Multichannel wearable fNIRS-EEG system for long-term clinical monitoring

被引:54
|
作者
Kassab, Ali [1 ]
Le Lan, Jerome [2 ]
Tremblay, Julie [3 ]
Vannasing, Phetsamone [3 ]
Dehbozorgi, Mahya [2 ]
Pouliot, Philippe [2 ,5 ]
Gallagher, Anne [3 ]
Lesage, Frederic [2 ]
Sawan, Mohamad [2 ]
Dang Khoa Nguyen [1 ,4 ]
机构
[1] Univ Montreal, Res Ctr, Ctr Hosp Univ Montreal, Montreal, PQ H2X 0A9, Canada
[2] Ecole Polytech Montreal, Dept Elect Engn, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Res Ctr, Hop St Justine, Montreal, PQ H3T 1C4, Canada
[4] Ctr Hosp Univ Montreal, Dept Neurol, Hop Notre Dame, Montreal, PQ H2L 4M1, Canada
[5] Montreal Heart Inst, Res Ctr, Montreal, PQ H1T 1C8, Canada
基金
加拿大健康研究院;
关键词
portable near-infrared spectroscopy; electroencephalography; cerebral hemodynamics; functional brain imaging and monitoring; limb-shaking transient ischemic attacks; epilepsy; NEAR-INFRARED SPECTROSCOPY; VISUAL-EVOKED-POTENTIALS; ANEURYSMAL SUBARACHNOID HEMORRHAGE; CEREBRAL BLOOD OXYGENATION; FUNCTIONAL MRI; HUMAN-BRAIN; OPTICAL PATHLENGTH; LANGUAGE DOMINANCE; INVOS; 3100; NIRS;
D O I
10.1002/hbm.23849
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Continuous brain imaging techniques can be beneficial for the monitoring of neurological pathologies (such as epilepsy or stroke) and neuroimaging protocols involving movement. Among existing ones, functional near-infrared spectroscopy (fNIRS) and electroencephalography (EEG) have the advantage of being noninvasive, nonobstructive, inexpensive, yield portable solutions, and offer complementary monitoring of electrical and local hemodynamic activities. This article presents a novel system with 128 fNIRS channels and 32 EEG channels with the potential to cover a larger fraction of the adult superficial cortex than earlier works, is integrated with 32 EEG channels, is light and battery-powered to improve portability, and can transmit data wirelessly to an interface for real-time display of electrical and hemodynamic activities. A novel fNIRS-EEG stretchable cap, two analog channels for auxiliary data (e.g., electrocardiogram), eight digital triggers for event-related protocols and an internal accelerometer for movement artifacts removal contribute to improve data acquisition quality. The system can run continuously for 24h. Following instrumentation validation and reliability on a solid phantom, performance was evaluated on (1) 12 healthy participants during either a visual (checkerboard) task at rest or while pedalling on a stationary bicycle or a cognitive (language) task and (2) 4 patients admitted either to the epilepsy (n=3) or stroke (n=1) units. Data analysis confirmed expected hemodynamic variations during validation recordings and useful clinical information during in-hospital testing. To the best of our knowledge, this is the first demonstration of a wearable wireless multichannel fNIRS-EEG monitoring system in patients with neurological conditions. Hum Brain Mapp 39:7-23, 2018. (c) 2017 Wiley Periodicals, Inc.
引用
收藏
页码:7 / 23
页数:17
相关论文
共 50 条
  • [31] LONG-TERM EEG MONITORING IN EPILEPSY: IS IT WORTH THE EFFORT?
    Powell, H. W. R.
    Yogarajah, M.
    Duncan, J.
    Smith, S.
    Sisodiya, S. M.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2009, 80 (01): : 97 - 97
  • [32] Temporal Convolutional Network-Enhanced Real-Time Implicit Emotion Recognition with an Innovative Wearable fNIRS-EEG Dual-Modal System
    Chen, Jiafa
    Yu, Kaiwei
    Wang, Fei
    Zhou, Zhengxian
    Bi, Yifei
    Zhuang, Songlin
    Zhang, Dawei
    ELECTRONICS, 2024, 13 (07)
  • [33] CLINICAL APPLICATION OF COMPRESSED SPECTRAL ARRAY IN LONG-TERM EEG MONITORING OF COMATOSE PATIENTS
    BRICOLO, A
    TURAZZI, S
    FACCIOLI, F
    ODORIZZI, F
    SCIARRETTA, G
    ERCULIANI, P
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 45 (02): : 211 - 225
  • [34] A Wearable Stethoscope for Long-Term Ambulatory Respiratory Health Monitoring
    Yilmaz, Gurkan
    Rapin, Michael
    Pessoa, Diogo
    Rocha, Bruno M.
    de Sousa, Antonio Moreira
    Rusconi, Roberto
    Carvalho, Paulo
    Wacker, Josias
    Paiva, Rui Pedro
    Chetelat, Olivier
    SENSORS, 2020, 20 (18) : 1 - 14
  • [35] Long-term thermal comfort monitoring using wearable devices
    Gnecco, Veronica Martins
    Pigliautile, Ilaria
    Pisello, Anna Laura
    PROCEEDINGS OF 2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR LIVING ENVIRONMENT (IEEE METROLIVEN 2022), 2022, : 13 - 17
  • [36] 104 Automated Analysis of Long-Term Continuous Multichannel Eeg in Premature Infants
    E Schumacher
    Å Westwik
    P G Larsson
    R Lindemann
    J Westwik
    T Stiris
    Pediatric Research, 2010, 68 : 55 - 56
  • [37] DISPOSABLE ELECTRODE SYSTEM FOR EEG MONITORING DURING LONG-TERM SPACE FLIGHT.
    Frost Jr., James D.
    Shumate, William E.
    1600, Acad Press, Inc, New York, NY
  • [38] A Low Power System With EEG Data Reduction for Long-Term Epileptic Seizures Monitoring
    Imtiaz, Syed Anas
    Iranmanesh, Saam
    Rodriguez-Villegas, Esther
    IEEE ACCESS, 2019, 7 (71195-71208): : 71195 - 71208
  • [39] Forty EEG Electrode Array For Long-Term Video-EEG Monitoring
    Dunkan, L.
    Skaarup, N. C.
    Cho, J. -H.
    Scherg, M.
    Beniczky, S.
    EPILEPSIA, 2019, 60 : 86 - 86
  • [40] ANALYSIS OF PSEUDOSEIZURES IN EPILEPTIC PATIENTS WITH ICTAL EEG AND LONG-TERM EEG MONITORING
    TAMAI, K
    TAKEUCHI, A
    IAI, M
    AIHARA, M
    TANABE, Y
    BRAIN & DEVELOPMENT, 1987, 9 (02): : 159 - 159