An Adaptive Element-Level Impedance-Matched ASIC With Improved Acoustic Reflectivity for Medical Ultrasound Imaging

被引:3
|
作者
Rezvanitabar, Ahmad [1 ]
Kilinc, M. Sait [1 ]
Tekes, Coskun [2 ]
Arkan, Evren F. [3 ]
Ghovanloo, Maysam [4 ]
Degertekin, F. Levent [1 ,3 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Kennesaw State Univ, Dept Elect & Comp Engn, Marietta, GA 30033 USA
[3] Georgia Inst Technol, GWW Sch Mech Engn, Atlanta, GA 30332 USA
[4] Bion Sci Inc, Atlanta, GA 30316 USA
基金
美国国家卫生研究院;
关键词
Acoustics; Transducers; Reflectivity; Impedance; Capacitors; Bandwidth; Integrated circuit modeling; Acoustic reflectivity; ASIC; array uniformity; capacitive cancellation; capacitive micromachined ultrasonic transducer (CMUT); crosstalk; HV pulser; impedance matching; negative capacitance (NC); ultrasound transceiver (US-TRX); CMUT; TRANSDUCER; CROSSTALK; ARRAY; MODEL; SYSTEM; ICE;
D O I
10.1109/TBCAS.2022.3181157
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an active impedance matching scheme that tries to optimize electrical power transfer and acoustic reflectivity in ultrasound transducers. Leveraging negative capacitance-based impedance matching would potentially improve the bandwidth and electrical power transfer while minimizing acoustic reflection of transducer elements and improve uniformity while reducing acoustic crosstalk of transducer arrays. A 16-element transceiver front-end is designed which employs an element-level active capacitive impedance cancellation scheme using an element-level negative impedance converter. The ASIC fabricated in 180-nm HVBCD technology provides high-voltage pulses up to 60 V consuming 3.6 mW and occupying 2.5 mm(2). The front-end ASIC is used with a 1-D capacitive micromachined ultrasonic transducer (CMUT) array and its acoustical reflectivity reduction and imaging capabilities have successfully been demonstrated through pulse-echo measurements and acoustic imaging experiments.
引用
收藏
页码:492 / 501
页数:10
相关论文
共 4 条
  • [1] An Ultrasound Imaging Front-End System-on-a-Chip with Element-Level Impedance Matching for Acoustic Reflectivity Reduction
    Rezvanitabar, Ahmad
    Kilinc, M. Sait
    Tekes, Coskun
    Arkan, Evren F.
    Ghovanloo, Maysam
    Degertekin, F. Levent
    2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,
  • [2] An Ultrasound Receiver With Bandwidth-Enhanced Current Conveyor and Element-Level Ultrasound Transmitter for Ultrasound Imaging Systems
    Yun, Gichan
    Jeong, Kyeongwon
    Choi, Haidam
    Nam, Seunghyun
    Oh, Chaerin
    Lee, Hyunjoo Jenny
    Ha, Sohmyung
    Je, Minkyu
    IEEE SOLID-STATE CIRCUITS LETTERS, 2024, 7 : 98 - 101
  • [3] A 1.54mW/Element 150pm-Pitch-Matched Receiver ASIC with Element-Level SAR/Shared-Single-Slope Hybrid ADCs for Miniature 3D Ultrasound Probes
    Li, Jing
    Chen, Zhao
    Tan, Mingliang
    van Willigen, Douwe
    Chen, Chao
    Chang, Zu-yao
    Noothout, Emile
    de Jong, Nico
    Verweij, Martin
    Pertijs, Michiel
    2019 SYMPOSIUM ON VLSI CIRCUITS, 2019, : C220 - C221
  • [4] Ultrasound-Driven Highly Stable Implantable Triboelectric Nanogenerator with Human-Tissue Acoustic Impedance-Matched Polyether Ether Ketone
    Jeon, Sera
    Meng, Xiangchun
    Rubab, Najaf
    Kim, Dabin
    Mo, Hyeon
    Xiao, Xiao
    Park, Min Jae
    Cho, Daniel Sanghyun
    Kim, Seong Min
    Choi, Byung-Ok
    Kim, Sang-Woo
    ADVANCED MATERIALS TECHNOLOGIES, 2024, 9 (21):