Linear optics and coupling correction of ILSF storage ring lattice

被引:5
|
作者
Mashal, A. [1 ]
Kashani, F. D. [1 ]
Rahighi, J. [2 ]
机构
[1] IUST, Tehran, Iran
[2] Inst Res Fundamental Sci IPM, ILSF, Tehran, Iran
关键词
Storage ring; Closed orbit; Beam dynamics; Lifetime;
D O I
10.1016/j.nima.2019.163180
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Iranian Light Source Facility (ILSF) is a 3 GeV synchrotron radiation facility, which is in the design stage. The ILSF storage ring design is based on a five-bend achromat lattice providing an ultralow horizontal beam emittance of 0.27 nm-rad. Inevitable errors like imperfection of magnetic field and misalignment of magnets will introduce various destructive effects on the performance of the machine. The possibility of correcting the errors should be thoroughly examined before settling the design. In this paper, we have tried to estimate the errors as realistic as possible based on the results obtained from the simulation of the elements and the accuracy of the predicted equipment for fabrication and alignment. The influence of errors on the lattice is investigated. Closed orbit distortion, beta beating and betatron coupling are corrected and improvement made in the lattice functions and machine performance will be presented.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Analysis and correction of linear optics errors, and operational improvements in the Indus-2 storage ring
    Husain, Riyasat
    Ghodke, A. D.
    CHINESE PHYSICS C, 2017, 41 (08)
  • [12] Analysis and correction of linear optics errors, and operational improvements in the Indus-2 storage ring
    Riyasat Husain
    A.D.Ghodke
    Chinese Physics C, 2017, (08) : 134 - 146
  • [13] Coupling measurement and correction at the SSRF storage ring
    ManZhou Zhang
    Jie Hou
    HaoHu Li
    Science China Physics, Mechanics and Astronomy, 2011, 54 : 201 - 206
  • [14] Coupling measurement and correction at the SSRF storage ring
    ZHANG ManZhou*
    Science China(Physics,Mechanics & Astronomy), 2011, (S2) : 201 - 206
  • [15] Coupling measurement and correction at the SSRF storage ring
    Zhang ManZhou
    Hou Jie
    Li HaoHu
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2011, 54 : S201 - S206
  • [16] Linear and nonlinear optics studies in the ANKA storage ring
    Müller, AS
    Birkel, I
    Huttel, E
    Pérez, F
    Pont, M
    Rossmanith, R
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3273 - 3275
  • [17] Linear optics and coupling correction with closed orbit modulation
    Huang, Xiaobiao
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2021, 24 (07)
  • [18] Measurement and correction of linear optics and coupling at tevatron complex
    Lebedev, V
    Nagaslaev, V
    Valishev, A
    Sajaev, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 558 (01): : 299 - 302
  • [19] The impact of the resistive-wall impedance on the ILSF storage ring
    Khosravi, N.
    Dastan, S.
    Akhyani, M.
    Ahmadi, E.
    IPAC23 PROCEEDINGS, 2024, 2687
  • [20] Beam optics correction in the PLS-II storage ring
    B. H. Oh
    J. Lee
    M. Yoon
    S. H. Shin
    Journal of the Korean Physical Society, 2013, 63 : 1268 - 1273