Magnetoacoustic tomography with magnetic induction: A rigorous theory

被引:39
|
作者
Ma, Qingyu [1 ]
He, Bin [1 ]
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
关键词
electrical impedance imaging; magnetic induction; magnetoacoustic (MA) generation; tomography;
D O I
10.1109/TBME.2007.912674
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this letter, we have proposed a new theory on mechanism of the magnetoacoustic (MA) signal generation with magnetic induction for an object with an arbitrary shape. An object under a static magnetic field emits acoustic signals when excited by a time-varying magnetic field, and the acoustic waveform is mainly generated at the conductivity boundaries within the object. The proposed theory on the MA tomography with magnetic induction produced highly consistent results among computational and experimental paradigms in a two-layer sample phantom and suggested the potential applications for bioimpedance imaging.
引用
收藏
页码:813 / 816
页数:4
相关论文
共 50 条
  • [31] Image Reconstruction in Magnetoacoustic Tomography With Magnetic Induction With Variable Sound Speeds
    Zhang, Wei
    Ma, Ren
    Zhang, Shunqi
    Yin, Tao
    Liu, Zhipeng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (12) : 2585 - 2594
  • [32] Simulation Study on Forward Problem of Magnetoacoustic Tomography with Magnetic Induction Based on Magnetic Nanoparticles
    Yan, Xiaoheng
    Pan, Ye
    Zhang, Ying
    Guang, Sichen
    PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2019, 87 : 75 - 80
  • [33] Acoustic Vector Tomography and its Application to Magnetoacoustic Tomography with Magnetic Induction (MAT-MI)
    Li, Xia
    Xia, Rongmin
    He, Bin
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5834 - 5836
  • [34] A Forward Solution of Acoustic Inhomogeneity in Magnetoacoustic Tomography with Magnetic Induction Base on GFEM
    Zhang, Shuai
    Li, Wenlong
    Li, Jiawang
    Yang, Hongshuang
    Hou, Wanjiao
    Xu, Guizhi
    Yan, Weili
    2016 IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (CEFC), 2016,
  • [35] Simulation of magnetoacoustic tomography with magnetic induction images of metal sheet with anisotropic conductivity
    Sun, Zheng
    Liu, Sijia
    Shengxue Xuebao/Acta Acustica, 2020, 45 (02): : 215 - 226
  • [37] Magnetoacoustic Tomography With Magnetic Induction: Bioimepedance Reconstruction Through Vector Source Imaging
    Mariappan, Leo
    He, Bin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (03) : 619 - 627
  • [38] Simulation Research of Limited-View Magnetoacoustic Tomography With Magnetic Induction Methods
    Zhang S.
    Li Z.-X.
    Li W.-L.
    Zhou Z.-Y.
    Zhao M.-K.
    Xu G.-Z.
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2019, 39 : 168 - 175
  • [39] Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) for Electrical Conductivity Imaging
    Li, Xu
    He, Bin
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3173 - 3176
  • [40] Simulation Research on Magnetoacoustic Concentration Tomography with Magnetic Induction Based on Uniaxial Anisotropy of Magnetic Nanoparticles
    Yan X.
    Hu Y.
    Chen W.
    Shi X.
    Pan Y.
    Xu Z.
    Progress In Electromagnetics Research C, 2021, 116 : 221 - 233