
Sathujoda, Prabhakar [1 ,2 ]
机构
[1] Bennett Univ, Dept Mech, Aerosp Engn, Greater Noida, India
[2] Bennett Univ, Dept Mech, CONTACT Prabhakar Sathujoda, Aerosp Engn, Greater Noida, India
关键词
Rotor bearing system; slant crack; continuous wavelet transform critical speed mode shape; DYNAMIC ANALYSIS;
D O I
10.1080/15397734.2019.1707686
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The transient response of a slant-cracked rotor system during shut-down has been analyzed while it is decelerating through the critical speed. Vibration response has been simulated by using finite element method (FEM) for flexural vibrations. An unbalance force and a harmonically-varying torque is applied on the rotor system. Subharmonic frequency components at an interval frequency corresponding to torsional frequency were found in the frequency domain (Fast Fourier Transform (FFT) plot). These peaks are centered on the critical speed of the rotor system when a slant crack is present and can be used to detect the crack. The fundamental mode shapes of the rotor bearing systems are wavelet transformed to identify the crack location. A peak is observed at the crack location in the spatial variation of the wavelet-transformed fundamental mode shape. A few suggestions for the detection of slant cracks in the rotor during shut-down are described.
引用
收藏
页码:266 / 276
页数:11
相关论文
共 50 条
  • [1] FAULT TREE ANALYSIS OF CANDU SHUT-DOWN SYSTEM
    SHARMA, DD
    RAM, KS
    NUCLEAR ENGINEERING AND DESIGN, 1980, 61 (02) : 265 - 276
  • [2] Nonlinear responses analysis caused by slant crack in a rotor-bearing system
    Chen, Xuelian
    JOURNAL OF VIBROENGINEERING, 2016, 18 (07) : 4369 - 4387
  • [3] Corrosion product release during the shut-down of BWR's
    Schenker, E
    Loner, H
    Alder, HP
    Blaser, B
    Blaser, W
    WATER CHEMISTRY OF NUCLEAR REACTOR SYSTEMS 7, VOL 1, 1996, : 176 - 181
  • [4] PROCESS SHUT-DOWN SYSTEM FOR NORTH-SEA PLATFORM
    不详
    MEASUREMENT AND CONTROL, 1979, 12 (04): : 143 - 143
  • [5] Automatic laser shut-down system in optical fiber communication
    Zhang, Jie
    Ji, Yuefeng
    Guo, Lixin
    Li, Guorui
    Beijing Youdian Xueyuan Xuebao/Journal of Beijing University of Posts And Telecommunications, 1996, 19 (04): : 29 - 34
  • [6] Dynamic performance tests of bump-type gas foil journal bearing-rotor system in start-up and shut-down procedures
    Xu, Fang-Cheng
    Liu, Zhan-Sheng
    Ma, Rui-Xian
    Huang, Fei-Lin
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2014, 29 (01): : 216 - 224
  • [7] Asymmetry characteristic of tilting-pad thrust bearing during the start-up and shut-down process
    Wang, Zhanchao
    Guo, Fei
    Liu, Ying
    Liu, Xiangfeng
    Wang, Yuming
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2018, 70 (09) : 1806 - 1814
  • [8] HANFORD SAFEGUARD SYSTEM GUARANTEES SHUT-DOWN REACTOR STAYS THAT WAY
    GOLDSTEI.C
    NUCLEONICS, 1967, 25 (01): : 58 - &
  • [9] STABILITY AND DYNAMICS OF A ROTOR SYSTEM WITH A SLANT CRACK ON THE SHAFT
    Chu, Fulei
    Lin, Yanli
    8TH IFTOMM INTERNATIONAL CONFERENCE ON ROTOR DYNAMICS (IFTOMM ROTORDYNAMICS 2010), 2010, : 623 - 627
  • [10] The dynamic behavior of a rotor system with a slant crack on the shaft
    Lin, Yanli
    Chu, Fulei
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2010, 24 (02) : 522 - 545