Detection of the Third Heart Sound Using Hilbert-Huang Transform

被引:0
|
作者
Tseng, Y. L. [1 ]
Lin, K. S. [2 ]
Ko, P. Y. [2 ]
Jaw, F. -S. [1 ]
机构
[1] Natl Taiwan Univ, Inst Biomed Engn, Taipei 10764, Taiwan
[2] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
关键词
the third heart sound; Hilbert-Huang transform;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Existence of the third heart sound is an indication of heart failure. In this paper, a novel method is proposed to detect the presence of the third heart sound. A time-frequency analysis method, Hilbert-Huang transform, was used to decompose the signal adaptively and to acquire the instantaneous frequency. Further extraction of the maximal instantaneous frequency and its magnitude is performed to a heart sound signal to distinguish the third heart sound which is usually with lower frequency as well as lower amplitude. A frequency-magnitude distribution was plotted, and the results showed the difference between a normal heart sound and a heart sound with the third heart sound.
引用
收藏
页码:1811 / 1813
页数:3
相关论文
共 50 条
  • [41] Structural damage detection based on improved Hilbert-Huang transform
    Ren, Yi-Chun
    Weng, Pu
    Zhendong yu Chongji/Journal of Vibration and Shock, 2015, 34 (18): : 195 - 199
  • [42] Research on Pipeline Leak Detection Based on Hilbert-Huang Transform
    Zhang Shuqing
    Gao Tianye
    Han Xu
    Jia Jian
    Wang Zhongdong
    2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 3, PROCEEDINGS, 2009, : 500 - 503
  • [43] A normalized Hilbert-Huang transform technique for bearing fault detection
    Osman, Shazali
    Wang, Wilson
    JOURNAL OF VIBRATION AND CONTROL, 2016, 22 (11) : 2771 - 2787
  • [44] Heart Rate Variability Signal Processing for Safety Driving Using Hilbert-Huang Transform
    Hsu, Chih-Ming
    Lian, Feng-Li
    Huang, Cheng-Ming
    Chou, Jen-Hsiang
    2014 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2014), 2014, : 434 - 437
  • [45] Hilbert-Huang Transform for Analysis of Heart Rate Variability in Cardiac Health
    Li, Helong
    Kwong, Sam
    Yang, Lihua
    Huang, Daren
    Xiao, Dongping
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2011, 8 (06) : 1557 - 1567
  • [46] Underwater sound classification based on Gammatone filter bank and Hilbert-Huang transform
    Zeng, Xiangyang
    Wang, Shuguang
    2014 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (ICSPCC), 2014, : 707 - 710
  • [47] Analysis of Nonstationary Wind Fluctuations Using the Hilbert-Huang Transform
    XU Jing-Jing
    HU Fei
    Atmospheric and Oceanic Science Letters, 2014, 7 (05) : 428 - 433
  • [48] Analysis of partial discharge signal using the Hilbert-Huang transform
    Wang, Xiaodong
    Li, Baoqing
    Liu, Zhiwei
    Roman, Harry T.
    Russo, Onofrio L.
    Chin, Ken K.
    Farmer, Kenneth R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1063 - 1067
  • [49] Underwater target feature extraction using Hilbert-Huang transform
    Li, Xiu-Kun
    Xie, Lei
    Qin, Yu
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2009, 30 (05): : 542 - 546
  • [50] Interpretation of mechanical signals using an improved Hilbert-Huang transform
    Yang, Wen-Xian
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2008, 22 (05) : 1061 - 1071